User manual TEKTRONIX TDS3052C DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX TDS3052C. We hope that this TEKTRONIX TDS3052C user guide will be useful to you.


TEKTRONIX TDS3052C DATASHEET: Download the complete user guide (979 Ko)

Manual abstract: user guide TEKTRONIX TDS3052CDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Fast waveform capture rates on a continuous basis save time by quickly revealing the nature of faults so advanced triggers can be applied to isolate them. Real-time intensity grading highlights the details about the history of a signal's activity, making it easier to understand the characteristics of the waveforms you've captured. Unlike other comparable oscilloscopes, the history remains even after the acquisition is stopped. [. . . ] And when you need to move your oscilloscope to another lab, its portable 7 lb. If your work demands even more mobility, then the optional battery pack will give you up to three hours of operation without line power. TDS3BATC provides you with up to three hours of portable battery operation. Characteristics TDS3000C Series Electrical Characteristics Characteristic TDS3012C TDS3014C TDS3032C TDS3034C TDS3052C TDS3054C Bandwidth Calculated Rise Time (typical) Input Channels External Trigger Input Sample Rate on each channel Record Length Vertical Resolution Vertical Sensitivity, 1 M Vertical Sensitivity, 50 Input Coupling Input Impedance DC Gain Accuracy Maximum Input Voltage, 1 M Maximum Input Voltage, 50 Position Range Bandwidth Limit Time Base Range Time Base Accuracy Input/Output Interfaces 100 MHz 3. 5 ns 2 1. 25 GS/s 100 MHz 3. 5 ns 4 1. 25 GS/s 300 MHz 1. 2 ns 2 300 MHz 1. 2 ns 500 MHz 0. 7 ns 2 5 GS/s 500 MHz 0. 7 ns 4 5 GS/s 4 Included on all models 2. 5 GS/s 2. 5 GS/s 10 kpoints 9 bits 1 mV/div to 10 V/div 1 mV/div to 1 V/div AC, DC, GND 1 M in parallel with 13 pF or 50 ±2% 150 VRMS with peaks at 400 V 5 VRMS with peaks at 30 V ±5 div 20 MHz, 150 MHz 20 MHz, 150 MHz 2 ns to 10 s 2 ns to 10 s ±20 ppm over any 1 ms time interval 20 MHz 4 ns to 10 s 20 MHz 4 ns to 10 s 20 MHz, 150 MHz 1 ns to 10 s 20 MHz, 150 MHz 1 ns to 10 s Ethernet Port USB Port GPIB Port RS-232-C Port VGA Video Port External Trigger Input RJ-45 connector, supports 10Base-T LAN Front-panel USB 2. 0 host port Supports USB flash drive Full talk/listen modes, setting and measurements (Optional with TDS3GV Communications Module) DB-9 male connector, full talk/listen modes; control of all modes, settings and measurements Baud rates up to 38, 400 (Optional with TDS3GV Communications Module) DB-15 female connector, monitor output for direct display on large VGA-equipped monitors (Optional with TDS3GV Communications Module) BNC connector, input impedance >1 M in parallel with 17 pF; max input voltage is 150 VRMS 4 www. tektronix. com Digital Phosphor Oscilloscopes -- TDS3000C Series Acquisition Modes Mode Description Waveform Measurements Characteristic Description DPO Peak Detect WaveAlert® Sample Average Envelope Single Sequence Captures and displays complex waveforms, random events and subtle patterns in actual signal behavior. DPOs provide 3 dimensions of signal information in real time: Amplitude, time, and the distribution of amplitude over time High-frequency and random glitch capture. Captures glitches as narrow as 1 ns (typical) using acquisition hardware at all time base settings Monitors the incoming signals on all channels and alerts the user to any waveform that deviates from the normal waveform being acquired Sample data only Waveform averaged, selectable from 2 to 512 Min-max values acquired over one or more acquisitions Use the Single Sequence button to capture a single triggered acquisition sequence at a time Amplitude, Time Cursors Automatic Measurements Display any four measurements from any combination of waveforms. Measurements include Period, Frequency, +Width, -Width, Rise time, Fall time, +Duty cycle, -Duty cycle, +Overshoot, High, Low, Max, Min, Peak-to-peak, Amplitude, Mean, Cycle mean, RMS, Cycle RMS, Burst width, Delay, Phase, Area*1, Cycle Area*1 Measurement Statistics Mean, Min, Max, Standard deviation. Requires TDS3AAM application module Thresholds User-definable thresholds for automatic measurements; settable in percent or voltage Gating Isolate a specific occurrence within an acquisition to take measurements, using either the screen or cursors *1 Requires TDS3AAM application module. Trigger System Characteristic Description Waveform Math Characteristic Description Main Trigger Modes Auto (supports Roll Mode for 40 ms/div and slower), Normal, Single Sequence B Trigger Trigger after time or events Trigger After Time Range 13. 2 ns to 50 s 1 to 9, 999, 999 events Trigger After Events Range Arithmetic FFT Advanced Math*1 Trigger Types Trigger Description Add, subtract, multiply, and divide waveforms Spectral magnitude. Set FFT vertical scale to Linear RMS or dBV RMS, and FFT window to Rectangular, Hamming, Hanning, or Blackman-Harris Integrate, Differentiate, Define extensive algebraic expressions including analog waveforms, math functions, scalars, up to two user-adjustable variables and results of parametric measurements. For example: (Intg (Ch1-Mean(Ch1)) × 1. 414 × VAR1) Note: Requires TDS3AAM application module. Edge Video Extended Video Pulse Width (or Glitch) Runt Slew Rate Pattern State Comm Alternate Conventional level-driven trigger. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject Trigger on all lines or individual lines, odd/even or all fields on NTSC, PAL, SECAM Trigger on specific lines in broadcast and non-broadcast (custom) standards and on analog HDTV formats (1080i, 1080p, 720p, 480p). Requires TDS3VID or TDS3SDI application module Trigger on a pulse width <, >, =, to a selectable time limit ranging from 39. 6 ns to 50 s Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Trigger on pulse edge rates that are either faster or slower than a set rate. Edges can be rising, falling, or either Specifies AND, OR, NAND, NOR when true or false for a specific time Any logic state. Logic triggers can be used on combinations of 2 inputs (not 4) Provides isolated pulse triggering required to perform DS1/DS3 telecommunications mask testing per ANSI T1. 102 standard. Requires TDS3TMT application module Sequentially uses each active channel as a trigger source *1 Requires TDS3AAM application module. Waveform Processing Characteristic Description Autoset Deskew Single-button, automatic setup of all channels for vertical, horizontal and trigger systems, with undo autoset Channel-to-channel deskew ±10 ns may be manually entered for better timing measurements and more accurate math waveforms Display Characteristics Characteristic Description Display Type Display Resolution Interpolation Waveform styles Graticules Format 6. 5 in. (165. 1 mm) liquid-crystal TFT color display 640 horizontal × 480 vertical pixels (VGA) Sin(x)/x Dots, vectors, variable persistence, infinite persistence Full, grid, crosshair, and frame. A99 North America Universal Euro United Kingdom Australia Switzerland Japan China India No power cord Language Options Option Description Opt. L99 English French Italian German Spanish Japanese Portuguese Simplified Chinese Traditional Chinese Korean Russian No manual 6 www. tektronix. com Digital Phosphor Oscilloscopes -- TDS3000C Series Recommended Accessories Accessory Description Recommended Probes Probe Description TDS3GV TDS3AAM TDS3LIM TDS3TMT TDS3VID TDS3SDI TDS3BATC TDS3CHG AC3000 HCTEK4321 RM3000 SIGEXPTE Service Manual TNGTDS01 GPIB, VGA, RS-232 interface Advanced Analysis Module. [. . . ] C5) Repair Service - 5 year Provides a single calibration event or coverage for the designated calibration interval, whichever comes first Repair service coverage 1 year post warranty Repair service coverage 2 years post warranty Repair service coverage 5 years (includes product warranty period); 5-year period starts at time of customer instrument purchase Available after purchase *2 Vectorscope does not support composite video. Product(s) are manufactured in ISO registered facilities. Product(s) complies with IEEE Standard 488. 1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. www. tektronix. com 7 Data Sheet Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 00800 2255 4835* Brazil +55 (11) 3759 7600 Canada 1 800 833 9200 Central East Europe, Ukraine, and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong 400 820 5835 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean (52) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098 People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia & CIS +7 (495) 7484900 South Africa +41 52 675 3777 Spain 00800 2255 4835* Sweden 00800 2255 4835* Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 25 May 2010 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX TDS3052C




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX TDS3052C will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.