[. . . ] CHANNEL 1
CHANNEL 2
GATE
-50 -70 OFF dBu
CLOSE
COMPRESSOR / LIMITER
-20 0 -30 1. 5 -10 0
+10
AIR
1 2 -14 3 -20 dB -6 0
+6
GAIN REDUCTION(dB)
30 CH 1 20 15 10 6 4 2 1
GATE
-50 -70 -30 -15 -20 0 -30 1. 5
+10
COMPRESSOR / LIMITER
-10 0
+10
AIR
1 2 -14 3 -20 dB -6 0
+6
-30
-15
2
2. 5
5
10 81
50
100
0. 3 150 0. 1
0. 5
2
2. 5
5
10 81
50
100
0. 3 150 0. 1
0. 5
ON
+14
BY
+ 14
CH 2
OFF FULL
+10
-40 dBu
+20
1 n:1
LIM
0. 1 ms
200
50ms sec
+20
AUTO
CH 1
IN
AUTO
CH 2
IN
OFF dBu
-40 dBu
+20
1 n:1
LIM
0. 1 ms
200
50ms sec
+20
OFF
FULL
SQ·2
POWER
AUTO RATIO ATTACK
IN/OUT
CHAN 1 RELEASE OUTPUT
IN/OUT
CLOSE
AUTO RATIO ATTACK
IN/OUT
CHAN 2 RELEASE OUTPUT
IN/OUT
THRESHOLD
THRESHOLD
LEVEL
THRESHOLD
THRESHOLD
LEVEL
AC 100-120V, 60Hz AC 200-240V, 50HZ RATED INPUT: 12. 5W
SERIAL /DATE CODE
OUTPUT
BAL/ UNBAL
INPUT
BAL/ UNBAL
SIDE CHAIN
= INPUT TIP RING = OUTPUT SLEEVE = GROUND
OUTPUT
BAL/ UNBAL
INPUT
BAL/ UNBAL
SIDE CHAIN
= INPUT TIP RING = OUTPUT SLEEVE = GROUND
AC FUSE T 0. 315A
WWW. TAPCOGEAR. COM
BROUGHT TO YOU BY THE GROOVY FOLKS IN WOODINVILLE, WA, USA MANUFACTURED IN CHINA · "TAPCO" AND "MACKIE" ARE REGISTERED TRADEMARKS OF LOUD TECHNOLOGIES INC. · COPYRIGHT ©2003
CHANNEL 2
CHANNEL 1
by
CAUTION
AVIS
8.
RISK OF ELECTRIC SHOCK DO NOT OPEN RISQUE DE CHOC ELECTRIQUE NE PAS OUVRIR
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK) NO USER-SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED PERSONNEL
Heat -- This product should be situated away from heat sources such as radiators, or other devices which produce heat. Power Sources -- This product should be connected to a power supply only of the type described in these operation instructions or as marked on this product.
9.
ATTENTION: POUR EVITER LES RISQUES DE CHOC ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE. AVIS: POUR EVITER LES RISQUES D'INCENDIE OU D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE A LA PLUIE OU A L'HUMIDITE
The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. [. . . ] For example, if you are seeing an average gain reduction on the meter of about 6 dB, turn the OUTPUT control up to +6 dB to make up for it.
4. RATIO
The RATIO control determines the change in output level as a function of the change in input level, once the threshold has been crossed. It ranges from 1:1 (off) to LIM (full compression), where the compressor acts as a peak limiter and the signal stops increasing once it crosses the threshold. As an example of how the compressor works, if the RATIO is set to 2 (2:1), an increase in the input level of 10 dB results in a 5 dB increase in the output level (assuming the input signal is above the threshold level).
9. CHAN IN/OUT
This is a "bypass" switch that effectively disables the gate and compressor circuits. You can use this switch to compare the processed signal to the unprocessed signal. When the CHAN IN/OUT button is pushed in, the IN LED below the GAIN REDUCTION Meters lights.
9
1
GATE
-50 -70 OFF dBu
CLOSE
3
-20 0 -30 1. 5 -10 0
+10
4
2 2. 5
+20
COMPRESSOR / LIMITER
5 10 81 50 100 0. 3 150 0. 1 200 ms 50ms sec 3 0. 5 1 2 -14 -20 -6
5
CHANNEL 1
6
8
0
+6 + 14 +20
10
AIR
30 CH 1 CH 2 CH 1
OFF FULL
11
CHANNEL 2
12
GATE
-50 -70 -30 -15 -20 0 -30 1. 5
+10
GAIN REDUCTION(dB)
20 15 10 6 4 2 1
COMPRESSOR / LIMITER
-10 0
+10
AIR
1 2 -14 3 -20 dB -6 0
+6
-30
-15
2
2. 5
5
10 81
50
100
0. 3 150 0. 1
0. 5
ON
+ 14
BY
+10
-40 dBu
1 n:1
LIM
0. 1
CH 2
IN AUTO IN
AUTO
OFF dBu
-40 dBu
+20
1 n:1
LIM
0. 1 ms
200
50ms sec
+20
OFF
FULL
dB
SQ·2
POWER
AUTO
IN/OUT
CHAN 1
IN/OUT
CLOSE
AUTO
IN/OUT
CHAN 2
IN/OUT
THRESHOLD
2
THRESHOLD
RATIO
ATTACK
RELEASE
OUTPUT
LEVEL
THRESHOLD
THRESHOLD
RATIO
ATTACK
RELEASE
OUTPUT
LEVEL
7
9
AIR Filter
10. LEVEL
The AIR filter is a unique feature that restores brilliance and sizzle to compressed signals. It provides a high-frequency boost to the signal after the compression stage. It ranges from OFF to FULL, where FULL provides the maximum high-frequency boost. Certain instruments such as LOOK vocals, acoustic guitars, and brass instruments have a wide dynamic range. A musician uses this dynamic CLOSER range to accentuate the "feel" of a particular section in a song. Compression is the key to balancing these dynamic signals in a live sound system so they don't jump out in the mix during hard hitting sections or get lost in the softer passages. Unfortunately, compression also tends to dull an instrument's sound, and the sound, although more balanced, loses its sparkle. The AIR filter is a high-frequency shelving filter whose amplitude varies depending on the amount of compression applied to the signal. When softly compressing the signal, the AIR filter provides very little high-frequency boost (it's not really needed). When squeezing the signal hard with compression, the AIR filter has more high-frequency boost available. Experiment with the AIR LEVEL control to find the best sound for the particular instrument or voice being compressed.
When the signal is below the threshold and there is no compression taking place, there is no meter indication. As soon as the signal crosses the threshold and triggers the compressor, the meter LEDs begin to light from right to left, indicating more and more compression.
12. The LED above the switch lights when the power is on.
REAR PANEL FEATURES
13. [. . . ] Service and repairs of TAPCO products are to be performed only at the factory, OR at a factoryauthorized service center. Unauthorized service, repairs, or modification will void this warranty. and Authorized TAPCO Service Centers reserve the right to inspect any products that may be the subject of any warranty claims before repair or replacement is carried out. LOUD Technologies and Authorized TAPCO Service Centers may, at their option, require proof of the original date of purchase in the form of a dated copy of the original dealer's invoice or sales receipt. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE TAPCO SQUEEZ