User manual ZANUSSI TD4100

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ZANUSSI TD4100. We hope that this ZANUSSI TD4100 user guide will be useful to you.


ZANUSSI TD4100 : Download the complete user guide (180 Ko)

You may also download the following manuals related to this product:

   ZANUSSI TD4100 (184 ko)
   ZANUSSI TD4100 (172 ko)
   ZANUSSI TD4100 (450 ko)
   ZANUSSI TD4100 (180 ko)
   ZANUSSI TD4100 (180 ko)
   ZANUSSI TD4100 (201 ko)
   ZANUSSI TD4100 (161 ko)
   ZANUSSI TD4100 (178 ko)
   ZANUSSI TD4100 (178 ko)

Manual abstract: user guide ZANUSSI TD4100

Detailed instructions for use are in the User's Guide.

[. . . ] If the machine is situated on a carpeted floor, please adjust the feet in order to allow air to circulate freely. It should have its own ventilation system which should not be joined with any other ventilation system connected to any other appliance. General safety It is dangerous to alter the specifications or attempt to modify this product in any way. Under no circumstances should you attempt to repair the machine yourself. Repairs carried out by inexperienced persons may cause injury or serious malfunctioning. [. . . ] Once in its permanent operating position, check that the dryer is absolutely level with the aid of a spirit level. If it is not, raise or lower the feet until it is. Fitting the vent hose To simplify the installation, there is a choice of vent outlets: one at the back, the others in the left and right-hand side. Connect the hose to whichever is the more convenient by pulling the ring nut (A) from the vent outlet at the back, screwing it on to the hose and pushing it firmly back into place. The unused vents should now be sealed with the special snap covers provided. A P1028 A P1027 Advice: If the hose is long and the room temperature low, the moisture might condense to water inside the hose. To prevent this water from Iying in the hose or flowing back into the tumble dryer, it is advisable to drill a small hole (dia. 3 mm) in the lowest point of the hose and to place a small container below it. (See picture, point B). P0046 P1056 B The feet must never be removed. Do not restrict the floor clearance through deeppile carpets, strips of wood or similar. This might cause heat build-up which would interfere with the operation of the appliance. Important When operating the tumble dryer, the room temperature must not exceed 35C, as it may affect the performance of the appliance. Once connected to the dryer, run the vent hose to the desired outlet point, ensuring that the run's overall length is less than 2 m, and that it contains no more than two bends. As to the outlet itself, if you have decided on a fixed wall/window grille, a good local builder's merchant should be able to supply you with the necessary fittings and installation advice. 7 ENGLISH It is important not to connect the vent hose to, for example, a cooker hood, or a chimney or flue pipe designed to carry the exhaust from a fuel burning appliance. - Refit the plastic plate (4) on the opposite side (Fig. - Refit the door by screwing in the two screws (1) which fasten the door to the cabinet (Fig. B). 2 3 P0283 1 4 A P0055 Note that to avoid condensation problems, it is essential that the dryer be fitted with the flexible hose to carry its "exhaust" at least beyond the kitchen units; preferable outside the kitchen. In order to prevent the appliance from overheating, it is important that the steam exhaust is unobstructed. Therefore, in case of a permanent hose fitted to an exterior wall or ceiling, it must be ensured an exhaust capacity of at least 150 m3/h. If the dryer is fitted next to kitchen units, make sure that the vent hose is not squashed. If the hose is partially squashed, drying efficiency will be reduced, resulting in longer drying times and higher energy consumption. If the hose is completely squashed, the safety cut-outs with which the machine is fitted may operate. P0748 4 1 2 3 B Electrical connection This machine is designed to operate on a 220-230 V, single-phase, 50 Hz supply. Check that your domestic electrical installation can take the maximum load required (2. 2 kW), also taking into account any other appliances in use. Connect the machine to an earthed socket, in accordance with current wiring regulations. The manufacturer declines any responsibility for damage or injury through failure to comply with the above safety precaution. Door reversal To make it easier to load or unload the laundry the door can be reversed. [. . . ] Always follow the instructions on garment labels: may be tumble dried normal drying (high temperature) delicate drying (low temperature) do not tumble dry Close pillowcases and covers with fasteners to prevent small laundry items getting tangled inside them. Do not over-dry laundry, this avoids creasing and saves energy. 12 Maintenance and Cleaning You must disconnect the appliance from the electricity supply, before you can carry out any cleaning or maintenance work. External cleaning Use only soap and water and then dry thoroughly. Important: do not use methylated spirit, diluents or similar products. Cleaning the door Clean periodically the interior part of the door to remove any fluff. Accurate cleaning ensures correct drying. P0328 Cleaning the filter Your dryer will only function well if the filter is clean. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ZANUSSI TD4100




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ZANUSSI TD4100 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.