User manual XTA DC1048 REV 1.00

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual XTA DC1048. We hope that this XTA DC1048 user guide will be useful to you.


XTA DC1048 REV 1.00: Download the complete user guide (11068 Ko)

Manual abstract: user guide XTA DC1048REV 1.00

Detailed instructions for use are in the User's Guide.

[. . . ] The Design House, Vale Business Park, Worcester Road, Stourport-on-Severn, Worcs. +44 1299 879969) Web: http://www. xta. co. uk x ta © XTA Electronics Ltd 2010 Designed & written by Waring Hayes 01/2010 If you have any comments or suggestions about this manual, please contact XTA at the address above, or email info@xta. co. uk Operator's Manual DC1048 Integrated Audio Management Page 1 Page 2 DC1048 Integrated Audio Management Operator's Manual Contents Important Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Thanks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Unpacking the unit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Front Panel Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] This is also added to the TX'ed message if enabled (see previous parameter) LCD Contrast: Adjust viewing angle of unit's display On Delay: Set a countdown time to delay audio fading up when unit is turned on. LED Timeout: Set how long LCD and buttons remain at full brightness after access Options: Delay Multiplier: Set the step size used when adjusting any delay times on the unit Delay Units: Choose how delay times are displayed ­ in either time or distance. Security: Security Code: Last used code for local lock of front panel controls System Lock: Current local lock state ­ may be changed remotely, but see page 35 for details of how this works. Operator's Manual DC1048 Integrated Audio Management Page 31 Connection of Multiple Units on an RS485 Network The USB Connection is the easiest and quickest way to connect to a single unit when uploading presets or updating firmware, and is the best connection for a "set and forget" system, where the cable can be unplugged and the system then left secure. If, however, a larger system of more than one unit is required, and real time monitoring and adjustment of these units is required on a regular basis, then the RS485 network connection on the rear panel is more useful. Additionally, other devices can share this RS485 network and can be monitored and controlled through ICORE. Connection via front panel USB and break-in to the RS485 Network Laptop or desktop PC running iCORE software monitors and controls all units. Baud rate must be set to 115k! COMMS Menu Mode: Master Connect to USB on front ID Number: 1 ­ 32 Set address for remote access RS Baud: 4800 ­ 15200k Baud rate must match on all units QUICK ACCESS COMMS GPI SYSTEM INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK x ta IC ORE S\U A B C D DC1048 1 2 3 4 5 6 7 8 USB from PC into front of first unit. . . . . . RS485 out of rear of first unit into second. . . xta 90V-240V AC 50 - 60Hz 30W GPIO PORT RS485 1-4: OUTPUT 5-8: INPUTS 9: +5V / 10: CHASSIS GND 11 - 12: ISOLA TED GND 1 2 3 4 5 6 7 8 9 10 11 12 WAR NING: THIS EQUIPMENT MUST BE EA RTHED. DO NOT REMOVECOVERS. INSTALLATION AUDIO MANAGEMENT DC1 048 Serial No: 0000001 D C MANUFACTUREDIN THE UK BY 8 7 BALANCED OUTPUTS 6 5 4 3 2 1 BALANCED INPUTS x ta A DC1048 B COMMS Menu Mode: Slave Connect to RS485 on rear panel ID Number: 2 Select next address RS Baud: 4800 ­ 15200k Baud rate must match on all units QUICK ACCESS COMMS GPI SYSTEM INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK x ta IC ORE S\U A B C D DC1048 1 2 3 4 5 6 7 8 90V-240V AC 50 - 60Hz 30W GPIO PORT RS485 1-4: OUTPUT 5-8: INPUTS 9: +5V / 10: CHASSIS GND 11 - 12: ISOLA TED GND 1 2 3 4 5 6 7 8 9 10 11 12 WAR NING: THIS EQUIPMENT MUST BE EA RTHED. DO NOT REMOVECOVERS. INSTALLATION AUDIO MANAGEMENT DC1 048 Serial No: 0000001 D C MANUFACTUREDIN THE UK BY 8 7 BALANCED OUTPUTS 6 5 4 3 BALANCED INPUTS x ta A 2 1 . . . Parallel connections from second unit into third unit. . . DC1048 x ta B COMMS Menu Mode: Slave Connect to RS485 on rear panel ID Number: 3 Select next address RS Baud: 4800 ­ 15200k Baud rate must match on all units QUICK ACCESS COMMS GPI SYSTEM INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK . . . continue up to total of 32 units and TOTAL max cable length of 1000m. IC ORE S\U x ta A B C D DC1048 1 2 3 4 5 6 7 8 COMMS Menu Mode: Slave Connect to RS485 on rear panel ID Number: 4 Select next address RS Baud: 4800 ­ 15200k Baud rate must match on all units QUICK ACCESS COMMS GPI SYSTEM INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK x ta IC ORE S\U A B C D DC1048 1 2 3 4 5 6 7 8 Page 32 DC1048 Integrated Audio Management Operator's Manual Connection directly to the RS485 Network If a connection to the first unit cannot be easily achieved with a USB cable (due to location of this unit) then a longer RS485 connection is possible via the rear panel connection using a suitable RS485 converter. We recommend the KK Systems USB-485 adapter for simple conversion to RS485. This device is powered via the USB connection and so has the ability to drive long cable runs reliably. This device is available from us, or directly from KK Systems at www. kk-systems. com. The converter comes with a 9-pin D-type fitted as standard ­ this has to be adapted to an XLR connection. To prevent voiding the warranty on the converter, we advise not cutting the 9-pin off, but rather make up an adapter ­ the pin out for this is below. 9-pin D type Pin 4 Pins 3+7 (Brown + Orange) XLR 1 2 Phoenix 1 2 Pins 8+2 (Black + Yellow) 3 3 Remember to set the first unit to SLAVE mode instead of MASTER so it accepts data on the rear Phoenix instead of the USB. Also, the baud rate setting in iCore now must match that of all connected units. See page 14 for how to change this. Operator's Manual DC1048 Integrated Audio Management Page 33 Connect to the first unit via its RS485 socket. To connect to further units, just use standard microphone cable (or similar), come out of the first unit on the Phoenix and simply parallel the three wires to the next device, and so on down the chain as shown in the previous diagram. Laptop or desktop PC running iCORE software monitors and controls all units. COMMS Menu Mode: Slave Connect to RS485 on rear panel ID Number: 1 ­ 32 Set address for remote access RS Baud: 4800 ­ 15200k Baud rate must match that at PC QUICK ACCESS COMMS GPI SYSTEM INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK x ta ICORE S\U A B C D DC1048 1 2 3 4 5 6 7 8 USB from PC through converter and into rear RS485 connection on first unit. . . . . . RS485 out of rear of first unit into second. . . x ta 90V-240V AC 50 - 60Hz 30W GPIO PORT RS485 1-4: OUTPUT 5-8: INPUTS 9: +5V / 10: CHA SSIS GND 11 - 12: ISOLATE GND D 1 2 3 4 5 6 7 8 9 10 11 12 WARNING: THIS EQUIPMEN MUST BE EAR T THED. DO NOT RE MOVE COVERS. INSTALLATION AUDIO MAN AGEMENT DC1048 Serial No: 0000001 D C MANUFACTUREDIN THE UK BY 8 7 BAL ANCED OUTPUTS 6 5 4 3 2 1 BALANCED INPUTS x ta A DC1048 B COMMS Menu Mode: Slave Connect to RS485 on rear panel ID Number: 2 Select next address RS Baud: 4800 ­ 15200k Baud rate must match that at PC QUICK ACCES S COMMS GPI SYSTEM INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK x ta ICORE S\U A B C D DC1048 1 2 3 4 5 6 7 8 90V-240V AC 50 - 60Hz 30W GPIO PORT RS485 1-4: OUTPUT 5-8: INPUTS 9: +5V / 10: CHA SSIS GND 11 - 12: ISOLATE GND D 1 2 3 4 5 6 7 8 9 10 11 12 WARNING: THIS EQUIPMEN MUST BE EAR T THED. DO NOT RE MOVE COVERS. INSTALLATION AUDIO MAN AGEMENT DC1048 Serial No: 0000001 D C MANUFACTUREDIN THE UK BY 8 7 BAL ANCED OUTPUTS 6 5 4 3 BALANCED INPUTS x ta A 2 1 B . . . Parallel connections from second unit into third unit. . . COMMS Menu Mode: Slave Connect to RS485 on rear panel ID Number: 3 Select next address RS Baud: 4800 ­ 15200k Baud rate must match that at PC QUICK ACCESS COMMS GPI SYSTEM DC1048 xta INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK . . . continue up to total of 32 units and TOTAL max cable length of 1000m. ICORE S\U x ta A B C D DC1048 1 2 3 4 5 6 7 8 COMMS Menu Mode: Slave Connect to RS485 on rear panel ID Number: 4 Select next address RS Baud: 4800 ­ 15200k Baud rate must match that at PC QUICK ACCES S COMMS GPI SYSTEM INPUTS CLIP -3 -6 -12 -24 INTEGRATED AUDIO MANAGEMENT L+4 LIM -6 -12 -24 OUTPUTS PRESETS OK x ta ICORE S\U A B C D DC1048 1 2 3 4 5 6 7 8 We strongly recommend that you use screened cable for these connections and be sure to ground one end of the screen. As the RS485 drivers used are "quarter load" devices, the maximum number of nodes that can be connected together is 128, and the maximum theoretical cable length from the first node to the last node is 1000 metres. This distance will be affected by the cable quality and to some extent the operating environment. Page 34 DC1048 Integrated Audio Management Operator's Manual Security and Locking Overview The DC1048 and ICORE both have security systems that allow for local and remote security to be implemented entirely independently. Via the front panel of the unit itself, control may be restricted or entirely prevented. Through ICORE, access to internal unit settings may be restricted though user levels with individual rights given to up to ten users, each with their own username and password. Local Front Panel Locking Pressing the Sys. [. . . ] However, the gain does increase again above this frequency to settle at 12dB down from 0dBr. This filter can be used in conjunction with the standard crossover filters to produce sharper roll-offs than would be otherwise achievable. As can be seen, number 2 is significantly steeper in roll-off than number 1, as would be expected. 1 2 3 However, number 3 is a 12dB/Octave Butterworth filter with an Elliptical Low Pass filter following it. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE XTA DC1048




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual XTA DC1048 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.