User manual SIMRAD TRANSDUCER MOUNTING PLATE SCHEMA REV A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIMRAD TRANSDUCER MOUNTING PLATE. We hope that this SIMRAD TRANSDUCER MOUNTING PLATE user guide will be useful to you.


SIMRAD TRANSDUCER MOUNTING PLATE SCHEMA REV A: Download the complete user guide (90 Ko)

Manual abstract: user guide SIMRAD TRANSDUCER MOUNTING PLATESCHEMA REV A

Detailed instructions for use are in the User's Guide.

[. . . ] Improper use or maintenance may cause damage to the equipment and/or injury to personnel. The user must be familiar with the contents of the appropriate manuals before attempting to install, operate or work on the equipment. Kongsberg Maritime AS disclaims any responsibility for damage or injury caused by improper installation, use or maintenance of the equipment. Support information If you require maintenance or repair, contact your local dealer. On the web site you will also find a list of our dealers and distributors. Kongsberg Maritime AS www. kongsberg. com Installation manual Table of contents ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] If no Ethernet port is available, an Ethernet switch may be inserted between the computer and the transceiver. b Connect an Ethernet cable from the TRANSDUCER MOUNTING PLATE computer to the peripheral system. We strongly recommend that you use high quality Ethernet cables, minimum CAT-5. RJ45 Ethernet, straight on page 40 3 Click the Setup icon under the Main menu to open the Setup sub-menu. 4 Click Navigation to open the Navigation dialog. 5 For each tab: a b c Select which port to use. Click Setup for the selected port to define the communication parameters. If you choose Auto, the TRANSDUCER MOUNTING PLATE will automatically choose among the incoming information according to a predefined priority list. d If applicable, define the Talker ID. 6 Click OK to save the current settings and close the dialog. 58 328459/A Drawing file Drawing file This chapter contains relevant drawings related to the electrical and physical installation of the Simrad TRANSDUCER MOUNTING PLATE. Note The mechanical drawings are for information and guidance only. The original installation drawings are available on PDF and/or AutoCad's DWG format. Visit www. simrad. com to download. Topics · · · TRANSDUCER MOUNTING PLATE Marine computer on page 60 TRANSDUCER MOUNTING PLATE Receiver Unit on page 61 Power Supply for TRANSDUCER MOUNTING PLATE Receiver Unit on page 62 328459/A 59 Simrad TRANSDUCER MOUNTING PLATE TRANSDUCER MOUNTING PLATE Marine computer 60 328459/A Drawing file TRANSDUCER MOUNTING PLATE Receiver Unit 328459/A 61 Simrad TRANSDUCER MOUNTING PLATE Power Supply for TRANSDUCER MOUNTING PLATE Receiver Unit 62 328459/A Technical specifications Technical specifications This chapter lists the main technical specifications for the Simrad TRANSDUCER MOUNTING PLATE. Note We reserve the right to alter technical specifications without prior notice. Related topics · Catch monitoring system specifications on page 63 · Interface specifications on page 64 · Colour display specifications on page 64 · TRANSDUCER MOUNTING PLATE Marine Computer specifications on page 65 Catch monitoring system specifications · · · · Communication channels: Maximum 30 channels Communication frequencies: 43, 5 to 49, 5 kHz Maximum number of communication channels in simultaneous use: 6 Single channel sensor types: ­ ­ ­ ­ ­ ­ ­ ­ · PI Catch [and PI Rip] PI Depth PI Temperature PI Bottom Contact PI Height PI Remote/Depth PI Geometry Differential PI Spread Dual channel sensor types: ­ PI Temperature/Depth ­ PI Height/Depth [and PI SeineSounder] ­ PI Spread/Depth 328459/A 63 Simrad TRANSDUCER MOUNTING PLATE ­ PI Twin Spread ­ PI Geometry · Secondary data based on sensor information: ­ Vertical geometry [using a depth sensor on each trawl door] ­ Total water depth [using one height and one depth sensor] ­ Trawl opening [using information added to the PI Height setup] · · Sensor update rate: Individually adjusted on each sensor to Fast, Normal or Slow Presentation modes: ­ Sensor views [alphanumerical with history views] ­ Trend views [historical values presented in graphs] · · User settings: Unlimited (except by hard disk capacity) Information storage: Unlimited (except by hard disk capacity) number of screen captures Interface specifications Numerous external interfaces are provided for the Simrad TRANSDUCER MOUNTING PLATE. · · Outputs: ­ PI data (proprietary telegram formats) Inputs: ­ Navigation data (NMEA format) ­ Depth (NMEA format) ­ ITI data (proprietary telegram formats) Colour display specifications Commercial display The Simrad TRANSDUCER MOUNTING PLATE may be supplied with one of several commercial displays, and several sizes are available. · On a Danish seine the Simrad PI Bottom Contact sensor will let you know when the net has a stable bottom contact, and when it is time to haul. 328459/A 69 Simrad TRANSDUCER MOUNTING PLATE PI Catch purpose and application This is an S-type PI sensor. To charge this sensor, use the Simrad PI Charger or the Simrad PI MiniCharger. Figure 11 PI Catch application Using the Simrad PI Catch sensor, you can easily monitor the filling rate and the amount of catch in the trawl. The sensor simply monitors the expansion of the meshes in the cod-end. Once the volume caught is enough to expand the meshes, they will pull the detector wires and engage the sensor. The sensitivity of the sensor can easily be adjusted by extending the detection rubber bands to span additional meshes. To monitor the filling rate, we recommend that you use minimum two sensors. Place the first sensor at the far end of the cod-end, it will tell you that the trawl is actually fishing. Once the trawl is filled to the chosen location, the sensor is engaged, and you know that it is time to haul. 70 328459/A PI sensors PI Depth purpose and application This is an S-type PI sensor. To charge this sensor, use the Simrad PI Charger or the Simrad PI MiniCharger. Figure 12 PI Depth application The Simrad PI Depth sensor provides information about the current depth and the depth changes of your gear. [. . . ] · Unless it is absolutely unavoidable, cables should not be installed across the vessel's expansion joints. If the situation is unavoidable, a loop of cable having a length proportional to the possible expansion of the joint must be provided. The minimum internal radius of the loop must be at least twelve times the external diameter of the cable. · Where a service requires duplicate supply lines, the cables must follow separate paths through the vessel whenever possible. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD TRANSDUCER MOUNTING PLATE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD TRANSDUCER MOUNTING PLATE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.