User manual TEKTRONIX MSO70000 DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual TEKTRONIX MSO70000. We hope that this TEKTRONIX MSO70000 user guide will be useful to you.


TEKTRONIX MSO70000 DATASHEET: Download the complete user guide (6799 Ko)

Manual abstract: user guide TEKTRONIX MSO70000DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Digital and Mixed Signal Oscilloscopes DPO/DSA/MSO70000 Series Data Sheet Pinpoint® Triggering ­ Minimize time spent trying to acquire problem signals for efficient troubleshooting and shortened debug time 6. 25 Gb/s Real-time Serial Trigger ­ Assures triggering on the first instance of a specified NRZ or 8b/10b pattern to allow isolation of pattern-dependent effects Search & Mark ­ Provides waveform pattern matching and software triggers for signals of interest P7500 TriModeTM Probing System ­ Perfectly matched signal connectivity from 4 GHz to 20 GHz Application Support for High-speed Serial Industry Standards, RF, Power Supplies, and Memory ­ Enables standard-specific certification, measurement automation, and ease of use Features & Benefits On All Four Channels Simultaneously 20, 16, 12. 5, 8, 6, and 4 GHz Bandwidth Models Up to 50 GS/s on Real-time Sample Rate Up to 250 Megasample Record Length with MultiView ZoomTM Feature for Quick Navigation Fastest Waveform Capture Rate with >300, 000 wfms/s Maximum per Channel Uncompromised Bandwidth ­ Up to 20 GHz on all 4 channels enables measurement on the latest high-speed serial standards Superior Signal Integrity and Excellent Signal-to-Noise Ratio ­ Observe the truest representation of your waveform Industry-leading Sample Rate and Timing Resolution 100 GS/s on 2 Channels (20, 16, and 12. 5 GHz models) 16 Logic Channels with 80 ps Timing Resolution for Debug of Digital and Analog Signals (MSO70000 Series only) P6780 and P6717 High-performance 17-channel Logic Probes with Bandwidths up to 2. 5 GHz for Connections to Today's Fast Digital Signals (MSO70000 Series only) Applications Design Verification including Signal Integrity, Jitter, and Timing Analysis Design Characterization for High-speed, Sophisticated Designs Certification Testing of Serial Data Streams for Industry Standards Memory Bus Analysis and Debug Prototype Turn-on and Power Supply Verification Research and Investigation of Transient Phenomena Production Testing of Complex Systems Spectral Analysis of Transient or Wide-bandwidth RF Signals Data Sheet Unmatched Acquisition and Signal-to-Noise Performance The superior signal integrity and excellent signal-to-noise ratio of the DPO/DSA/MSO70000 Series ensures confidence in your measurement results. High bandwidth, up to 20 GHz, matched across 4 channels Bandwidth enhancement eliminates imperfections in frequency response all the way to the probe tip. The user-selectable filter for each channel provides magnitude and phase correction for more accurate representation of extremely fast signals. In addition, only Tektronix allows the user to disable the bandwidth enhancement for applications needing the highest measurement throughput Simultaneous high sample rate on all channels captures more signal details (transients, imperfections, fast edges) 100 GS/s on 2 channels and 50 GS/s on all analog channels for the 12. 5, 16, and 20 GHz models 25 GS/s on all analog channels for the 4, 6, and 8 GHz models 12. 5 GS/s on all logic channels in the MSO70000 Series Lowest jitter noise floor and highest vertical accuracy provide additional margin in your measurements Long record length provides high resolution and extended-duration waveform capture Standard 10 MS per channel on the DPO70000 and MSO70000 Series and 31 MS on the DSA70000 Series Optional up to 125 MS on all four channels for the 4, 6, and 8 GHz models Optional up to 250 MS on all four channels for the 12. 5, 16, and 20 GHz models On the MSO70000 Series, the record length of logic channels match the analog record lengths for uncompromised analog and digital acquisition MultiView Zoom helps you manage long records, compare and analyze multiple waveform segments With high signal-to-noise ratio and low internal noise floor, the DPO/DSA/MSO70000 Series enable you to perform precise characterization measurements. When debugging a DUT, a low noise floor and maximum signal fidelity of the measurement instrument allows you to find the smallest anomalies that might affect the DUT's performance. [. . . ] With 80 ps timing resolution and channel-to-channel skews of as little as 160 ps, the integrated logic channels allow you to view and measure time-correlated digital and analog data in the same display window. iCapture (MSO70000 Series only) When an anomaly is seen on digital lines, iCapture delivers new insight into the analog behavior of the digital signals. With iCapture, you can route any 4 of the 16 logic channels to the MSO70000 Series' analog acquisition system so that these signals can be viewed in finer detail. iCapture's unique multiplexer circuitry provides simultaneous digital and analog views of signals without having to move the logic probe or double probe the circuit. Integrated Logic Channels ­ Provide time-correlated analog and digital visibility for system debugging. Logic Pattern Triggering Logic pattern triggering allows logic qualification that controls when to look for the faults and ignore events that do not occur during the desired state. On the MSO70000 Series, up to 20-bit wide logic pattern triggering enhances the Pinpoint trigger capabilities by helping you isolate the specific system state and analog events that are causing system failure. 12 www. tektronix. com Digital and Mixed Signal Oscilloscopes -- DPO/DSA/MSO70000 Series FastFrame When the key events you are interested in are widely spaced in time, such as bursts of activity on a bus, FastFrame segmented memory feature on the DPO/DSA/MSO70000 Series enables you to capture the events of interest while conserving acquisition memory. Using multiple trigger events, FastFrame captures and stores short bursts of signals and saves them as frames for later viewing and analysis. On the MSO70000 Series, FastFrame and bus or logic triggering enable you to capture your fastest, bursty signals on the analog channels at the highest sample rate while the logic channel trigger recognizes the bus cycle of interest. Capturing thousands of frames is possible, so long-term trends and changes in the bursting signal can be analyzed. Advanced Search and Mark Probing ­ Analog And Digital Often the biggest challenge in debugging a system is getting access to the required signals. Tektronix offers a wide array of probing solutions, including the P7500 TriMode probing system with bandwidths that are perfectly matched to the DPO/DSA/MSO70000 Series. The P7500 TriMode probes allow you to switch among differential, single ended, and common-mode measurements without moving the probe from its connection points. The P7500 Series offers probes with performance from 4 GHz to 20 GHz and offers several low-cost solder tips with quick connection features that allow moving the probe to various solder points fast and easy. On the MSO70000 Series, the P6780 and P6717 logic probes provide connectivity to low-speed and high-speed digital signals with low loading, small size, and a range of accessories for soldering and browsing. The low-cost solder tips available for the P7500 TriMode probes allow quick connection so moving the probe to various solder points is fast and easy. Advanced Search and Mark ­ Highlights important events, skips unimportant ones, and navigates between events of interest effortlessly. Isolating the key event causing your system failure can often be a tedious task. With the Advanced Event Search and Mark feature examining data and highlighting important events, skipping the unimportant ones, and enhancing the comprehension of event relationships is made easy. With ASM, you'll be able to navigate between the events of interest effortlessly and uncover that rare event you have been trying to find. Embedded Serial Bus (I2C, SPI) Decoding and Triggering (MSO70000 Series only) The MSO70000 Series instruments provide I2C and SPI serial bus decoding and bus triggering that enable you to monitor or debug subsystems and components, such as frequency synthesizers, D/A converters, and Flash Memory that are controlled or monitored using I2C or SPI serial buses. While monitoring or debugging these serial buses alone is relatively easy, decoding events on the serial bus can also enable more complex system-level debugging. When you experience an issue with a higher-speed serial interface, the clue to what is going wrong may be found by using the serial bus decode feature to observe the data on your I2C or SPI interface. Solder tip accessories designed for the P6780 differential logic probes provide access to signals on tightly spaced vias and fine-pitched components. www. tektronix. com 13 Data Sheet Production Testing In addition to assisting engineers with design tasks, the DPO/DSA/MSO70000 Series can provide test engineers with the ability to test analog and digital signals with a wide range of clock speeds and data rates. Rackmount options are available for mounting the DPO/DSA/MSO70000 Series into an EIA standard 19 inch (487 mm) rack. An IEEE 488. 2 standard GPIB interface is standard on all models. Research With industry-leading acquisition speed and signal-to-noise ratio performance, the DPO/DSA/MSO70000 Series can provide researchers with tools that allow them to capture, display, and analyze high-speed and transient signals with unmatched precision. OpenChoice® Analysis Tools The OpenChoice Software allows you to customize your test and measurement system with familiar analysis tools. The analysis and networking features of the OpenChoice software add more flexibility to Tektronix DPO/DSA/MSO70000 Series oscilloscopes: Using the fast embedded bus, waveform data can be moved directly from acquisition to analysis applications on the Windows desktop at much faster speeds than conventional GPIB transfers. Implementation by Tektronix of industry-standard protocols, such as TekVISATM interface and ActiveX controls, are included for using and enhancing Windows applications for data analysis and documentation. [. . . ] Check www. tek. com/products/oscilloscopes/floatinglicenses for additional information about floating license options. X X X DPOFL-ASM Advanced Event Search and Mark X X X DPOFL-CP2 ANSI/ITU Telecom Pulse Compliance Test Software X X X DPOFL-D-PHY*9 MIPI® D-PHY Transmitter Debug, Characterization, and Compliance Test Solution X X X DDR Memory Bus Analysis DPOFL-DDRA*9 X X DPOFL-DJA Standard Jitter and Eye Analysis Tools ­ Advanced (DPOJET) X X DPOFL-DSA Digital Serial Analysis Bundle X X X DPOFL-DSPT*11, 12 DisplayPort Transmitter Compliance Test Software X X X DPOFL-DVI DVI Compliance Testing X X X DPOFL-ERRDT*13 Frame and Bit Error Rate Detector for High-speed Serial Standards X X X DPOFL-ET3*4 Ethernet Compliance Testing X X X FB-DIMM Memory Bus Analysis DPOFL-FBD*7 X X X DPOFL-HT3 HDMI Compliance Testing X X X DPOFL-HT3DS HDMI Direct Synthesis for HDMI 1. 4 X X X DPOFL-IBA*7 Infiniband Compliance Module X X X DPOFL-J2 Disk Drive Measurements Software X X X Jitter and Timing Measurements ­ JIT3 Advanced DPOFL-JA3 X X X DPOFL-JE3 TDSJIT3 Essentials X X X DPOFL-LT Waveform Limit Testing X X DPOFL-MTH Standard Mask Testing, includes Hardware Clock Recovery X X X DPOFL-PCE*9 PCI Express® Measurements X X DPOFL-PTD Standard Protocol Trigger and Decode for 8b/10b X X X Power Measurement and Analysis DPOFL-PWR*6 X X X DPOFL-RTE Real-time Eye ­ Serial Data Compliance and Analysis X X X DPOFL-SLA Serial Data Link Analysis ­ Advanced (includes Equalization) X X X DPOFL-SLE Serial Data Link Analysis ­ Essentials (no Equalization) X X X DPOFL-SST*7 SAS and Serial ATA Compliance Module X X DPOFL-ST6G Standard 8b/10b Serial Protocol Trigger and Decode up to 6. 25 Gb/s X DPOFL-STU Upgrade from 3. 125 Gb/s to 6. 25 Gb/s 8b/10b Serial Protocol Trigger and Decode X X X DPOFL-SVT*10 Settling Time Measurements ­ Frequency and Phase X X X DPOFL-USB*5 USB 2. 0 Compliance Testing X X X DPOFL-USB3*9, 11 USB 3. 0 Essentials X X X Ultra Wideband Analysis DPOFL-UWB X X DPOFL-XL02 Standard Extended record length ­ 31. 25M Samples/Ch X X X DPOFL-XL05 Extended record length ­ 62. 5M Samples/Ch X X X DPOFL-XL010 Extended record length ­ 125M Samples/Ch X X X DPOFL-XL020*8 Extended record length ­ 250M Samples/Ch 26 www. tektronix. com Digital and Mixed Signal Oscilloscopes -- DPO/DSA/MSO70000 Series Option DPO70000 DSA70000 MSO70000 Description TekExpress® Application Framework TEKEXP Opt. SATA-SI USB-RMT USB-TX*9, 11 XGbT X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X TekExpress Automation Framework HEAC Automated Solution SATA PHY/TSG/OOB Transmitter Tests for TekExpress SATA RSG/RMT Receiver Tests for TekExpress SATA Rx/Tx Channel Tests for TekExpress SATA TekExpress SW Bundle (TSG, RSG, RXTX for Hosts or Devices) SATA SI Cable Tests for TekExpress TekExpress Automated USB 3. 0 Receiver Solution TekExpress Automated USB 3. 0 Solution 10GBASE-T Automated Solution *4 Requires Ethernet Test Fixture. 2XL and a TCA-1MEG TekConnect 1 M buffer amplifier are recommended for use. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE TEKTRONIX MSO70000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual TEKTRONIX MSO70000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.