User manual ZIBRO SRE168E

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO SRE168E. We hope that this ZIBRO SRE168E user guide will be useful to you.


ZIBRO SRE168E : Download the complete user guide (507 Ko)

You may also download the following manuals related to this product:

   ZIBRO SRE168E (572 ko)
   ZIBRO SRE168E (1556 ko)
   ZIBRO SRE168E (1556 ko)
   ZIBRO SRE168E (1556 ko)
   ZIBRO SRE168E (1556 ko)
   ZIBRO SRE168E (1556 ko)
   ZIBRO SRE168E (502 ko)

Manual abstract: user guide ZIBRO SRE168E

Detailed instructions for use are in the User's Guide.

[. . . ] If you change to another brand and/or type of parrafin oil, you must first finish up all the remaining fuel in the heater. SAVE key Indicator lights EXTENSION Connection weektimer Air quality control system 4 51 WHAT YOU NEED TO KNOW IN ADVANCE ALWAYS MAKE SURE THAT THERE IS SUFFICIENT VENTILATION This heater is equipped with an air quality control system . When there is insufficient ventilation in the room or when the heater is being used in a room which is too small, the heater will shut off automatically. For comfortable and safe heating ensure that there is sufficient ventilation. Note: To avoid unexpected shut off, we recommend to put a door or window ajar when the heater is operating. [. . . ] In order to switch on the timer, the correct time must have been set (refer to Section C) and the heater should be off. Follow the procedure below: 1 Press the button and then the TIMER key immediately after that. The TIMER light and the information display will start blinking. 2 Use the adjustment keys to set the time at which the heater must ignite. Use the key on the left (Nhour) to set the hours and the key on the right (Mmin. ) to set the minutes (interval of 5 minutes). 3 After approximately 10 seconds the information display will show CLOCK again and the TIMER indicator light will light up, indicating that the timer H: The TIMER indicator light indicates that the timer function has been switched on. function has been activated (Fig. 4 The timer will ensure that the room will have been heated to approximately the required temperature at the set time. G H When you want to switch off the heater and ignite it again with the timer, all you have to do is press the TIMER key (refer to Section G). Press the button once to clear the timer setting. If you would like more extensive timer possibilities, we advise you to procure the Zibro weektimer. This timer is easy to connect with your Zibro Heater, see . SWITCHING OFF THE HEATER There are two ways to switch off the heater. 2 Press the TIMER key , when you want to switch off the heater and ignite it again with the timer the next time. This not only switches off the heater, but it also activates the timer function. You can change the required time with the adjustment keys (refer to Section F). THE INFORMATION DISPLAY The information display not only serves as an indicator of the (set) time and temperature (Sections C, E, and F), it also indicates any malfunctioning of the heater. The code on the information display tells you what is the matter: 4 55 CODE In case of any malfunctioning the information display will tell you what is the matter. efefeeee- 0 0 1 1 2 5 6 7 e- 8 e- 9 --blinking : -(& FUEL-light) INFORMATION Temperature within the heater too high. The heater has been in operation continuously for a period of 91 hours and has turned itself off automatically. Ventilate better. --blinking : -(& VENT-light) e-11 (& blinking VENT-light) Always contact your Zibro dealer for any malfunctioning not listed above. AUTOMATIC DEACTIVATION This heater is fitted with a safety system that ensures that it switches off automatically after 91 hours continuous operation. 'SAVE' is an economy setting, which you can use when, for instance, you are not present in the room or to keep it frost-free. THE 'FUEL' INDICATOR LIGHT When the indicator light FUEL lights up, it means that there is only fuel left for 10 more minutes. The count-down of the remaining heating time can be seen in the information display (Fig. Now you have two options: you remove the fuel tank and refill it outside the living room (section B) or you push the button EXTENSION . By pushing this button, the remaining heating time will extend to 90 minutes. At the arrival of 10, you will hear an alarmsignal every two minutes, warning you to refill the removable tank. The fuel indicator light will blink, while four lines (--:--) are blinking in the information display. Once the heater has used up all its fuel and extinguished, it will take some time, after the refill, before the heater is completely ready for use again. K: When the FUEL indicator light is lit, the information display will show the number of minutes of fuel left in the tank. THE 'VENT' INDICATOR LIGHT When there is insufficient ventilation in the room, an intermittent buzzer will be heard (approximately once each 30 seconds) and the VENT indicator will be lit. When this signal is given, ensure that the ventilation of the room is improved (e. g. by opening a door or window a little more), to avoid that the heater shuts off. [. . . ] Always make sure that there is sufficient ventilation. 5 6 7 8 9 10 Defective electrical devices and batteries must be kept separate from household waste. Ask you local council or dealer for expert advice on recycling. 4 59 AFAQ AFNOR CERTIFICATION 11, AVENUE FRANCIS DE PRESSENSE 93571 SAINT-DENIS LA PLAINE CEDEX FICHE INFORMATIVE La marque NF garantit la qualit de cet article suivant les normes franaises et Rgles de certification de l'application NF 128 CHAUFFAGES MOBILES A COMBUSTIBLE LIQUIDE NF 128 02 / 02 CONFORME A LA NORME NF D 35-300 ET AUX SPECIFICATIONS COMPLEMENTAIRES DEFINIES PAR LES REGLES DE CERTIFICATION DE L'APPLICATION NF 128 PRINCIPALES CARACTERISTIQUES CERTIFIEES: Scurit du dispositif d'allumage Dbit calorifique Efficacit des dispositifs de scurit Stabilit Contrle de la teneur en NOx dans les produits de combustion Contrle de la qualit de la combustion (absence de CO) Endurance Intermittence CONSEILS D'UTILISATION ET D'ENTRETIEN Se reporter la notice jointe l'appareil et la plaque de scurit sur l'appareil Rfrence et numro de lot ou de srie de l'article : se reporter au produit Distributed in Europe by: PVG International B. V. P. O. Box 96, 5340 AB OSS Pays-Bas Tl. : +31 (0) 412 694670 En cas d'insatisfaction, consultez d'abord : En France: PVG France SARL 4, Rue Jean Siblius, B. P. 185 76410 SOTTEVILLE SOUS LE VAL Tl. : 02. 32. 96. 07. 47 Fax: 02. 32. 96. 07. 77 Si une difficult subsistait, vous pouvez crire au LNE LABORATOIRE NATIONAL DE MTROLOGIE ET D'ESSAIS Division Certification plurisectorielle 1, Rue Gaston Boisier - 75724 PARIS CEDEX 15 DISTRIBUTED IN EUROPE BY PVG INTERNATIONAL b. v. i STERREICH PVG Austria VertriebsgmbH Salaberg 49 3350 HAAG tel: +43 7434 44867 fax: +43 7434 44868 email: pvgaustria@zibro. com e BELGI PVG Belgium NV/SA Industrielaan 55 2900 SCHOTEN tel: +32 3 326 39 39 fax: +32 3 326 26 39 email: pvgbelgium@zibro. com q SCHWEIZ PVG Schweiz AG Salinenstrasse 63 4133 PRATTELN tel: +41 61 337 26 51 +41 61 337 26 78 fax: email: pvgint@zibro. com 2 DEUTSCHLAND PVG Deutschland GmbH Siemensstrasse 31 47533 KLEVE tel: 0800 - 9427646 fax: +31 (0)412 648 385 email: pvgdeutschland@zibro. com 6 DANMARK Appliance A/S Blovstroed Teglvaerksvej 3 DK-3450 ALLEROED tel: +45 70 205 701 fax: +45 70 208 701 email: appliance@appliance-group. com 5 ESPAA PVG Espaa S. A. San Jos de Valderas II Comunidad "La Alameda" C/ Aurora Boreal, 19 28918 LEGANS (Madrid) tel: +34 91 611 31 13 fax: +34 91 612 73 04 email: pvgspain@zibro. com 3 FRANCE PVG France SARL 4, Rue Jean Siblius B. P. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO SRE168E




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO SRE168E will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.