User manual ZIBRO S3248

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZIBRO S3248. We hope that this ZIBRO S3248 user guide will be useful to you.


ZIBRO S3248 : Download the complete user guide (8624 Ko)

Manual abstract: user guide ZIBRO S3248

Detailed instructions for use are in the User's Guide.

[. . . ] Læs denne brugsanvisning, før du tager airconditionanlægget i brug, for at sikre længst mulig levetid for anlægget. Dette produkt er beregnet til brug som et airconditionanlæg i private hjem og er kun egnet til brug i tørre omgivelser, under almindelige forhold i private hjem, indendørs i stuer, køkkener eller i garager. € Tryk tre gange på knappen for at slukke for airconditionanlægget. Knappen Mode (Indstilling): Hver gang du trykker på knappen, skiftes der tilstand i rækkefølgen auto, køling, affugtning, varme og ventilator som vist på nedenstående figur: AUTO KØLING AFFUGTNING VARME VENTILATOR ቤ ብ ቦ Knappen + : Tryk på denne knap for at øge indstillingen for indendørstemperaturen til 30 ºC. [. . . ] Wait for one second and the digital display area will show the temperature again. The "TIMER ON" indicator remains on and this function is activated. Off 6h Combined timer TIMER ON OFF (setting both ON and OFF timers simultaneously) TIMER OFF --> TIMER ON (On --> Stop --> Start operation) On On Set 2h Stop 10 h This feature is useful when you want to stop the air conditioner after you go to bed, and start it again in the morning when you wake up or when you return home. Example: To stop the air conditioner 2 hours after setting and start it again 10 hours after setting. Press the TIMER ON button again to display 10h on the TIMER ON display 5. Wait for one second and the digital display area will show the temperature again. € If the same time is set for both START and STOPPING settings, the stopping time will automatically increase 0. 5hr (the set time displays less than 10hr) or one hour (the set time displays 10hr or more). € To change the Timer on/off time, just press the corresponding TIMER button and reset the time. € Protect the remote controller from high temperatures and exposure to radiation. € Keep the indoor receiver out of direct sunlight or the air conditioner may malfunction. Qxd:man_S18xx 05-03-13 16:27 Page 123 F OPTIMAL OPERATION To achieve optimal performance, please note the following: • • • • • Adjust the air flow direction correctly so that it is not directly directed to people. Use TIMER ON button on the remote controller to select a time you want to start your air conditioner. Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running. Also the air stream must be allowed to reach the air conditioner unhindered. € • Clean the air filter periodically, otherwise cooling or heating performance may be reduced. G ADJUSTING AIR FLOW DIREC TION • • • Adjust the air flow direction properly otherwise, it might cause discomfort or cause uneven room temperatures. Adjust the horizontal louver using button ቩ on the remote controller. Adjusting the horizontal Air Flow Direction (up - down) The air conditioner automatically adjusts the horizontal air flow direction in accordance with the operating mode. To set the horizontal air flow direction Perform this function while the unit is in operation. Keep pressing the AIR DIRECTION button ቩ on the remote controller to move the louver to the desired direction. € • Adjust the horizontal air flow direction to the desired direction. [. . . ] Damage to units which are mounted, connected and/or disconnected not following local law and/or legislation and/or not following the guidelines in this manual is not covered by the guarantee conditions applicable to this product. Consult your dealer for repairs if these instructions do not provide a solution. Make sure that in the unlikely case of needed disconnection, that disconnection is always done by qualified, authorized personnel and according to your local laws and legislation. 6 A A A+ A+ 3100 (880 - 4040) 3100 (850 - 3920) 4800 (1470 - 6150) 4500 (1320 - 5530) Wall mounted split Wall mounted split Wall mounted split Wall mounted split S 3231 Type air-conditioner Cooling capacity* EE Class* Average season SEER* Heating capacity* Heating performance average season SCOP* Dehumidifying capacity (at 32°C/80%) ** / *** L / 24 h kW kW kWh V / Hz / Ph A A m3/h m3 W/A/C Rotary 3 ºC ºC Electronic remote Y -15 - +30 0 - 50 60-85 500/450/400 9 4/4 230~ / 50 / 1 165 / 1187 0. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZIBRO S3248




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZIBRO S3248 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.