User manual SUPERMICRO MBD-X7SPA-HF-D525

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SUPERMICRO MBD-X7SPA-HF-D525. We hope that this SUPERMICRO MBD-X7SPA-HF-D525 user guide will be useful to you.


SUPERMICRO MBD-X7SPA-HF-D525 : Download the complete user guide (7601 Ko)

Manual abstract: user guide SUPERMICRO MBD-X7SPA-HF-D525

Detailed instructions for use are in the User's Guide.

[. . . ] This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license. BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. SHALL NOT HAVE LIABILITY FOR ANY HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH HARDWARE, SOFTWARE, OR DATA. Any disputes arising between manufacturer and customer shall be governed by the laws of Santa Clara County in the State of California, USA. [. . . ] Watch Dog must also be enabled in the BIOS. Watch Dog Jumper Settings (JWD) Jumper Setting Pins 1-2 Pins 2-3 Open Definition Reset (default) NMI Disabled Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only) JPW2 P1-DIMM3A JPW3 J6 KB/MOUSE A. Clear CMOS JPW1 Fan1 USB 0/1 P1-DIMM3B P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 B. Watch Dog Enable COM1 Fan7/ CPU2 SP1 VGA JLAN1 LAN1 LAN3 P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A LE1 CPU1 JLAN2 LAN2 LAN4 JF1 Fan3 SI/O TPM Header LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5 Floppy Fan4 LSI 1068E JSM2 (*X8DT3 Models only) JL1 JWD JPS1JPS2 Fan2 P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 LAN SPEC X8DT3/i Series Rev. 2. 01 CTRL Slot5 PCI-E 2. 0x8 in x16 Intel 5520 North Bridge Slot4 PCI-E 2. 0 x16 LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz BIOS JBT1 Slot2 PCI-E x4 JI2C1 JI2C2 Slot1 PCI 33MHz COM2 JPL1 JPL2 J28 J27 A ICH10R South Bridge T-SGPIO2 T-SGPIO1 I-BUTTON JP7 I-SATA5 I-SATA3 BMC/VGA CTRL Battery JP3 JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2 USB3 USB2 I-SATA4 I-SATA2 I-SATA0 2-30 JWOL I-SATA1 JWF1 B JSM1 D1 JD1 1 1 1 Fan8/ CPU1 FAN JOH1 Chapter 2: Installation I2C Bus to PCI-Exp. Slots Jumpers JI2C1 and JI2C2 allow you to connect the System Management Bus (I2C) to PCI-Express slots. See the table on the right for jumper settings. I2C to PCI-Exp Jumper Settings Jumper Setting 1-2 2-3 Definition Enabled Disabled (Default) VGA Enable Jumper JPG1 allows the user to enable the onboard VGA connector. See the table on the right for jumper settings. VGA Enable Jumper Settings Jumper Setting 1-2 2-3 Definition Enabled (Default) Disabled J6 KB/MOUSE Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only) JPW2 P1-DIMM3A JPW3 A. VGA Enable Fan7/ CPU2 SP1 VGA COM1 JLAN1 LAN1 LAN3 P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A LE1 CPU1 JLAN2 LAN2 LAN4 JF1 Fan3 SI/O TPM Header LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5 Floppy Fan4 LSI 1068E JSM2 (*X8DT3 Models only) JSM1 JWOL JL1 JWD JPS1JPS2 Fan2 1 1 1 P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 LAN SPEC X8DT3/i Series Rev. 2. 01 CTRL Slot5 PCI-E 2. 0x8 in x16 Intel 5520 North Bridge Slot4 PCI-E 2. 0 x16 LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz BIOS JBT1 Slot2 PCI-E x4 BMC/VGA CTRL ICH10R South Bridge T-SGPIO2 T-SGPIO1 I-BUTTON JP7 I-SATA5 USB3 USB2 I-SATA4 I-SATA2 I-SATA0 I-SATA3 I-SATA1 JWF1 Battery JI2C1 JI2C2 A COM2 JPL1 JPL2 JP3 B Slot1 PCI 33MHz J28 J27 C D1 JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2 2-31 JD1 Fan8/ CPU1 FAN JOH1 X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual SAS Enable/Disable (X8DT3/ X8DT3-F/X8DT3-LN4F only) Jumper JPS1 allows you to enable or disable the onboard SAS connections. See the table on the right for jumper settings. 1-2 2-3 SAS Enable Jumper Settings Jumper Setting Definition SAS Enabled (Default) SAS Disabled SAS RAID Select (X8DT3/X8DT3-F/ X8DT3-LN4F only) Jumper JPS2 allows you to select RAID Configuration settings for the onboard SAS connections. Select Jumper Settings Jumper Setting Open Closed Definition Integrated Target Mode (IT) Software RAID (SR) (Default) Note: For more information on LSI SAS RAID configuration, please refer to the LSI MegaRAID User's Guide posted on our website @ http://www. A • single floppy disk drive ribbon cable has 34 wires and two connectors to A provide for two floppy disk drives. The connector with twisted wires always connects to drive A, and the connector that does not have twisted wires always connects to drive B. Floppy Drive Connector Pin Definitions Pin# 1 3 5 Definition Ground Ground Key Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Ground Pin # 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Definition FDHDIN Reserved FDEDIN Index Motor Enable Drive Select B Drive Select B Motor Enable DIR STEP Write Data Write Gate Track 00 Write Protect Read Data Side 1 Select Diskette Floppy Connector The floppy connector is located next to the Super I/O chip on the motherboard. See the table on the right for pin definitions. 7 9 11 13 15 17 19 21 23 25 27 29 31 33 Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only) JPW2 P1-DIMM3A JPW3 J6 KB/MOUSE JPW1 Fan1 A. Floppy USB 0/1 P1-DIMM3B P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 COM1 Fan7/ CPU2 SP1 VGA JLAN1 LAN1 LAN3 P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A LE1 CPU1 JLAN2 LAN2 LAN4 JF1 Fan3 Fan2 1 1 P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 LAN SPEC X8DT3/i Series Rev. 2. 01 CTRL Slot5 PCI-E 2. 0x8 in x16 Intel 5520 North Bridge SI/O Floppy JD1 Slot4 PCI-E 2. 0 x16 Fan8/ CPU1 FAN JOH1 A 1 LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz BIOS JBT1 Slot2 PCI-E x4 JI2C1 JI2C2 Slot1 PCI 33MHz COM2 JPL1 JPL2 J28 J27 TPM Header LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5 BMC/VGA CTRL ICH10R South Bridge T-SGPIO2 T-SGPIO1 I-BUTTON JP7 I-SATA5 I-SATA3 LSI 1068E (*X8DT3 Models only) I-SATA1 JWF1 JSM2 Battery JSM1 JWOL D1 JP3 JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2 USB3 USB2 JL1 JWD JPS1JPS2 I-SATA4 I-SATA2 I-SATA0 Fan4 2-37 X8DT3/X8DTi/X8DT3-F/X8DTi-F/X8DT3-LN4F/X8DTi-LN4F User's Manual Serial ATA Ports Six Serial ATA Ports (I-SATA0~I-SATA 5) are located at JS1~JS6 on the motherboard. These ports provide serial-link signal connections, which are faster than the connections of Parallel ATA. SAS Ports (X8DT3/X8DT3-F/ X8DT3-LN4F only) SAS Ports 0~3, 4~7, located at JSM1/ JSM2, provide Serial-Attached SCSI connections on the X8DT3/X8DT3-F/ X8DT3-LN4F. See the layout below for SAS port locations. Pin# 1 2 3 4 5 6 7 Serial ATA Pin Definitions Definition Ground TX_P TX_N Ground RX_N RX_P Ground Note 1: For more information on SATA HostRAID configuration, please refer to the Intel SATA HostRAID User's Guide posted on our website @ http://www. supermicro. com/support/manuals/. Note 2: For more information on LSI SAS RAID configuration, please refer to the LSI MegaRAID User's Guide posted on our website @ http:// www. supermicro. com/support/manuals/. KB/MOUSE Fan5 Fan6 Dedicated LAN (X8DT3/i-F/-LN4F only) JPW2 P1-DIMM3A Fan1 P1-DIMM3B P1-DIMM2A P1-DIMM2B P1-DIMM1A P1-DIMM1B CPU2 JPW3 A. SAS 4~7 (X8DT3/-F/-LN4F only) 1 COM1 Fan7/ CPU2 SP1 VGA JLAN1 LAN1 LAN3 P2-DIMM1B P2-DIMM1A P2-DIMM2B P2-DIMM2A P2-DIMM3B P2-DIMM3A Slot6 PCI-E 2. 0x8 SPEC LE1 CPU1 JLAN2 LAN2 LAN4 Fan3 Intel 5520 North Bridge SI/O Floppy TPM Header BIOS JBT1 LES2 LES1 (*X8DT3 Models only) SAS4~7 SAS0~3 J5 ICH10R South Bridge T-SGPIO2 T-SGPIO1 LSI JSM2 1068E I-BUTTON JP7 JF1 Fan2 1 1 LAN X8DT3/i Series Rev. 2. 01 CTRL Slot5 PCI-E 2. 0x8 in x16 Slot4 PCI-E 2. 0 x16 LAN CTRL (X8DT3/i-LN4F) Slot3 PCI 33 MHz Slot2 PCI-E x4 JI2C1 JI2C2 Slot1 PCI 33MHz COM2 JPL1 JPL2 BMC/VGA CTRL JD1 Fan8/ CPU1 FAN JOH1 H G Fan4 Battery F D I-SATA3 J28 J27 JP3 JPB USB6/7 USB4/5 JPG1 JUSB3 JUSB2 USB3 USB2 JL1 JWD JPS1JPS2 I-SATA4 I-SATA2 I-SATA0 E C A 2-38 JWOL I-SATA5 D1 I-SATA1 JWF1 B (*X8DT3 Models only) JSM1 Chapter 3: Troubleshooting Chapter 3 Troubleshooting 3-1 Troubleshooting Procedures Use the following procedures to troubleshoot your system. [. . . ] Load Optimal Defaults To set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK to allow the AMI BIOS to automatically load Optimal Defaults to the BIOS Settings. The Optimal settings are designed for maximum system performance, but may not work best for all computer applications. Load Fail-Safe Defaults To set this feature, select Load Fail-Safe Defaults from the Exit menu and press <Enter>. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SUPERMICRO MBD-X7SPA-HF-D525




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SUPERMICRO MBD-X7SPA-HF-D525 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.