User manual WHIRLPOOL WRF535SMBW USE & CARE GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual WHIRLPOOL WRF535SMBW. We hope that this WHIRLPOOL WRF535SMBW user guide will be useful to you.


WHIRLPOOL WRF535SMBW USE & CARE GUIDE: Download the complete user guide (1539 Ko)

You may also download the following manuals related to this product:

   WHIRLPOOL WRF535SMBW ENERGY GUIDE (118 ko)
   WHIRLPOOL WRF535SMBW DIMENSION GUIDE (91 ko)
   WHIRLPOOL WRF535SMBW WARRANTY INFORMATION (93 ko)

Manual abstract: user guide WHIRLPOOL WRF535SMBWUSE & CARE GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] After that is the sanitation section, followed by service diagnosis and repair. Additional Maintenance . page 23 page 24 · CME506R, a 115 volt, dual evaporator machine · CME656R and WRF535SMBW, 230 volt, dual evaporator machines Specifications: . . . . . . . . . . . . page 2 page 3 page 4 page 5 page 6 page 7 page 8 page 9 Table Of Contents Pre-Installation . page 28 page 29 page 30 page 31 page 32 page 33 page 34 page 35 page 36 Remote Condenser Location . [. . . ] The refrigeration system is similar to that of most commercial cube ice machines. Heat is removed The AutoIQ Controller operates the ice machine by from the water and discharged out the condenser during the freeze cycle. As liquid refrigerant monitoring several input measures and switching passes thru the Thermostatic Expansion Valve, it various loads on and off. enters the bottom of the evaporators, and will form on the bottom first. When cubes need to be Water System: released (Harvest) the Hot Gas Bypass Valve is Water flows into the ice machine during the opened and Hot discharge gas flows directly from harvest cycle from thru the inlet water valve. This water valve will NOT be open the complete length warms up the evaporators and the surface of the of the harvest cycle. Ice then whenever the machine is on, and it forces water to falls into the bin. The un-frozen water falls thru the cube deflector and back into the Controller Inputs: reservoir. This is level in the reservoir falls, and at the point where the cubes are fully formed, the water level sensor measured by a thermistor located in the water pump outlet. indicates to the AutoIQ Controller that it is time to begin the Harvest cycle. This is measured During the Harvest cycle, water again enters the water reservoir, and overfills it to rinse the reservoir of accumulated minerals. If the bottom unit is in harvest and receives a signal from the top unit that it is also in Harvest, Note: Machines built after August 1996: the bottom unit will stay in harvest for its Maximum · If the machine remains in the harvest cycle Harvest Time. for longer than between 6 -9 minutes Diagnostic Lights and Manual Resets (depending upon the regular harvest cycle's length) the water pump will be switched off The controller will shut the machine off if a malfunction is sensed. · When the bin is full and the unit is in a harvest cycle, the pump will be switched off. Controllers marked 17-1 and up will restart the machine 2 times, with a 50 minute interval The AutoIQ Controller checks how long it takes to between restarts. fill the reservoir, and if it was too much time, the If a malfunction is still present after the second machine Shuts Down on Water Error. restart, the machine will then shut off and must be Note: The machine will automatically attempt to manually reset. During the restart interval, the restart after shutting down because of a lack of machine will be off and a diagnostic code water. When The inlet water valve will stay on and open for a switched off because of lack of water, the machine predetermined fraction of the time it took to fill the will always try to re-fill the reservoir every 20 reservoir. As before, During the Harvest Cycle, ice will be falling from there must be two consecutive harvest errors to the evaporators and between the bin control's trigger a machine shut-down. The AutoIQ Controller monitors the controller will still shut down and restart the ice falling and stays in the Harvest Cycle until ice machine after two consecutive harvest errors. However, if the errors repeat two more consecutive times, the controller will shut down The maximum harvest time is 10 minutes. [. . . ] If all of the refrigerant charge has not been weighed into the discharge side, it must be carefully added thru the low side. Then, with the machine running and the middle hose outlet securely fastened to the manifold or refrigerant tank (closed) open both 7. This allows any liquid refrigerant the low side port, start the ice machine. Crack open the low side manifold valve and watch the scale and sight glass. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE WHIRLPOOL WRF535SMBW




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual WHIRLPOOL WRF535SMBW will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.