User manual RUSSOUND CA

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual RUSSOUND CA. We hope that this RUSSOUND CA user guide will be useful to you.


RUSSOUND CA : Download the complete user guide (902 Ko)

Manual abstract: user guide RUSSOUND CA

Detailed instructions for use are in the User's Guide.

[. . . ] 4-Source Multi-Zone Central Audio Controller/Amplifiers CA-Series Instruction Manual ROCK JAZZ R&B CHILDRENS VOLUME · ON / OFF · VOLUME · SOURCE SOURCE STORE REMOTE SENSOR POWER REMOTE SENSOR CA-KP. 2 CA-LCD CA 6. 4 6-Zone, 4-Source Central Controller/Amplifier 6 ZONE -- 4 SOURCE CENTRAL CONTROLLER / AMPLIFIER ON 1 2 3 4 5 6 OFF POWER ZONE CA 6. 4 CA 4. 4pi 4-Zone, 4-Source Central Controller/Amplifier 4 ZONE -- 4 SOURCE CENTRAL CONTROLLER / AMPLIFIER ON 1 2 3 4 OFF POWER ZONE CA 4. 4pi IMPORTANT SAFEGUARDS 12. Power - Cord Protection - Power supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to cords at plugs, receptacles, and the point where they exit from the appliance. Cleaning - The appliance should be cleaned only as recommended by the manufacturer. Non-use Periods - The power cord of the appliance should be unplugged from the outlet when left unused for a long period of time. [. . . ] · Remove the connector and strip 1/8" off each end of the wire insulation. Zone 1 _________________ Zone 2 _________________ Zone 3 _________________ Zone 4 _________________ WIRING RUNS UP TO 100 FEET For wiring runs of up to 100 feet in length, we recommend the use of CAT-5 wire. Due to the qualities of CAT-5 wire, when using it for keypad control wire with the CA-Series, it is recommended to use the following color code for maximum performance. CAT-5 Number Brown/White 1 Brown 2 Green 3 Orange/White 4 Orange 5 Green/White 6 Blue/White 7 Blue 8 Type Ground IR Signal 12VDC+ Source Select Source Select Channel Select Volume Balance WIRING RUNS FROM 100-200 FEET For wiring runs exceeding 100 feet and extending up to 200 feet, we recommend the use of 8-conductor 22 AWG stranded wire such as Russound MCW2418. If using 22 AWG wire, the order in which you wire is not important as long as you wire in the same order at both the CA unit as well as the keypad. Use List 5 (below) to write down the wire you use for each pin number. NOTE: Wiring runs longer than 200 feet are not recommended for the CA-Series Keypads. Pin 1 _______________ Pin 2 _______________ Pin 3 _______________ Pin 4 _______________ Pin 5 _______________ Pin 6 _______________ Pin 7 _______________ Pin 8 _______________ Figure 10 ­ Connections with 22AWG wire Figure 9 ­ Connections with CAT-5 wire INPUT FROM KEYPADS 4 3 INPUT FROM KEYPADS 12345678 12345678 4 3 BROWN GREEN ORANGE BLUE CAT-5 WIRE 12345678 12345678 8 CONDUCTOR 22AWG STRANDED WIRE 8 INSTALLING KEYPADS PUNCHDOWN TERMINALS Figure 11 ­ Punchdown Terminal on CA-KP. 2 and CA-LCD INSTALLING THE KEYPADS · The best infrared remote performance is achieved with the keypad away from any direct sunlight. · Choose a place that is easily seen from the position where a person is most likely to be located. · Check whether or not you can route the wire to the location you have chosen. 20 cubic inches) or p-rings and cut in the boxes using a key-hole saw or sheetrock knife/hand saw. · If you are installing the optional DSC keypad you will need to use a double-gang electrical box. If you are installing the CA-LCD, DSC and the optional DAN keypad you will need to install a triple-gang electrical box. · If you feel uncomfortable cutting into your walls and running wire through the walls, seek help from a professional installer or an electrician. · If using 22 AWG wire, connect each wire to the correct position 1 thru 8 using the included punchdown tool. · If using CAT-5 wire, connect each wire to its corresponding color labeled on the punchdown terminal. · Mount the keypad in the junction box and attach the Decora plate. Insert the label in the keypad keeping the input number in sequence with the source selected. · Repeat the above steps until all keypads are installed. 2 1 3 6 5 4 8 7 CH SEL +12V GND SEL3 SEL1 BAL IR The CA-KP. 2 and CA-LCD come with 110 punchdown terminals. These terminals are quick, easy to install and provide a strong connection. Press wires into punchdown terminal with punchdown tool as shown in Figure 12. Figure 12 ­ Punching Down Wires 87 54 36 21 CH SEL +12V SEL3 SEL1 BAL VOL Punchdown Tool GND IR CH SEL SEL3 SEL1 +12V GND BAL 2 1 3 6 5 4 8 VOL IR 7 Connector on CA-KP. 2 or CA-LCD ORANGE BROWN GREEN BLUE CAT-5 or 8-conductor 22 AWG wire VOL 9 INSTALLING KEYPADS SETTING THE KEYPADS Before a keypad is installed into the j-box, turn on the power so that you can operate the keypad. [. . . ] This circuit will stabilize the balance line input and keep it centered. They can be used to free up one of the 8 required conductors if one is open, shorted or if an extra conductor is needed for a secondary IR receiver's signal in that zone. Position #1 is GND, #3 is 12VDC, #8 is Balance. CA Keypad Connector @ Rear of Processor 820 Ohm 1/4w 3. 9K Ohm 1/4w 1 2 3 4 5 6 7 8 GND +12VDC Balance TROUBLESHOOTING COMBINING ADDITIONAL IR RECEIVERS When combining a CA Series multi-source controller and a secondary IR system together, it needs to be done after the CA System. This signal is demodulated at the keypad and is re-modulated at the processor then sent to the emitter out-puts. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE RUSSOUND CA




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual RUSSOUND CA will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.