User manual TRIMBLE TERRASYNC 2.21 RELEASE NOTES REV B

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TRIMBLE TERRASYNC 2.21. We hope that this TRIMBLE TERRASYNC 2.21 user guide will be useful to you.


TRIMBLE TERRASYNC 2.21 RELEASE NOTES REV B: Download the complete user guide (606 Ko)

Manual abstract: user guide TRIMBLE TERRASYNC 2.21RELEASE NOTES REV B

Detailed instructions for use are in the User's Guide.

[. . . ] TerraSyncTM Release Notes Version 2. 21 October 2002 Revision B Trimble Navigation Limited Mapping & GIS Division 645 North Mary Avenue Post Office Box 3642 Sunnyvale, CA 94085 U. S. A. Phone: +1-408-481-8940 1-800-545-7762 Fax: +1-408-481-7744 www. trimble. com Legal Information Revision Notice This is the October 2002 release (Revision B) of the TerraSync Release Notes. It applies to version 2. 21 of the TerraSyncTM software. Copyright © 2000­2002 Trimble Navigation Limited. For STL support, the TerraSync software uses the Moscow Center for SPARC Technology adaptation of the SGI Standard Template Library. © 1994 Hewlett-Packard Company, © 1996, 97 Silicon Graphics Computer Systems, Inc. , © 1997 Moscow Center for SPARC Technology. [. . . ] You must ensure that 10 MB is free before you begin installation. If memory space on the device is insufficient, this message appears during installation: Click Cancel, remove any unwanted programs or data files from your CE device, and/or increase storage memory (see Changing Memory Allocation on a CE Device). Then start the installation again. More. . . TerraSync Release Notes Installation on a CE Device 27 If memory space in the secondary internal storage location is insufficient, the installation may appear to complete successfully, but error messages may appear when you try to run the TerraSync software. If this happens, make more space available in the secondary storage location, then install the software again. If the problem persists, perform a full hard reset of the CE device, then reinstall the TerraSync software. For information on performing a full hard reset, visit the Trimble website at www. trimble. com/support. html and click TerraSync. NOTE Trimble recommends that you uninstall any previously installed versions of the TerraSync software and transfer any TerraSync data files to your office computer before installing the latest version. You can use any of the following methods: · · serial cable infrared · · cradle modem · · USB network card For information on connecting your CE device to another computer, refer to the documentation for your CE device. If an ActiveSync partnership for these two computers exists, ActiveSync starts and the office computer connects to the CE device automatically. More. . . TerraSync Release Notes Installation on a CE Device 28 NOTE ActiveSync cannot connect to a CE device that is communicating with a GPS receiver on the same port. If you are upgrading or reinstalling the TerraSync software, make sure you disconnect from GPS and exit the software. If there is no partnership, or the computers do not connect, you may need to reinstall ActiveSync on your office computer. When the two computers are connected, the Microsoft ActiveSync window appears and displays the message Connected: More. . . TerraSync Release Notes Installation on a CE Device 29 TIP If ActiveSync is installed, but the two computers do not connect, check that the CE device is set up to establish a PC connection. For information on how to do this, refer to the documentation for your CE device. You should also ensure that the CE device is configured to connect at the maximum baud rate available. TIP 3. Do one of the following: · Visit the Trimble website at www. trimble. com/support. html. Click the appropriate link in the table to download the TerraSync 2. 21 web update for your device type and processor. Run the TerraSync Updater utility from the version 2. 20 TerraSync Software & Operation Guide CD and follow the instructions on the screen to download the appropriate TerraSync 2. 21 web update for your device and processor. · More. . . TerraSync Release Notes Installation on a CE Device 30 5. The TerraSync installation wizard appears: More. . . TerraSync Release Notes Installation on a CE Device 31 6. Follow the instructions on the screen to install the TerraSync software. You will need to enter your TerraSync version 2. 20 serial number and authorization key (displayed on the CD case). When the message Install "Trimble TerraSync" using the default application install directory?appears, do one of the following: · Click Yes to install the software to the default location. Use this option if you are installing onto a CE device that has no secondary storage, or only has removable secondary storage such as a CompactFlash card. Click No to install the software to an internal secondary storage location. [. . . ] If you are unsure whether a powered connection will cause damage, refer to the user manual for your field computer or consult the manufacturer before using P/N 30236. TIP The GPS Pathfinder Pocket receiver does not output power and can be safely connected directly to your field computer. A field computer uses more power when a GPS receiver is connected to its CompactFlash serial port. This type of connection will discharge the field computer's battery more quickly. NOTE If you have a Compaq iPAQ, and you are using a CompactFlash serial adapter to provide a serial connection to the GPS receiver, configure the receiver to connect to the serial port COM4. TerraSync Release Notes Cabling 46 Pro XR Cabling To use a field computer with a standard serial port with the GPS Pathfinder Pro XR receiver, connect the system as shown in Figure 1. 1 8 2 5 3 4 4 7 Figure 1 1 P/N 29653-00 9 2 P/N 22628 3 P/N 38073-11 or P/N 46090-11 12-channel Pro XR receiver 4 P/N 17466 Camcorder batteries 5 P/N 30232-00 NMEA/RTCM cable 6 P/N 30231-00 Data/power cable 7 P/N 24333 Dual battery cable 8 P/N 45052 Field computer data cable 9 Field computer with standard serial port Integrated GPS/ beacon antenna Antenna cable 6 Connecting a Pro XR receiver to a field computer with a standard serial port More. . . TerraSync Release Notes Cabling 47 To use a field computer with a customized serial port with the GPS Pathfinder Pro XR receiver, connect the system as shown in Figure 2. 10 1 9 2 5 3 4 4 7 Figure 2 1 P/N 29653-00 8 6 2 P/N 22628 3 P/N 38073-11 or P/N 46090-11 12-channel Pro XR receiver 4 P/N 17466 Camcorder batteries 5 P/N 30232-00 NMEA/RTCM cable 6 P/N 30231-00 Data/power cable 7 P/N 24333 Dual battery cable 8 P/N 43197 Null modem adapter 9 Custom data cable (supplied with field computer) 10 Field computer with custom serial port Integrated GPS/ beacon antenna Antenna cable Connecting a Pro XR receiver to a field computer with a custom serial port TerraSync Release Notes Cabling 48 Pro XRS Cabling To use a field computer with a standard serial port with the GPS Pathfinder Pro XRS receiver, connect the system as shown in Figure 3. 1 P/N 33580-50 1 8 2 5 3 4 4 7 Figure 3 TerraSync Release Notes 2 3 4 5 6 7 8 9 9 Combined L1 GPS/ MSK beacon/ satellite differential antenna P/N 22628 Antenna cable P/N 33302-51 12-channel Pro XRS receiver P/N 17466 Camcorder batteries P/N 30232-00 NMEA/RTCM cable P/N 30231-00 Data/power cable P/N 24333 Dual battery cable P/N 45052 Field computer data cable Field computer with standard serial port 6 Connecting a Pro XRS receiver to a field computer with a standard serial port More. . . Cabling 49 To use a field computer with a customized serial port with the GPS Pathfinder Pro XRS receiver, connect the system as shown in Figure 4. 10 1 9 2 5 3 4 4 7 Figure 4 8 6 Combined L1 GPS/ MSK beacon/ satellite differential antenna 2 P/N 22628 Antenna cable 3 P/N 33302-51 12-channel Pro XRS receiver 4 P/N 17466 Camcorder batteries 5 P/N 30232-00 NMEA/RTCM cable 6 P/N 30231-00 Data/power cable 7 P/N 24333 Dual battery cable 8 P/N 43197 Null modem adapter 9 Custom data cable (supplied with field computer) 10 Field computer with custom serial port 1 P/N 33580-50 Connecting a Pro XRS receiver to a field computer with a custom serial port TerraSync Release Notes Cabling 50 Pro XL Cabling To use a field computer with a standard serial port with the GPS Pathfinder Pro XL receiver, connect the system as shown in Figure 5. 1 6 4 7 1 P/N 16741-00 2 P/N 17515-01 3 P/N 22850-00 P/N 22850-10 4 P/N 24333 5 P/N 17466 6 P/N 17664-31 5 2 3 8 Compact Dome antenna Antenna cable 12-channel Pro XL receiver or 8-channel Pro XL receiver Dual battery cable Camcorder batteries Field computer/GPS receiver multiport cable 7 P/N 45052 Field computer data cable 8 Field computer with standard serial port Figure 5 NOTE Connecting a Pro XL receiver to a field computer with a standard serial port The Pro XL is an obsolete receiver. More. . . TerraSync Release Notes Cabling 51 To use a field computer with a customized serial port with the GPS Pathfinder Pro XL receiver, connect the system as shown in Figure 6. 1 6 4 9 7 1 P/N 16741-00 2 P/N 17515-01 3 P/N 22850-00 P/N 22850-10 4 P/N 24333 5 P/N 17466 6 P/N 17664-31 5 2 Figure 6 NOTE 3 8 Compact Dome antenna Antenna cable 12-channel Pro XL receiver or 8-channel Pro XL receiver Dual battery cable Camcorder batteries Field computer/GPS receiver multiport cable 7 P/N 43197 Null modem adapter 8 Custom data cable (supplied with field computer) 9 Field computer with custom serial port Connecting a Pro XL receiver to a field computer with a custom serial port The Pro XL is an obsolete receiver. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TRIMBLE TERRASYNC 2.21




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TRIMBLE TERRASYNC 2.21 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.