Manual abstract: user guide TOSHIBA RAS-M18GAV-ESERVICE MANUAL
Detailed instructions for use are in the User's Guide.
[. . . ] A05-009
SERVICE MANUAL
SPLIT TYPE
<Heat Pump Type>
Indoor Unit
<Cooling OnlyType>
Indoor Unit
RAS-B10GKVP-E RAS-M10GKCVP-E RAS-B13GKVP-E RAS-M13GKCVP-E RAS-B16GKVP-E RAS-M16GKCVP-E
Outdoor Unit Outdoor Unit
RAS-M14GAV-E RAS-M18GAV-E
RAS-M14GACV-E RAS-M18GACV-E
R410A
PRINTED IN JAPAN, Nov. , 2005 ToMo
CONTENTS
1. SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT R410A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Piping and Drain Hose Installation Piping and drain hose forming
· Since condensation results in machine trouble, make sure to insulate both the connecting pipes separately. (Use polyethylene foam as insulating material. )
Rear right
Cord clamp
Left
Terminal block
Bottom right Right
Earth wire Connecting cable
Fig. Die-cutting front panel slit Cut out the slit on the left or right side of the front panel for the left or right connection and the slit on the bottom left or side of thefront panel for the bottom left or right connection with a pair of nippers. Changing drain hose For left connection, left-bottom connection and rear-left connection's piping, it is necessary to relocate the drain hose and drain cap.
Fig. 10-3-7
How to remove the drain cap
Clip drain cap with needle-nose pliers, and pull out.
Connecting cable
About 15 cm
Fig. 10-3-11
How to remove the drain hose
The drain hose is secured in place by a screw. Remove the screw securing the drain hose, then pull out the drain hose.
10 mm 50 mm
Fig. 10-3-12
63
Die-cutting Front panel slit
Bottom left
Drain hose
Changing drain hose
Rear left
Piping preparation
Screw
Screw
How to attach the drain cap
1. Insert hexagonal wrench (4 mm).
In case of bottom right or bottom left piping
· After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.
Slit
4 mm
Fig. Bend the connecting pipes so that they are positioned within 43 mm above the wall surface. If the connecting pipes are positioned more than 43 mm above the wall surface, the indoor unit may be unstable. When bending the connecting pipe, make sure to use a spring bender to avoid crushing the pipe.
No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. If applied, deterioration and drain leakage of the drain plug may occur.
Insert a hexagon wrench (Ø4mm)
Refer to the table below for the bending radius of each connection pipe.
Outer diameter 6. 35 mm Bending radius 30 mm 40 mm 50 mm
Fig. 10-3-14
How to attach the drain hose
Always use the original screw that secured the drain hose to the unit. Insert the drain hose firmly until the connector contacts with the insulation, then secure it in place using the original screw.
9. 52 mm 12. 7 mm
To connect the pipe after installation of the unit (figure)
(To the front flare)
220 mm
Gas side
CAUTION
Securely insert the drain hose and drain cap; otherwise, water may leak.
170 mm
Liquid side
R30 or less (Ø6. 35), R40 or less (Ø9. 7) Use polishing (polyethylene core or the like for bending pipe).
43 mm
In case of right or left piping
· After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool.
Outward form of indoor unit
Use a screwdriver handle, etc.
Fig. 10-3-15
NOTE : If the pipe is incorrectly bent, the indoor unit may be unstable on the wall. After passing the connecting pipe through the pipe hole, connect the connecting pipe to the auxiliary pipes and wrap the facing tape around them.
64
CAUTION
· Bind the auxiliary pipes (two) and connecting cable with facing tape tightly. In case of leftward piping and rear-leftward piping, bind the auxiliary pipes (two) only with facing tape.
Indoor unit Auxiliary pipes Installation plate Connecting cable
10-3-7. Run the drain hose at a downward sloped angle.
NOTE : · Hole should be made at a slight downward slant on the outdoor side.
Do not rise the drain hose. Do not form the drain hose into the waved shape.
50 mm or more
Fig. 10-3-18 · Carefully arrange the pipes so that none of the pipes stick out of the rear plate of the indoor unit. [. . . ] (within 20cm from the outdoor unit base plate) * Be careful that the cord heater does not hit the fan. Drill a hole on the side cabinet (R) for fixing the thermostat fixing plate.
2-2
PVC tube Ø9. 1 P-shape clamp
Heating part
Enlarged marked part
Added hole 2-5 5 46 7
Ø5 hole at two positions When drilling a hole on the side cabinet (R), be sure not to damage the cabinet.
2-3
Side cabinet (R)
Appendix-6
Appendix
No. Photo / Explanatory diagram
Side cabinet (L)
Procedure Rework the side cabinet (L) to remove part of it. The area to be removed is indicated by the shaded lines in the left figure. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TOSHIBA RAS-M18GAV-E
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TOSHIBA RAS-M18GAV-E will begin.