User manual VOLTA 4540

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VOLTA 4540. We hope that this VOLTA 4540 user guide will be useful to you.


VOLTA 4540 : Download the complete user guide (1234 Ko)

Manual abstract: user guide VOLTA 4540

Detailed instructions for use are in the User's Guide.

[. . . ] appliance, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. If the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. If there is any doubt, have the electrical system of the house checked by a qualified electrician. ~ b) Before servicing or cleaning the ~ This appliance is intended for ~ This appliance complies with current safety requirements. [. . . ] ^ If the procedure is not stored within 4 minutes, the hood will automatically default to the "old" data. Automatic Safety Shut-Off If the ventilation system is left on, the fan will turn automatically off 10 hours after the last button was activated. ^ Press the On/Off button K to turn the fan back on again. 11 Cleaning and care , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "Important Safety Instructions". Avoid: – cleaning agents containing soda, acids or chlorides, – abrasive cleaning agents e. g. pot scourers or sponges which have been previously used with abrasive cleaning agents. ^ Turn the hood off. 13 Cleaning and care Inserting / replacing the active charcoal filters For recirculation mode an active charcoal filter must be used in addition to the grease filter. The active charcoal filter is inserted above the grease filter. ^ To insert the grease filter, make sure that the red plastic guides are at the front and facing up. It should glide onto the fixing pins. ^ Replace the filter every 6 months or when it is no longer absorbing cooking odors. ^ Dispose of the charcoal filter with the household waste. 14 Cleaning and care Changing the light bulbs , WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before changing the light bulbs, disconnect the hood from the power supply, see "Important Safety Instructions". When in use halogen bulbs become extremely hot, use caution. Do not attempt to change the bulbs until they have had sufficient time to cool. Fingerprints or body oils deposited on the bulb will decrease its life. – If there is more than one appliance beneath the hood and they have different minimum safety distances always select the greater distance. See "Important Safety Instructions" for further information. 23 Installation Installation accessories 24 Installation a 2 runners (1 x right, 1x left) to support the hood in the cabinet. b 1 spacer strip to conceal the gap between the rear of the appliance and the wall. c Installation kit for recirculation mode; contains air outlet grille, hose and hose clips (optional accessory) d Installation kit DML 400 to install a custom panel contains retractable brackets and screws (optional accessory) 8 screws 4 x 15 mm to anchor the ventilation hood in the cabinet. 8 screws M4 x 12 mm to anchor the ventilation hood at the runners. 4 screws could be used (alternatively to the plastic rivet) to fix the spacer bar. To avoid risk of hand or other injury, avoid contact with sharp edges during the assembly and installation process. , CAUTION 2 screws 4 x 30 mm to anchor the ventilation hood at rear wall. 4 plastic rivets to connect the space bar with the appliance rear wall. 25 Installation 26 Installation 1. Installing the space bar T = K cabinet depth minus G hood depth ^ The hood depth G depends on the custom panel: – a Hood installed without front panel – b Hood installed with a cabinet matching custom panel These measures are only valid for the installation if the front panel sits flush with the cabinet corpus (without the door). If the front panel should be installed recessed or flush with the cabinet door, adjust the measure T accordingly. Clip it with a knife at the predetermined breaking point of the next lower measure. ^ Screw the space bar flush with the wall under the cabinet side walls. ^ At the front edge of the spacer strip draw a vertical line on left and right side of the inside cabinet. 27 Installation 2. Do not remove the installation protector between the deflector and casing before the installation is completed. The runners are made for side walls of 5/8" (16 mm) and 3/4" (19 mm). Screw on the angled side which has the imprint of the respective cabinet wall measure. [. . . ] ^ Install the Active Charcoal Filter (see "Cleaning and care"). 33 Air extraction , WARNING Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VOLTA 4540




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VOLTA 4540 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.