User manual ROSIERES VE 22

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROSIERES VE 22. We hope that this ROSIERES VE 22 user guide will be useful to you.


ROSIERES VE 22 : Download the complete user guide (1181 Ko)

Manual abstract: user guide ROSIERES VE 22

Detailed instructions for use are in the User's Guide.

[. . . ] Choose the discharge outlet to use: Only filtering version: use ONLY the upper B1 outlet (Fig. Check that this, once installation is completed, is not obstructed and that there is sufficient space so that the purified fumes and steam can return easily into the kitchen. Check that the lateral wall units between which to install the hood are sufficiently robust for installing the hood. Otherwise mount the hooking brackets on the wall (*) to use as additional supports: a. [. . . ] Note: the position of the brackets can be adjusted during installation, suitably loosening and retightening the screws that fix them to the hood. The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If provided with a plug connect the hood to a socket in compliance with current regulations and positioned in an accessible area. If it not fitted with a plug (direct mains connection) or if the plug is not located in an accessible area apply a bi-polar switch in accordance with standards which assures the complete disconnection of the mains under conditions relating to overcurrent category III, in accordance with installation instructions. Put perforation diagram N3 on the REAR of aesthetic panel J (the arrow on the diagram turned upward towards the UPPER EDGE of the aesthetic panel). Put the steam collector over the aesthetic panel and fix it with 8 screws L. Remount the door on the hood, first on upper guides M1, then on the lower M2. Close completely and re-open the door to check its correct sliding on the guides. 11 In some products an electrically or mechanically activated valve is envisaged instead of an aspiration motor. This is usually installed on discharge outlet B1 and fixed to the caisson of the hood with 3 screws, while a stopper is installed in outlet B2, fixed in its turn with 1 screw. If you want to install the valve on outlet B2, dismantle the valve from the caisson, remove the fixing screws, and install it in place of the stopper, the latter to be fixed on the cover of outlet B1. In any case it is necessary to replace the cartridge at least every four mounths (or when the filter saturation indication system ­ if envisaged on the model in possession ­ indicates this necessity). Cover the grill that protects the suction motor with the carbon filter so that the slots on the filter correspond to the pins on the Turn the carbon filter clockwise to block them (bayonet fixing). If the lights do not work, make sure that the lamps are fitted properly into their housings before you call for technical assistance. We decline any responsibility for any problems, damage or fires caused to the appliance as the result of the nonobservance of the instructions included in this manual. This appliance is marked according to the European directive 2002/96/EC on Waste Electrical and Electronic Equipment (WEEE). By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. Do not connect the appliance to the mains until the installation is fully complete. Before any cleaning or maintenance operation, disconnect the hood from the mains by removing the plug or disconnecting the home mains switch. The appliance is not intended for use by children or persons with impaired physical, sensorial or mental faculties, or if lacking in experience or know-how, unless they are under supervision or have been trained in the use of the appliance by a person responsible for their safety. Children should be monitored to ensure that they do not play with the appliance. The hood must NEVER be used as a support surface unless specifically indicated. [. . . ] The premises must be sufficiently ventilated, when the kitchen hood is used together with other gas combustion devices or other fuels. The suctioned air must not be conveyed into a conduit used for the disposal of the fumes generated by appliances that combust gases or other fuels. The use of exposed flames is detrimental to the filters and may cause a fire risk, and must therefore be avoided in all circumstances. Any frying must be done with care in order to make sure that the oil does not overheat and burst into flames. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROSIERES VE 22




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROSIERES VE 22 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.