User manual SUUNTO ESCAPE 203 QUICK GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUUNTO ESCAPE 203. We hope that this SUUNTO ESCAPE 203 user guide will be useful to you.


SUUNTO ESCAPE 203 QUICK GUIDE: Download the complete user guide (183 Ko)

You may also download the following manuals related to this product:

   SUUNTO ESCAPE 203 (161 ko)
   SUUNTO ESCAPE 203 (160 ko)
   SUUNTO ESCAPE 203 (165 ko)
   SUUNTO ESCAPE 203 (170 ko)
   SUUNTO ESCAPE 203 (206 ko)
   SUUNTO ESCAPE 203 (242 ko)
   SUUNTO ESCAPE 203 (199 ko)
   SUUNTO ESCAPE 203 QUICK GUIDE (170 ko)
   SUUNTO ESCAPE 203 QUICK GUIDE (160 ko)
   SUUNTO ESCAPE 203 QUICK GUIDE (199 ko)
   SUUNTO ESCAPE 203 QUICK GUIDE (165 ko)
   SUUNTO ESCAPE 203 QUICK GUIDE (206 ko)
   SUUNTO ESCAPE 203 QUICK GUIDE (161 ko)
   SUUNTO ESCAPE 203 QUICK GUIDE (242 ko)

Manual abstract: user guide SUUNTO ESCAPE 203QUICK GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] EN Escape203 Barometer Alarm Symbol Barometer Trend Indicator Altimeter/Barometer Alarm Symbol Low Battery Warning Field 3 Mode Indicator [-] -Button Field 1 Field 2 Field 4 Altimeter Function Indicator Weather Station Function Indicator [+] -Button Center Button TABLE OF CONTENTS 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LCD DISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Note: If no buttons are pushed within one minute after entering the setup, the device automatically exits the setup mode and the values displayed at this time will remain at the current settings. 13 3. ALTIMETER MODE [ALTI] The Altimeter mode provides you with: · Shows: altitude, altitude difference from start of hike/climb, time, ascent/descent rate in m/hour or ft/hour. · Altitude range: from -500 to 9, 000 m; from -1, 600 to 29, 500 ft. · Difference measurement function enables zeroing of Altimeter to follow vertical progress from start of hike/climb. · Up to 20 user-definable altitude points can be stored in memory for later viewing (information stored: # of point stored, altitude, date and time). Note: The Weather Station Function is discussed in Chapter 5 Barometer Mode. AS ALTITUDE IS CALCULATED BASED ON CHANGES IN BAROMETRIC PRESSURE, IT IS IMPORTANT TO SET THE REFERENCE ALTITUDE AT REGULAR INTERVALS. To view the Altimeter mode: If the triangle arrow is not pointing to ALTI, PRESS the [+] or [-] button until the triangle arrow is directly above ALTI on the mode bar. The display will show the following information: · Field 1 shows the vertical ascent/descent rate. · Field 4 shows the altitude difference from zeroing the Altimeter. 14 Note: If the user does not press any button for 20 hours in the [ALTI] mode, the unit will exit this mode and return to the main TIME mode. SETTING THE ALTIMETER Four settings can be performed when in [ALTI] mode: 1. Zeroing the altitude for altitude difference measurement (2nd display). Note: If no buttons are pushed within one minute after entering the setup, the Escape203 automatically exits the setup mode and the values displayed at this time will remain at the current settings. The factory or default setting equals a pressure of 1013. 5 hPa and an altitude of 0 meters. Setting the Reference Altitude Setting the unit using reference altitude leads to the most accurate altimeter readings. Beware that adjusting the reference altitude will affect the Barometer readings since sea level pressure and reference altitude are inter-related. Field 3 displays "REF" and in Field 2 the altitude reading will begin to flash. PRESS either the [+] button or the [-] button to numerically scroll up or down until the desired altitude is displayed. PRESS the Center button to accept the choice and move to next menu Zeroing the Altitude. 15 Note: It is not necessary to set or change each menu item. You can PRESS the Center button until the display menu item to adjust flashes. Once the desired changes has been made, PRESS and HOLD the Center button for 2 seconds to exit the setup mode. Then PRESS the Center button (once) until the text "dIFF" appears in Field 2 and "SEt" in Field 3. [. . . ] Viewing the Pressure and Temperature Information Scrolling through these displays will show you the development of the barometric pressure and temperature during the last 24 hours. The first display begins with information of the most current situation and it moves toward the situation recorded 24 hours ago. The information shown in these displays is temperature, sea level pressure, specific time of the measurement and absolute pressure. 28 The pressure and temperature information for the last 24 hours can be scrolled through in intervals of 30 minutes for the last three hours and thereafter in 3-hour intervals. Note: If the user does not press any button for 20 hours while viewing these memory displays, the unit will exit this mode and return to the main TIME mode. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUUNTO ESCAPE 203




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUUNTO ESCAPE 203 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.