User manual ROSIERES V 39

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROSIERES V 39. We hope that this ROSIERES V 39 user guide will be useful to you.


ROSIERES V 39 : Download the complete user guide (1827 Ko)

Manual abstract: user guide ROSIERES V 39

Detailed instructions for use are in the User's Guide.

[. . . ] When frying, take particular care to prevent oil and grease from catching fire. To avoid possible risks of fire always comply with the indicated instructions when cleaning anti-grease filters and when removing grease deposits from the appliance. The appliance can be used in both the filtering and ducting version. 1), the air and va-pours conveyed by the appliance are depurated by charcoal filter and recirculated around the room. [. . . ] 2), cooking vapours and odours are conveyed straight outside by a disposal duct which passes through the wall/ceiling. Fix the air venting flange onto the apparatus; it must be fixed either by means of two screws (Fig. Particular care must be paid to the grease filters which must be periodically cleaned in relation to use (at least once every two months). Remove the grease filters and wash them either by hand or in the dishwasher using neutral detergent. To take off the anti-grease filters: at the handle, push the stop inwards and pull the filter downwards (Fig. Any fat deposits should be removed from the appliance periodically depending on amount of use (at least every 2 months). To clean painted appliances on the outside, use a cloth dipped in lukewarm water and neutral detergent. To clean steel, copper or brass appliances on the outside, it is always best to use specific products, Before assembling, in order to manoeuvre the appliance more easily, take off the grease filters: at the handle, push the stop inwards and pull the filter downwards (Fig. IMPORTANT: So as not to damage your product, during installation USE ONLY THE SCREWS PROVIDED. To compensate possible depth voids between the appliance and the wall, a plastic SPACING BAR to be fixed at the back of the appliance by means of the three screws A is included (Fig. Comply with the official instructions provided by the competent authorities in merit when installing the disposal duct. In addition, exhaust air should not be discharged into a wall cavity, unless the cavity is designed for that purpose. The room must be well aerated in case a hood and some other heat equipment fed with an energy other than electricity (gas, oil, coal heaters, etc) operate at the same time. In fact the intake hood, disposing of air, could create a vacuum in the room. This prevents the gas exhausted by the heat source from being intaken again. It is therefore advisable to ensure the room contains air taps able to ensure a steady flow of fresh air. Check the data label inside the appliance; if the symbol ( ) is printed, read the following: this appliance has such technical particulars that it belongs to class II insulation, therefore it must not be earthed. The following warning is valid in the United Kingdom only: in case your cable is not furnished with a plug, read the following instructions; as the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: ­ the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black; ­ the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. Check the data label inside the appliance; if the symbol ) is NOT printed, read the following: ATTENTION: ( This appliance must be earthed. When making the electrical connections, check that the current socket has a ground connection. [. . . ] The following warning is valid in the United Kingdom only: in case your cable is not furnished with a plug, read the following instructions; as the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows: ­ the wire which is coloured green and yellow must be connected to the terminal in the plug which is marked with the ], or coloured green or letter E or by the earth symbol [ green and yellow; ­ the wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black; ­ the wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red. When making the electrical connections, check that the voltage values correspond to those indicated on the data plate inside the appliance itself. In case your appliance is not furnished with a non separating flexible cable and has no plug, or has not got any other device ensuring omnipolar disconnection from the electricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the fixed installation. If your unit features a power lead and plug, position this so the plug is accessible. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROSIERES V 39




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROSIERES V 39 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.