User manual RUSSOUND CA64

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RUSSOUND CA64. We hope that this RUSSOUND CA64 user guide will be useful to you.


RUSSOUND CA64 : Download the complete user guide (662 Ko)

Manual abstract: user guide RUSSOUND CA64

Detailed instructions for use are in the User's Guide.

[. . . ] 4-Source Multi-Zone Central Audio Controller/Amplifiers CAi-Series Instruction Manual ROCK JAZZ R&B CHILDRENS VOLUME · ON / OFF · VOLUME · SOURCE SOURCE STORE REMOTE SENSOR POWER REMOTE SENSOR CA-KP2 CA-LCD2 CA 6. 4i 6-Zone, 4-Source Central Controller/Amplifier CA6. 4i 6 Zone -- 4 Source Central Controller/ Amplifier 1 2 3 4 5 6 POWER ZONE CA 4. 4i 4-Zone, 4-Source Central Controller/Amplifier CA4. 4i 4 Zone -- 4 Source Central Controller/ Amplifier 1 2 3 4 POWER ZONE Patented IMPORTANT SAFEGUARDS 12. Power - Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, receptacles, and the point where they exit from the appliance. Cleaning - The appliance should be cleaned only as recommended by the manufacturer. Non-use Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time. [. . . ] · On List 4 (opposite) copy down the room name to the zone number from List 3 on pg 6. NOTE: the keypad and the speakers in each room must be hooked to the corresponding numbered zone. Zone 1 _________________ Zone 2 _________________ Zone 3 _________________ Zone 4 _________________ WIRING AT THE CONTROLLER CAi System keypads are wired with CAT-5 wire. Due to the qualities of CAT-5 wire, when using it for keypad control wire with the CAi-Series, it is recommended to use the following color code for maximum performance. CAT-5 Brown/White Brown Green Orange/White Orange Green/White Blue/White Blue Type Ground IR Signal 12VDC+ Source Select Source Select Channel Select Volume Balance CLEAN INSTALLATIONS For clean installations, we recommend using RJ-45 jumpers to run from the CAi controller to an RJ-45 Wall Plate then running your keypads from the Wall Plate. Figure 10 ­ Connections with RJ-45 Wall Plate GND +12V CH SEL SEL3 Figure 9 ­ Connections with CAT-5 wire KEYPAD PORTS 1 2 3 4 12345678 RJ-45 using T568A Wiring Standard ORANGE ORANGE BROWN GREEN BLUE SEL1 VOL IR BAL CAT-5 Cable KEYPAD PORTS 1 2 3 4 8 INSTALLING KEYPADS PUNCHDOWN TERMINALS Figure 11 ­ Punchdown Terminal on CAi keypad INSTALLING THE KEYPADS · The best infrared remote performance is achieved with the keypad away from any direct sunlight. · Choose a place that is easily seen from the position where a person is most likely to be located. · Check whether or not you can route the wire to the location you have chosen. 18 cubic inches) or p-rings and cut in the boxes using a key-hole saw or sheetrock knife/hand saw. · If you are installing the optional DSC keypad you will need to use a double-gang electrical box. If you are installing both the optional DSC and DAN keypad you will need to install a triple-gang electrical box. · If you feel uncomfortable cutting into your walls and running wire through the walls, seek help from a professional installer or an electrician. · If using 22 AWG wire, connect each wire to the correct position 1 thru 8 using the included punchdown tool. · If using CAT-5 wire, connect each wire to its corresponding color labeled on the punchdown terminal. · Mount the keypad in the junction box and attach the Decora© plate. Insert the label in the keypad keeping the input number in sequence with the source selected. · Repeat the above steps until all keypads are installed. The CAi Keypads come with 110 punchdown terminals. These terminals are quick, easy to install and provide a strong connection. Press wires into punchdown terminal with punchdown tool as shown in Figure 12. Figure 12 ­ Punching Down Wires Punchdown Tool CH SEL SEL3 SEL1 +12V GND BAL VOL IR Connector on CA-KP2 or CA-LCD2 BROWN GREEN ORANGE BLUE CAT-5 or 8-conductor 22 AWG wire 9 INSTALLING KEYPADS SETTING THE KEYPADS Before a keypad is installed into the j-box, turn on the power so that you can operate the keypad. CA-LCD2 Only: The amber and the green backlight brightness can be individually set. Press and hold the lamp button on the front of the keypad until the backlight switches to the other color. [. . . ] 4) If incorrect connections were found, correct the wiring and reconnect the keypads to the controller. After the controller has been powered off for at least 15 seconds, turn on the power switch of the CAi-Series controller. 5) If the problem persists, repeat steps above trying each keypad consecutively. 6) Inadequate ventilation can allow normal heat to build up and trip the protection circuit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RUSSOUND CA64




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RUSSOUND CA64 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.