User manual SILENT KNIGHT 5496

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SILENT KNIGHT 5496. We hope that this SILENT KNIGHT 5496 user guide will be useful to you.


SILENT KNIGHT 5496 : Download the complete user guide (760 Ko)

Manual abstract: user guide SILENT KNIGHT 5496

Detailed instructions for use are in the User's Guide.

[. . . ] MODEL 5496 Intelligent Power Module Installation and Operations Manual Document 151276 08/12/10 Rev: E1 P/N 151276:E1 ECN: 10-484 Contents Section 1 Overview 1. 1 1. 2 1. 3 1. 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 5496 Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Agency Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Add up the current draw for all auxiliary devices and record in the table at Line B. 2. Add up all notification appliance loads and record in the table at Line C. For notification appliances and auxiliary devices not mentioned in the manual, refer to the device manual for the current ratings. Make sure that the total alarm current you calculated, including current for the panel itself, does not exceed 6. 0 A. Complete the remaining instructions in Table 2-4 to determine battery size requirements. 2. 6. 1. 1 Maximum Battery Standby Load Table 2-3 shows the maximum battery standby load for the 5496 based on 24 and 60 hours of standby. The standby load calculations of line J in the Current Draw Calculation Worksheet (Table 2-4) must be less than the number shown in Table 2-3 for the battery size used and standby hours required. Table 2-3: Maximum Battery Standby Load Rechargeable Battery Size 7 AH 12 AH 18 AH 35 AH Max. Alarm 270 mA 475 mA 685 mA 1370 mA 105 mA 190 mA 270 mA 540 mA * Required for NFPA 72 Auxiliary Protected Fire Alarm systems for Fire Alarm Service (City Box) and Remote Station Protected Fire Alarm systems (Polarity Reversal) and Digital Alarm Communicator/ Transmitter (DACT). Note: 33 max battery size for FM (Factory Mutual) installations 2-4 151276 Before You Begin Installing 2. 6. 2 Current Draw Worksheet For each 5496 in the installation, use this worksheet to determine current requirements during alarm/battery standby operation. Silent Knight Addressable FACP Installation Manuals can be found on Silent Knight's web site at www. silentknight. com. 3. 1 AC Power At installation, connect the AC terminals to 120 VAC source as shown in Figure 3-1. It may be necessary for a professional electrician to make this connection. The AC terminals are rated as 120 VAC, 50 or 60 Hz, 2. 5 A. To 120 VAC Power Source To AC Supervised Non-power limited Figure 3-1 AC Power Connection 151276 3-1 Model 5496 Intelligent Power Module Installation and Operation Manual 3. 2 Battery Connection The 5496 battery charge capacity is 7. 0 AH not to exceed 35. 0 AH. Determine the correct AH rating per your current load calculation (see Table 2-4). Note: If you require the power of back up batteries that are too large for the 5496, you can use the RBB cabinet. (Refer to P/N 151306 for RBB installation instructions. Wire batteries in series to produce a 24-volt equivalent. Do not parallel batteries to increase the AH rating. To Panel Red Black Battery Jumper (P/N 140694) Shipped With 5496 Supervised Non-Power Limited UL Listed 12V Battery Gell Cell UL Listed 12V Battery Gell Cell Replace batteries every 5 years. Figure 3-2 Battery Connection 3-2 151276 Hardware Installation 3. 3 Connecting the 5496 to the FACP 1. (See Section 3. 3. 1) Figure 2-1 shows the location of the dipswitches on the 5496 board. Configure the 5496 module by adding it to the system (through JumpStart or manually). These procedures are described in Silent Knight addressable FACP Installation Manuals. Silent Knight Addressable FACP Installation Manuals can be found on Silent Knight's web site at www. silentknight. com. 5496 Board Supervised Power Limited 5820XL (Main SBUS) Figure 3-3 Class B 5496 Connection to FACP 151276 3-3 Model 5496 Intelligent Power Module Installation and Operation Manual 3. 3. 1 Setting the Device ID All SBUS modules in the system must have a unique number (1-31) to identify them to the FACP. Figure 3-4 shows dipswitch setting and the corresponding module ID numbers. Figure 3-4 Possible Module Addresses 3-4 151276 Hardware Installation 3. 4 Notification Appliance Wiring Note: Not all devices can use the Sync feature. Be sure to check Table A-1 in Appendix A to ensure the device you have chosen will work with this feature. 3. 4. 1 Class A Supervised Wiring Figure 3-5 shows how to wire for Class A output supervision. Refer to Section 4 for notification appliances compatible with the 5496. Class A Output Notification Circuits The configuration shown in Figure 3-5 shows two, 3-amp devices wired as Class A circuits. When you are using the outputs as Class A circuits, loop the wiring back to the corresponding circuit pair. [. . . ] After product is processed, Silent Knight will pay for shipping product back to customer via UPS ground. Products that are returned in cabinets will be charged an additional $50 to cover the extra shipping and handling costs over board only returns. Silent Knight has the authority to determine if a product is repairable. Products that are deemed un-repairable will be returned to the customer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SILENT KNIGHT 5496




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SILENT KNIGHT 5496 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.