User manual SILENT KNIGHT REGENCY 4724C-ZONE EXPANDER

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SILENT KNIGHT REGENCY 4724C-ZONE EXPANDER. We hope that this SILENT KNIGHT REGENCY 4724C-ZONE EXPANDER user guide will be useful to you.


SILENT KNIGHT REGENCY 4724C-ZONE EXPANDER : Download the complete user guide (228 Ko)

Manual abstract: user guide SILENT KNIGHT REGENCY 4724C-ZONE EXPANDER

Detailed instructions for use are in the User's Guide.

[. . . ] MODEL 4734 SECURITY SYSTEM OWNER'S MANUAL TABLE OF CONTENTS 1 1. 1 1. 2 1. 3 1. 4 1. 5 1. 6 1. 7 1. 8 1. 9 Page 1 1 1 3 5 6 7 9 9 11 SYSTEM OVERVIEW Introduction System components Features Types of alarms Other audible signals Access codes Model 3825 touchpad System status lights Touchpad function buttons 2 2. 1 2. 2 2. 3 2. 4 2. 5 2. 6 2. 7 2. 8 2. 9 2. 10 2. 11 2. 12 2. 13 2. 14 2. 15 2. 16 2. 17 2. 18 2. 19 SYSTEM OPERATIONS If you make a mistake Entering access codes Arming the system (single-area system) Disarming the system (single-area system) Controlling auto-arming Arming/disarming (multi-area system) Bypassing a zone Unbypassing a zone Viewing system status Resetting an alarm Silencing (muting) a trouble condition Viewing alarm memory Viewing event history Enabling special features Access codes Setting the time (and date) Access 4300 system System testing Quick reference guide 12 12 12 12 14 15 15 16 17 17 18 18 18 19 19 20 22 23 23 25 3 3. 1 3. 2 3. 3 3. 4 3. 5 3. 6 3. 7 3. 8 3. 9 3. 10 3. 11 PROGRAMMING Entering programming mode Selecting a menu Viewing menu selections Accept programming changes If you make a mistake while programming Exiting a menu Exit programming mode Time windows (menu 0) Access menu (menu 1) Holidays menu (menu 2) DST dates (menu 3) 27 27 27 27 27 27 28 28 28 29 30 31 4 4. 1 4. 2 4. 3 IN CASE OF TROUBLE What happens when an alarm occurs In case of accidental activation Evacuation planning 32 32 32 32 5 5. 1 5. 2 5. 3 APPENDIX Sample installations LCD display messages System data 34 34 35 36 Section 1: System Overview Introduction The Regency Model 4734 Access Expander is an add-on device to the 4720 security system, designed especially for businesses needing to control access for a large number of users. The 4734 enables you to easily control a large facility with access for 1, 000 users and provides your business with dependable, 24-hour protection. The 4734 system has been custom programmed and installed using the components, options, and features that most closely meet your needs. Because the installation is managed by your local security company, your system may include some features not covered in this manual or may lack some features that are discussed. [. . . ] The options that are relevant to arming/disarming are described below. See section 3. 4 for complete descriptions of how the arm menu works and the options available through it. (Use the TEST key to move to the next area. ) To arm all areas you have access to and return to the normal operating display, press 2 . To disarm all areas that you have access to and return to the normal operating display, press 0 . This also resets alarms for all areas in alarm. Bypassing a Zone In some cases you may want to temporarily bypass, that is, turn off protection, on a particular zone. If your system is programmed to require an access code, the LCD will display the number of the zone you are attempting to bypass and will prompt you to enter the access code. If, for example, you are attempting to bypass zone 5, the touchpad will display "5-ENTER CODE. " If you were successful, the touchpad will display "BYPASSED. " If the touchpad displays "RESTRICTED ZONE, " you have attempted to bypass a fire or panic zone. The numbers and locations of zones that have been bypassed will display. If the system is armed when you attempt to find out which zones have been bypassed, you must enter your access code. In this case, after you press BYPS , the touchpad will display "ENTER CODE. " 4. 5. 6. 22 Unbypassing a Zone Unbypassing a zone makes it ready once again to detect alarms. Press BYPS . If the touchpad displays "RESTRICTED ZONE, " you have attempted to unbypass a fire or panic zone or a not ready zone with an armed system. Fire and panic zones cannot be bypassed (so there is no need to unbypass them). Not ready zones cannot be unbypassed if doing so would cause an alarm. Bypassing/Unbypassing Doors To latch doors open or to unlatch doors that have been latched open, follow these steps. (If the doorstation you want to latch/unlatch is the one you're currently using, you don't need to enter the ID number. ) Press DOOR BYPS . 3. 23 Viewing System Information STAT lets you find out which zones are not ready to be armed. If your LCD indicates "NOT READY" or "TROUBLE" when you attempt to arm the system, press STAT to see the affected zones. If you're using the area menu, STAT gives the status of the area you are currently attempting to arm. To see additional areas to which you have access, press TEST to skip to the areas you wish to view, then press STAT . STAT , in combination with other keys, allows you to view other system information. 1 STAT displays all the zone numbers and names in the areas controlled by the touchpad you are currently using. 2 STAT displays the number and location of the touchpad you are currently using. 4 STAT displays the installed version of the 4734 software. Resetting an Alarm To reset an alarm in a single-area system, enter your access code. The alarm will stop sounding and the system will disarm. Silencing (Muting) a Trouble Condition To silence a trouble condition alert tone, press MUTE MUTE . [. . . ] It is a good idea to keep a flashlight in a designated place in each room for emergencies. Make sure all family members or workers realize that personal belongings can be replaced, but people can't. Under no condition should anyone return after escaping from a burning building. A good evacuation plan should specify a certain meeting place outside of the building so that all evacuees can be accounted for and given medical treatment if necessary. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SILENT KNIGHT REGENCY 4724C-ZONE EXPANDER




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SILENT KNIGHT REGENCY 4724C-ZONE EXPANDER will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.