User manual SAMSUNG ND112HHXEB

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual SAMSUNG ND112HHXEB. We hope that this SAMSUNG ND112HHXEB user guide will be useful to you.


SAMSUNG ND112HHXEB : Download the complete user guide (3489 Ko)

Manual abstract: user guide SAMSUNG ND112HHXEB

Detailed instructions for use are in the User's Guide.

[. . . ] _IB_E 32725-2. 10. 10. 06. indd 1 2011-1-22 14:39:50 Features of your new air conditioner · Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest. This summer, beat the heat with your own air conditioner. · Cost Efficient System Your new air conditioner not only provides maximum cooling power in the summer, but can also be an efficient heating method in the winter with the advanced "Heat pump" system. This technology is up to 300% more efficient than electrical heating, so you can further reduce its running cost. [. . . ] In order to prevent electric shocks, fires or injuries, always stop the unit, disable the protection switch and contact SAMSUNG's technical support if the unit produces smoke, if the power cable is hot or damaged or if the unit is very noisy. Always remember to inspect the unit, electric connections, refrigerant tubes and protections regularly. The unit contains moving parts, which should always be kept out of the reach of children. If performed by unauthorized personnel, these operations may cause electric shocks or fires. All the materials used for the manufacture and packaging of the air conditioner are recyclable. The packing material and exhaust batteries of the remote control(optional) must be disposed of in accordance with current laws. The air conditioner contains a refrigerant that has to be disposed of as special waste. At the end of its life cycle, the air conditioner must be disposed of in authorized centers or returned to the retailer so that it can be disposed of correctly and safely. installinG the unit IMPORTANT:When installing the unit, always remember to connect first the refrigerant tubes, then the electrical lines. Upon receipt, inspect the product to verify that it has not been damaged during transport. If the product appears damaged, DO NOT INSTALL it and immediately report the damage to the carrier or retailer (if the installer or the authorized technician has collected the material from the retailer. ) After completing the installation, always carry out a functional test and provide the instructions on how to operate the air conditioner to the user. Do not use the air conditioner in environments with hazardous substances or close to equipment that release free flames to avoid the occurrence of fires, explosions or injuries. The air conditioner should be used only for the applications for which it has been designed: the indoor unit is not suitable to be installed in areas used for laundry. 14 Duct_AVXDS_IB_E 32725-2. 10. 10. 06. indd 14 2011-1-22 14:40:09 Our units must be installed in compliance with the spaces indicated in the installation manual to ensure either accessibility from both sides or ability to perform routine maintenance and repairs. The units' components must be accessible and that can be disassembled in conditions of complete safety either for people or things. For this reason, where it is not observed as indicated into the Installation Manual, the cost necessary to reach and repair the unit (in safety, as required by current regulations in force) with slings, trucks, scaffolding or any other means of elevation won't be considered in-warranty and charged to end user. Power suPPly line, fuse or circuit breaker Always make sure that the power supply is compliant with current safety standards. Always install the air conditioner in compliance with current local safety standards. Verify that the voltage and frequency of the power supply comply with the specifications and that the installed power is sufficient to ensure the operation of any other domestic appliance connected to the same electric lines. Always verify that the cut-off and protection switches are suitably dimensioned. Verify that the air conditioner is connected to the power supply in accordance with the instructions provided in the wiring diagram included in the manual. Always verify that electric connections (cable entry, section of leads, protections. . . ) are compliant with the electric specifications and with the instructions provided in the wiring scheme. Always verify that all connections comply with the standards applicable to the installation of air conditioners. Make sure that you earth the cables. - Do not connect the earth wire to the gas pipe, water pipe, lighting rod or telephone wire. [. . . ] Check the indoor unit address on the plan that you are to install and set the address according to the plan. Note You may not need to set main address if you selected Auto Address Setting from the outdoor unit: see details on the outdoor unit installation manual. WhenMAINaddressissetas"12". For Example Setting RMC Address The SW03, SW04 RMC switch is the address setting switch for controlling the indoor unit with the centralized controller. You must set the SW03, SW04 and K2 switch when using the centralized controller. For Example WhenRMCaddressissetas"12". SW03 SW04 32 Duct_AVXDS_IB_E 32725-2. 10. 10. 06. indd 32 2011-1-22 14:40:26 Additional functions No. K1 Function External room sensor Centralized controller Drain Pump ON Not use Not use Not use OFF Use Use Use K1 K2 K3 K4 SW05 K2 K3 K4 K1 OFF Heating mode : Setting temperature compensation value = 0°C Thermo OFF Fan OFF SW05 No. K5 Function Heating Current Temperature Compensation Filter Time Hot Water Heater - ON +2°C 1, 000 hours Not use - OFF +5°C 2, 000 hours Use - K5 K6 K7 K8 SW06 K6 K7 K8 SW06 No. K9 Function Indoor Expansion Valve For Heating Stop Wired Remocon Group Master External Control External Control Output ON Fix 80 step Not use Not use OFF 0 or 80 step Use Use K9 K10 K11 K12 SW07 K10 K11 K12 Thermal ON Operation ON SW07 33 Duct_AVXDS [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE SAMSUNG ND112HHXEB




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual SAMSUNG ND112HHXEB will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.