User manual SIMRAD SP60 REV D

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIMRAD SP60. We hope that this SIMRAD SP60 user guide will be useful to you.


SIMRAD SP60 REV D: Download the complete user guide (2948 Ko)

Manual abstract: user guide SIMRAD SP60REV D

Detailed instructions for use are in the User's Guide.

[. . . ] Operator manual Simrad SP60 Low frequency fishery sonar www. simrad. com MAXIMIZING YOUR PERFORMANCE AT SEA 850-164575 / Rev. D SP60 Low frequency fishery sonar Operator manual WARNING The sonar must never be powered up when the ship is in dry dock. To prevent inadvertent use of the sonar, pull out the mains plug on the Sonar Processor Unit whenever the vessel is in dry dock. About this document Rev Rev. D Date 25. 11. 04 Written by RBr Checked by SØJ Approved by OBG Changed to reflect new software version 1. 2. X. © 2004 Simrad AS ISBN 82-8066-008-9 All rights reserved. No part of this work covered by the copyright hereon may be reproduced or otherwise copied without prior permission from Simrad AS. The information contained in this document is subject to change without prior notice. [. . . ] The Temporary menus must however be removed manually using the Close button in the bottom of menu. All Temporary menus have access to on-line help through a Help button. Temporary menus Cosmetics, page 64 Store/Recall, page 65 Test, page 66 Sort Modes, page 68 850-164575 / Rev. D 63 Simrad SP60 Cosmetics The Cosmetics menu is activated by pressing the Cosmetics button in the Display menu. It provides access to various parameters controlling the appearance of the sonar picture. All the functions - except Track history - are on/off buttons. Cosmetic parameters Slant Range / True Range, page 133 Bearing Card, page 50 Compass Card, page 51 Distance Rings, page 50 VRM (Variable Range Marker), page 51 Bow Marker, page 52 Track History, page 142 Minute Marker, page 52 Wind Marker, page 50 Vertical Ring, page 51 Depth dividers, page 52 The Close button closes this menu. The Help button opens the on-line help. 64 850-164575 / Rev. D Menu description Store/Recall The Store/Recall menu is activated by the Store/Recall button in the Setup menu. The Store/Recall menu is used to store single display pictures or a sequence or pictures. The stored pictures can easily be recalled for evaluation or comparing schools. Store/Recall parameters Store - This is the "record" button to start the storage sequence. Print - Allows you to print the stored picture to the default printer (if any). The following other parameters are available: Store, page 138 Store Mode, page 138 Recall, page 125 Recall Mode, page 125 The Close button closes this menu. The Help button opens the on-line help. 850-164575 / Rev. D 65 Simrad SP60 System test The System test menu is activated by the Test button in the Setup menu. The System test menu provides several test routines available to perform operational and functional tests. These tests are designed only to be carried out by qualified service engineers. Test parameters Test Configuration - This function is only to be activated by qualified service engineers. Test Function - This function is only to be activated by qualified service engineers. Toggle TxPower - This function is only to be activated by qualified service engineers. Test Beam - This function is only to be activated by qualified service engineers. Echo Level - This button provides a readout of the current noise in the waters surrounding the vessel. This noise is caused by air bubbels, water flow and mechnical disturbances from hull and engine. In order to obtain the besst possible sonar result, the noise level readout should be as close to 0. 0 dB as possible. Roll - This is not a button, it is a readout from the sensor of the actual roll value at the time of the last transmission. Pitch - This is not a button, it is a readout from the sensor of the actual pitch value at the time of the last transmission. TRU Temp- This button provides a readout of the current temperature inside the Transceiver Unit. If the temperature rises to unacceptable levels, and alarm will be given. [. . . ] The hoist/lower motor will automatically stop when the transducer shaft reaches the upper or lower limit switch. Remember to set the hoisting/lowering switch back to Remote for normal operation. 160 850-164575 / Rev. D On-board maintenance Cleaning the transducer The transducer normally needs little attention. However, the transducer face should be inspected and cleaned whenever the vessel is in dock. To lower the transducer when in dock, use the hoist/lower switch S302 in the Motor Control Unit (mounted on the gantry). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD SP60




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD SP60 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.