User manual SILENT KNIGHT 5083I

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SILENT KNIGHT 5083I. We hope that this SILENT KNIGHT 5083I user guide will be useful to you.


SILENT KNIGHT 5083I : Download the complete user guide (1729 Ko)

Manual abstract: user guide SILENT KNIGHT 5083I

Detailed instructions for use are in the User's Guide.

[. . . ] SILENT KNIGHT 5000 Series Entry System Installation and Operation Manual Part Number 151174D, 01/03 Content Section 1 Overview 1. 1 1. 2 1. 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 User Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 What's In the Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 About this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Install a reverse bias diode (1N5401 supplied with the 5083 and 5084 panels) across the DC doorstrike coil to suppress arcing and electrical noise. (See Figure 3-10. ) Caution: The maximum allowable current to operate a DC doorstrike is 1A. Damage to the power supply and to the battery charging circuit will occur if this is exceeded. 3-16 151174 Installation Instructions 3. 5. 9 Installing an AC Doorstrike 1. Install the electric doorstrike in the door frame according to the manufacturer's specifications. Figure 3-11 AC Doorstrike Wiring Diagram 2. Wire a transformer (24 VAC maximum) in series with the door strike opener, to terminals 4 and 5. (See Figure 3-11. ) Note: Do Not use the transformer that powers the 5083 or 5084 control panel. The maximum voltage rating of the door strikes contacts is 250VAC @ 1A. Do Not install a reverse bias diode across the coil. 3. 5. 10 Doorstrike Reset Switch In installation sites requiring a magnetic contact to re-lock a door prior to the expiration of the programmed time ("DOOR TIME"--see section 4. 2. 1 step 22) use the following steps. The contact must be in the open state when the magnet is next to it. 151174 3-17 Series 5000 Entry System Installation/Operation Manual 3. 5. 11 Installing Phone Lines The 5000 Series Entry System requires a RJ11X or RJ11W telephone jack to be installed by the phone company. Wire the phone lines to 5083 or 5084 control panel terminals 15 and 16. (See Figure 3-12. ) Figure 3-12 Telephone Wiring Diagram 3. 5. 11. 1 Using Ground Start If the phone system at the installation site is a ground start system, the auxiliary relay must be programmed for Ground Start (See 4. 2. 1 step 28 for instruction on Auxiliary relay programming). See Figure 3-13. Figure 3-13 Ground Start Telephone Wiring Diagram 3-18 151174 Installation Instructions 3. 5. 12 Installing a Mail Carrier Lock panel. Note: The "mail carrier lock" is optional and is supplied by the Post Office. 1. (See Figure 3-14. ) Model 5084 Mail Carrier Lock Hole Plug Model 5083 Figure 3-14 Mail Carrier Lock Hole Plug Location 2. Use the the #8-32 nuts and lock washers (both supplied) to secure the mail carrier lock (see Figure 3-15). Figure 3-15 Inside view of 5083/5084 Control Panel 151174 3-19 Series 5000 Entry System Installation/Operation Manual 3. Adjust the push-button switch so that the button is completely out when the mail carrier key is turned in the lock. Note: If the mail carrier lock is not used, do not remove the red cap from the mail carrier button. 3. 5. 13 Installing a Sonalert/Piezo to the Alarm Output In installation sites requiring an alarm output when the door access codes are tampered with, a sonalert/piezo (12 VDC, 100 mA maximum) can be installed. (See Figure 3-16. ) Figure 3-16 Sonalert/Piezo to 5083/5084 Control Panel Wiring Diagram 2. Set the auxiliary relay to the "ALARM" selection in "System Options" in programming. (See Section 4. 2. 1 step 28. ) Note: 5083 and 5084 installations using a secondary touch-tone relay or a ground start telephone system CANNOT use the alarm output. 3-20 151174 Installation Instructions 3. 6 Model 5076 Heater Kit The Model 5076 Heater Kit can be used with the Model 5083/5084 Control Panel. It is designed to maintain the temperature inside the cabinet above 32° F when the outside temperature is -20° F. The heater uses a self-regulating positive temperature coefficient (PTC) material for the heating element. The heater bracket is electrically insulated from the heater element. 3. 6. 1 To Install the 5076 Heater 1. (See Figure 3-17. ) Figure 3-17 Keypad Circuit Board Retaining Nuts 2. [. . . ] The attendant can hang up the phone by pressing the * button. 6-2 151174 Section 7 Programming information record This section is used to record and store the programmed system options and the user information. Table 7. 1 System Options Record Table 7-1: System Options Record Use the following Table 7-1 to record the programmed System Options. Programming Option ACCESS CODE ROTARY DIALING ?* BEFORE 6 PBX ACCESS # USER # LENGTH CALL LENGTH DOOR TIME AUX TIME SYSTEM MESSAGE SPEAKER VOLUME AUX RELAY AUX TIME WINDOW Your Selection Notes 151174 7-1 Series 5000 Entry System Installation/Operation Manual 7. 2 User Information Record Table 7-2 has spaces for ten user's information, make as many copies of this table as necessary to record all system user information. Table 7-2: User Information Record User Name Programmable Options USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS Selection Notes 7-2 151174 Programming information record Table 7-2: User Information Record User Name Programmable Options USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS USER NUMBER USER PHONE USER CODE DIAL PBX DOOR ACCESS AUX ACCESS Selection Notes 151174 7-3 Series 5000 Entry System Installation/Operation Manual 7-4 151174 Silent Knight Fire Product Warranty and Return Policy General Terms and Conditions · All new fire products manufactured by Silent Knight have a limited warranty period of 18 months from the date of manufacture against defects in materials and workmanship. · This limited warranty does not apply to those products that are damaged due to misuse, abuse, negligence, exposer to adverse environmental conditions, or have been modified in any manner whatsoever. Repair and RA Procedure · All products that are returned to Silent Knight for credit or repair require a RA (Return Authorization) number. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SILENT KNIGHT 5083I




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SILENT KNIGHT 5083I will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.