User manual SIMRAD OUTLINE DIMENSIONS ES70-11 SCHEMA REV A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SIMRAD OUTLINE DIMENSIONS ES70-11. We hope that this SIMRAD OUTLINE DIMENSIONS ES70-11 user guide will be useful to you.


SIMRAD OUTLINE DIMENSIONS ES70-11 SCHEMA REV A: Download the complete user guide (26 Ko)

Manual abstract: user guide SIMRAD OUTLINE DIMENSIONS ES70-11SCHEMA REV A

Detailed instructions for use are in the User's Guide.

[. . . ] to either repair or replace any unit/part that fails within the limits of the Warranty Policy. The Warranty Policy is only valid on new equipment Replacement of parts, components, and/or PCB Boards during a warranty repair does not extend the original warranty period. Consumable Materials: · Consumable materials, such as lamps, fuses, o-rings, gaskets and batteries, shall not be replaced free of charge. Kongsberg Simrad Mesotech Ltd. Port Coquitlam, BC - Canada 974-25007001/2. 0 Page 2 SL 30/35 Hull Sonar Operators Manual List of Contents Warranty Service: · Warranty service is available worldwide through authorized Kongsberg Group Companies, Simrad Distributors, Dealers or Agencies. When requesting warranty service, you must supply the following information: 1. [. . . ] Use the slider controls or the increase-decrease buttons for either adjustment. Tilt controls allow you to control the tilt angle of the transducer up or down. The Auto Tilt Step option enables the automatic stepping of the tilt axis at the end of each azimuth sector sweep. As an example, if this option is enabled, after the azimuth axis has stepped through its complete sector width, the tilt axis is stepped by as much as its Step size, and the azimuth starts to sweep back its sector width in the reverse direction. These limits are equivalent to sector width and heading and determine the sweep sector of the tilt. Stabilization control enables the automatic tilt angle adjustment with the overall Pitch and Roll angle of the head. If the head is equipped with pitch and roll sensors, then prior to each acoustic ping the head reads its pitch and roll angle, calculates the offsets required to maintain the transducer at its desired angle and changes the tilt angle to compensate. 4. 59. 6. 2 Head Settings: Transmit The Head Settings: Transmit page is used to determine how the head transmits and receives. Kongsberg Simrad Mesotech Ltd. Port Coquitlam, BC - Canada 974-25007001/2. 0 Page 4. 54 SL 30/35 Hull Sonar Operators Manual Menu and Software Description The Uplink Baud Rate control is used to set the rate at which data is sent from the head to the surface. You will normally want to set this control to as high a rate as your system will support without generating too many errors. When Compression is set to On, the color depth of the sonar image will be an eighth of its maximum through a reduction in the signal amplitude resolution. This however, increases the uplink speed of the sonar data, thereby increasing system performance. Calibration data is not displayed for non-rotation heads such as altimeters The optical sensors are used to estimate the current rotational angle of the transducer within the dome. The CW and CCW columns are the detected ClockWise and CounterClockWise position of the optical sensors with respect to the 0 degree reference marker on the head. Theoretically the CW and CCW values should be the same and at perfect 0, 400, 800 and 1200 (corresponding to 0, 90, 180 and 270 degrees respectively). However, due to optical sensor mounting errors the positions do not match the perfect counts. Also due to the optical view field of the sensors, the CW and CCW values are not equal. Variation between the CW and CCW at each quadrant should be less than 20. Positional errors of each quad from its perfect value should be less than 35. Values outside these limits should be reported to Kongsberg Simrad Mesotech or its representatives. Example: Ref 0 90 CW 0 390 CCW 1596 415 normal abnormal, but operable Kongsberg Simrad Mesotech Ltd. Port Coquitlam, BC - Canada SL 30/35 Hull Sonar Operators Manual Menu and Software Description 974-25007001/2. 0 Page 4. 57 180 270 825 1190 845 1201 severely abnormal normal In the above example, at 0 degree reference angle, everything seems to be normal. At 90 degrees reference angle, the CW position is within acceptable tolerances (only 10 steps away from perfect, the acceptable deviation is 35) The CCW is also acceptable. [. . . ] The Distributed COM Configuration Properties dialog box should appear. Select the Default Properties page and set it up as follows. 6. 3. Go to Application page and select OUTLINE DIMENSIONS ES70-11-35 from the "Distributed COM Configuration Properties list of registered applications. Kongsberg Mesotech Ltd. Port Coquitlam, BC - Canada SL 30/35 Hull Sonar Surface Processor Setup Instructions 901-10111802 / Issue 1. 4 Page 8 6. 4. Press the "Properties. . . " button. The "OUTLINE DIMENSIONS ES70-11-35 Properties" dialog box should appear. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SIMRAD OUTLINE DIMENSIONS ES70-11




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SIMRAD OUTLINE DIMENSIONS ES70-11 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.