User manual VAILLANT VAM 2-110 W4N INSTALLATION

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual VAILLANT VAM 2-110 W4N. We hope that this VAILLANT VAM 2-110 W4N user guide will be useful to you.


VAILLANT VAM 2-110 W4N INSTALLATION: Download the complete user guide (479 Ko)

You may also download the following manuals related to this product:

   VAILLANT VAM 2-110 W4N TECHNICAL DOSSIER (1004 ko)

Manual abstract: user guide VAILLANT VAM 2-110 W4NINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] climaVAIR VAM 2-050 W2N VAM 2-060 W2N VAM 2-085 W3N VAM 2-110 W4N DE, EN, HR, IT, TR For the fitter Installation Manual Air-conditioner - climaVAIR Split Type VAM 2-050 W2N VAM 2-060 W2N VAM 2-085 W3N VAM 2-110 W4N EN Contents Contents 1 1. 1 1. 2 2 3 4 5 5. 1 5. 2 5. 3 5. 4 5. 5 5. 6 6 7 8 8. 1 8. 2 8. 3 9 9. 1 9. 2 9. 3 9. 3. 1 9. 3. 2 9. 3. 3 9. 3. 4 9. 3. 5 9. 3. 6 10 10. 1 10. 2 10. 3 10. 4 11 11. 1 11. 2 11. 3 11. 4 11. 5 Your Safety . 8 General precautions to be taken into account before starting the installation . . 12 Correct installation of the refrigerant pipe work . 12 Installation of the Indoor Unit Body . 22 2 Split Type Installation Manual Your Safety 1 Extreme operating conditions 2 Identification of the Unit 3 1 1. 1 Your Safety Symbols used Danger! [. . . ] · Tilt the lower part of the indoor unit forwards and insert an auxiliary tool (e. g. a piece of wood) between the mounting plate and the unit (see Figure 9. 8) to allow access to the unit connections. 025 /035 Installation plate 120mm or more to wall 790 mm Right refrigerant pipe hole Ø 65 Fig. 9. 1 Dimensions of the hole for the piping. · Case B: Running the pipework out of either side or the bottom of the unit. In this case holes do not have to made in the wall since the indoor unit body has knock outs which can be opened to allow the pipes to exit the unit: choose the most convenient one for the desired outlet position (see Figure 9. 7). · Carefully break the knock out in the casing using pliers. Fig. Legend 1 Exit for right piping 2 Exit for indoor piping 3 Securing with adhesive tape 4 Exit for left piping Fig. 9. 8 Assembling the indoor unit. · Connect the coolant pipes from the outdoor unit and the condensed water hose to the installation drain. · Insulate the coolant piping and joints correctly and separately. To do so, cover any possible cuts with masking tape or insulate any bare coolant piping with the corresponding insulation material suitable for air conditioning installations (for connection of the electrical wiring see section 11). 12 Split Type Installation Manual Installation of the indoor unit 9 Installation of the outdoor unit 10 10 Installation of the Outdoor Unit 10. 1 Selecting the Assembly Location Warning!Outdoor units must be placed in accessible areas for subsequent maintenance and repair operations. Vaillant will not be responsible for any costs derived from incorrect positioning that prevents easy access. Install the unit away from inflammable gasses or liquids or easily combustible substances and free from thick dust formation. Ensure that the ground is smooth and level and can withstand the weight of the outdoor unit. - The outdoor unit can only be mounted outdoors, never inside a building. - Do not install the unit in such a way that the air discharge affects the air inlets of premises nearby. - Ensure that there is sufficient space to observe the minimum distances (see Figure 8. 1). - Comply with local regulations: there are considerable differences dependant on the area. - Leave enough space to fit the condensed water drainage pipe (see section 10. 4). Fig. Legend 1 Heat-resistant material 2 Drain pipe 3 Coolant pipe 4 Piping support plate 5 Indoor/outdoor electric cable · For pipework exiting from the right hand side and bottom of the unit extend the pipework through the relevant knock out before hanging unit (see section 9. 3. 6). · For pipework exiting from the left of the unit, make the connections at the rear of the unit first before hanging the unit (see section 9. 3. 6). The flare connections should be, where possible, accessible to allow leak test and future access. 9. 3. 6 Installation of the Indoor Unit Body · Check that the installation has been carried out correctly and that there are no leaks (see section 12. 1). [. . . ] · Do not continue to the next step until the pressure test has been successfully completed. 12. 2 Evacuating the installation Legend 1 Suction valve (gas) 2 Return valve (liquid) 3 Service manifold 4 Non-return joint 5 Gauge lines 6 Vacuum pump suitable for refrigeration systems · Connect a service manifold to the three-way valve on the gas line of the outdoor unit. · Connect a vacuum pump to the charging connection of the service manifold. · Turn the vacuum pump on and open the service manifold shut off valve to open the system to the vacuum pump · Ensure that all other valves are closed. · Leave the vacuum pump functioning for approximately 15 minutes (depending on the size of the installation) to carry out the vacuum. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE VAILLANT VAM 2-110 W4N




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual VAILLANT VAM 2-110 W4N will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.