User manual SUPERMICRO MBD-X8DTH-6F-O

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUPERMICRO MBD-X8DTH-6F-O. We hope that this SUPERMICRO MBD-X8DTH-6F-O user guide will be useful to you.


SUPERMICRO MBD-X8DTH-6F-O : Download the complete user guide (7601 Ko)

Manual abstract: user guide SUPERMICRO MBD-X8DTH-6F-O

Detailed instructions for use are in the User's Guide.

[. . . ] This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. [. . . ] The default 1-2 SAS Enabled (Default) setting is Pins 1-2 to enable the connec2-3 SAS Disabled tion. Note: For information on LSI SAS RAID configuration, please refer to the LSI MegaRAID User's Guide @ http://www. supermicro. com/support/ manuals/. KB/MOUSE FAN5 P1-DIMM3A P1-DIMM3B USB 0/1 IPMI LAN FAN6 P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 FAN7 CPU1 Fan JPI2C1 JPW1 JPW2 JPW3 FAN1 COM1 A. SAS Enable (X8DT6/ MBD-X8DTH-6F-O VGA PHY LE1 LAN1 CP CPU1 P2-DIMM1B P2-DIMM1A LAN2 P2-DIMM2B P2-DIMM2A FAN8/ CPU2 Fan SLOT7 PCI-E 2. 0 X8 P2-DIMM3B P2-DIMM3A JOH1 JD1 FAN3 SP1 LAN CTRL JPL1 FAN2 X8DT6/E Series Rev. 2. 01 SLOT6 PCI-E 2. 0 X8 Intel 5520 LAN CTRL BIOS SIO SLOT4 PCI-E 2. 0 X8 JPL2 JBT1 Intel ICH10R LED1 J5 SAS0~3 SLOT3 PCI-E 2. 0 X4 BMC CTRL Battery South Bridge TPM JP7 LSI 2008 JIBTN1 SAS CTRL SAS4~7 D1 T-SGPIO1 SLOT1 PCI-E X4 JI2C2 JI2C1 JPB JPG1 COM2 USB6/7 USB4/5 USB3 USB2 I-SATA4 I-SATA3 I-SATA1 I-SATA0 JWF1 JWD JL1 JPS1 2-28 FAN4 JWOL T-SGPIO2 I-SATA5 I-SATA2 A FLOPPY SLOT5 PCI-E 2. 0 X8 IOH JF1 Chapter 2: Installation CMOS Clear JBT1 is used to clear CMOS. Instead of pins, this "jumper" consists of contact pads to prevent the accidental clearing of CMOS. To clear CMOS, use a metal object such as a small screwdriver to touch both pads at the same time to short the connection. Note: For an ATX power supply, you must completely shut down the system, remove the AC power cord and then short JBT1 to clear CMOS. Watch Dog Enable/Disable Watch Dog (JWD) is a system monitor that can reboot the system when a software application hangs. Close Pins 2-3 to generate a non-maskable interrupt signal for the application that hangs. Watch Dog must also be enabled in the BIOS. Watch Dog Jumper Settings (JWD) Jumper Setting Pins 1-2 Pins 2-3 Open Definition Reset (default) NMI Disabled A. Clear CMOS KB/MOUSE FAN5 P1-DIMM3A P1-DIMM3B USB 0/1 IPMI LAN FAN6 P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 FAN7 CPU1 Fan JPI2C1 JPW1 JPW2 JPW3 FAN1 B. Watch Dog Enable COM1 VGA PHY LE1 LAN1 CP CPU1 P2-DIMM1B P2-DIMM1A LAN2 P2-DIMM2B P2-DIMM2A FAN8/ CPU2 Fan SLOT7 PCI-E 2. 0 X8 P2-DIMM3B P2-DIMM3A JOH1 JD1 FAN3 SP1 LAN CTRL JPL1 FAN2 X8DT6/E Series Rev. 2. 01 SLOT6 PCI-E 2. 0 X8 Intel 5520 LAN CTRL BIOS SIO SLOT4 PCI-E 2. 0 X8 JPL2 JBT1 Intel ICH10R LED1 SAS0~3 A J5 SLOT3 PCI-E 2. 0 X4 BMC CTRL Battery South Bridge TPM JP7 LSI 2008 D1 COM2 SLOT1 PCI-E X4 JI2C2 JI2C1 JPB JPG1 USB6/7 USB4/5 USB3 USB2 I-SATA4 I-SATA3 I-SATA1 I-SATA0 JWF1 JWD JL1 JPS1 2-33 FAN4 JWOL B C JIBTN1 T-SGPIO1 T-SGPIO2 I-SATA5 I-SATA2 SAS CTRL SAS4~7 FLOPPY SLOT5 PCI-E 2. 0 X8 IOH JF1 X8DT6/MBD-X8DTH-6F-O/X8DTE/X8DTE-F User's Manual Onboard Power LED An Onboard Power LED is located at LE1 on the motherboard. Be sure to turn off the system and unplug the power cord before removing or installing components. See the tables at right for more information. Green Onboard PWR LED (LE1) Settings LED Color Off Definition System Off (PWR cable not connected) System Power On A. Onboard Power LED KB/MOUSE FAN5 P1-DIMM3A P1-DIMM3B USB 0/1 IPMI LAN FAN6 P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 FAN7 CPU1 Fan JPI2C1 JPW1 JPW2 JPW3 FAN1 COM1 VGA PHY JF1 LE1 LAN1 CP CPU1 P2-DIMM1B P2-DIMM1A LAN2 P2-DIMM2B P2-DIMM2A FAN8/ CPU2 Fan SLOT7 PCI-E 2. 0 X8 P2-DIMM3B P2-DIMM3A JOH1 JD1 FAN3 SP1 LAN CTRL JPL1 A FAN2 X8DT6/E Series Rev. 2. 01 SLOT6 PCI-E 2. 0 X8 Intel 5520 LAN CTRL BIOS SIO SLOT4 PCI-E 2. 0 X8 JPL2 JBT1 Intel ICH10R LED1 J5 SAS0~3 SLOT3 PCI-E 2. 0 X4 BMC CTRL Battery South Bridge TPM JP7 LSI 2008 JIBTN1 SAS CTRL SAS4~7 D1 T-SGPIO1 SLOT1 PCI-E X4 JI2C2 JI2C1 JPB JPG1 COM2 USB6/7 USB4/5 USB3 USB2 I-SATA4 I-SATA3 I-SATA1 I-SATA0 JWF1 JWD JL1 JPS1 2-34 FAN4 JWOL T-SGPIO2 I-SATA5 I-SATA2 FLOPPY SLOT5 PCI-E 2. 0 X8 IOH Chapter 2: Installation 2-9 Floppy Drive, Serial ATA and SAS Connections Note the following when connecting the floppy and hard disk drive cables: • • • The floppy disk drive cable has seven twisted wires. A single floppy disk drive ribbon cable has 34 wires and two connectors to provide for two floppy disk drives. The connector with twisted wires always connects to drive A, and the connector that does not have twisted wires always connects to drive B. Floppy Drive Connector Pin Definitions Pin# 1 3 5 Definition Ground Ground Key Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Pin # 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Definition FDHDIN Reserved FDEDIN Index Motor Enable Drive Select B Drive Select B Motor Enable DIR STEP Write Data Write Gate Track 00 Write Protect Read Data Side 1 Select Diskette Floppy Connector The floppy connector is located next to the Super I/O chip on the motherboard. See the table on the right for pin definitions. 7 9 11 13 15 17 19 21 23 25 27 29 31 33 KB/MOUSE FAN5 P1-DIMM3A P1-DIMM3B USB 0/1 IPMI LAN FAN6 P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 FAN7 CPU1 Fan JPI2C1 JPW1 JPW2 JPW3 FAN1 A. Floppy COM1 VGA PHY LE1 LAN1 CP CPU1 P2-DIMM1B P2-DIMM1A LAN2 P2-DIMM2B P2-DIMM2A FAN8/ CPU2 Fan SLOT7 PCI-E 2. 0 X8 P2-DIMM3B P2-DIMM3A JOH1 JD1 FAN3 SP1 LAN CTRL JPL1 FAN2 X8DT6/E Series Rev. 2. 01 SLOT6 PCI-E 2. 0 X8 Intel 5520 FLOPPY SLOT5 PCI-E 2. 0 X8 LAN CTRL BIOS IOH SIO JF1 A SLOT4 PCI-E 2. 0 X8 JPL2 JBT1 Intel ICH10R LED1 J5 SAS0~3 SLOT3 PCI-E 2. 0 X4 BMC CTRL Battery South Bridge TPM JP7 LSI 2008 JIBTN1 SAS CTRL SAS4~7 D1 T-SGPIO1 SLOT1 PCI-E X4 JI2C2 JI2C1 JPB JPG1 COM2 USB6/7 USB4/5 USB3 USB2 I-SATA4 I-SATA3 I-SATA1 I-SATA0 JWF1 JWD JL1 JPS1 2-35 FAN4 JWOL T-SGPIO2 I-SATA5 I-SATA2 X8DT6/MBD-X8DTH-6F-O/X8DTE/X8DTE-F User's Manual Serial ATA Ports Six Serial ATA Ports (I-SATA0~ISATA 5) are located on the motherboard. These ports provide serial-link signal connections, which are faster than the connections of Parallel ATA. [. . . ] Then, select OK to allow the AMI BIOS to automatically load Optimal Defaults to the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications. Load Fail-Safe Defaults To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. The Fail-Safe settings are designed for maximum system stability, but not for maximum performance. 4-27 X8DT6/MBD-X8DTH-6F-O/X8DTE/X8DTE-F User’s Manual Notes 4-28 Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUPERMICRO MBD-X8DTH-6F-O




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUPERMICRO MBD-X8DTH-6F-O will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.