User manual ZEKTOR PROWLER 8X8 V1.6

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZEKTOR PROWLER 8X8. We hope that this ZEKTOR PROWLER 8X8 user guide will be useful to you.


ZEKTOR PROWLER 8X8 V1.6: Download the complete user guide (539 Ko)

You may also download the following manuals related to this product:

   ZEKTOR PROWLER 8X8 V1.7 (550 ko)

Manual abstract: user guide ZEKTOR PROWLER 8X8V1.6

Detailed instructions for use are in the User's Guide.

[. . . ] Prowler 8x8 Clarity Elite 8x8 Serial & TCP/IP Protocol Component Video / CAT5/6/7 Audio Matrix Switches (For Prowler 8x8 and Clarity Elite 8x8 firmware Versions 1. 19 and above. ) History 2010-07-18 Version 1. 6 · Added DUPZ (Duplicate Zone) command. 2010-06-25 Version 1. 5c · Fixed BLZ (Balance) command description. 2 Clarity Elite 8x8 User Guide, Version 1. 6, 7/18/10 RS-232 / TCP/IP Port Hardware . 4 Timing information (unless specified otherwise by a command's description). 15 `Q', `QSZ', `QMZ', `QDZ' Query Status Commands . [. . . ] Command format: ^VMAZ @zone, @zone, maxVol ^VMAZ @zone, +step$ ^VMAZ @zone, -step$ ^VMAZ ?$ ^VMAZ @zone, @zone, ?$ Set the minimum volume of a zone or zones. Read current minimum setting(s) of given zone(s). Response Strings: ^=VMAZ @zone, minvol$ Where: @zone = One (or more) zones to be affected. Range is `minVol'+99 - 248. The gain command is given in 0. 5dB steps and uses an offset of 200 to indicate a gain of 0. 0dB. The minimum and maximum volume settings must have at least a 49. 5dB (99 steps) difference between them. Any attempt to set the maximum volume closer than 99 steps of the minimum, will result in a setting of exactly 99 steps above the minimum volume setting. `VPZ' Set Zone's Volume as a Percentage The Clarity Elite 8x8 or Prowler 8x8 can have their volumes adjusted as a percentage instead of an dB level. The VPZ command always uses a setting of 0 to 100, regardless of the minimum volume settings ("`VMIZ' Set Zone's Minimum Volume" on page 25) and the maximum volume settings ("`VMAZ' Set Zone's Maximum Volume" on page 26). Any value between 1 and 100 will be a percentage between minimum and maximum volume, to the nearest 0. 5dB. The format is: ^VPZ @zone, @zone, vol ^VPZ @zone, +step$ ^VPZ @zone, -step$ ^VPZ ?$ Set the volume of a zone or zones. In polled mode, reads current settings of all volume changes. 26 Clarity Elite 8x8 or Prowler 8x8 Serial Protocol, Version 1. 6, 7/18/10 Audio Control ^VPZ @zone, @zone, ?$ Read current volume settings of given zone(s). Response Strings: ^=VPZ @zone, vol$ Where: @zone = One (or more) zones to be affected. vol = Volume as a percentage: 0 through 100. To jump immediately to a new volume, the range is 0 to 100. To fade to a new level in a given time period the range is 1000 to 1100. Using the `+' or `-' modifiers to adjust the current volume level will disable the mute command. (See"`VMZ' Mute a Zone using Volume Control" on page 28. ) The current volume level used will be the value heard by the user (volume - mute attenutation). In other words, when adjusting the volume using +/- values, the volume will go up or down from the current value being heard by the user, regardless of the mute setting. The mute setting will be cancelled (unmuted), but will not have an affect on the volume level. The VMZ response will be sent to the controller to indicate mute was cancelled, along with the VPZ response to indicate the new unmuted volume level. Setting the volume without using the `+' or `-' modifiers will not have an affect on the mute setting. All the examples given in the set volume command (See "`VZ' Set Zone's Volume" on page 23) apply for the VPZ command as well. Simply substitute the VPZ for the VZ command and use values between 0 and 100. `VRT' Set Volume Ramp (Fade) Times The Clarity Elite 8x8 or Prowler 8x8 allows the volume to be ramped over time (fading), this command sets the ramp time and ramp speed used when fading volume. Fade volume at a controlled ramp speed. The VRT allows setting both of these. [. . . ] `K' Key Emulation This command allows access to the internal keyboard handling of the Clarity Elite 8x8 or Prowler 8x8. Each key generates a value upon being pressed, and a different value upon release. The Power toggle key also generates a unique value when held for 4 seconds, which is used to enter the setup mode. This command allows the controller to detect front panel key presses even when the front panel keys are disabled (See: "`KE' Key Enable / Disable" on page 45). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZEKTOR PROWLER 8X8




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZEKTOR PROWLER 8X8 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.