User manual ROSIERES RDR 61 RUV

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROSIERES RDR 61 RUV. We hope that this ROSIERES RDR 61 RUV user guide will be useful to you.


ROSIERES RDR 61 RUV : Download the complete user guide (310 Ko)

Manual abstract: user guide ROSIERES RDR 61 RUV

Detailed instructions for use are in the User's Guide.

[. . . ] To avoid damage make exclusive use of the holes already prepared on the hood. Securing the telescopic flue: Basic installation requirements: – Set the electrical power supply within the space covered by the decorative flue. € If your unit is installed in an Exhaust hood, prepare the air exhaust hole. Place bracket (W) 50 mm from the ceiling and position this on the vertical of your hood, with the aid of the notches on the centre of the bracket (Fig. [. . . ] When the LED is green (flashing) it indicates that the TIMER has been activated with the key E. After 120h of operation, the LED L2 turns RED and flashes; It indicates that the grease filters need to be cleaned and the charcoal filters replaced. After cleaning the grease filters (and/or replacing the charcoal filters), restart the hour counter (RESET) by pressing the key E during display of the filter alarm. 14: Button A: turns the lights on/off; every 30 hours of operation the corresponding pilot lamp (S) comes on to indicate that the grease filters must be cleaned; every 120 hours of operation the corresponding pilot lamp (S) flashes to indicate that the grease filters must be cleaned and the charcoal filter replaced. To restart the hour counter (RESET), hold the button A pressed down for about 1” (while the pilot lamp S is on). Button B: drives the motor in first speed (the corresponding pilot lamp comes on); when holding it down for about 1”, the motor cuts out; when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Button C: drives the motor in second speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Button D: drives the motor in third speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Button E: drives the motor in fourth speed (the corresponding pilot lamp comes on); when pressing the button a second time (while the pilot lamp is on) , the TIMER is activated and thus the motor stops after 5’ (the pilot lamp flashes). Pay special attention to the grease filters; to remove the filter: push inward on the clamp at the handle and pull the filter downward. If the model purchased has the controls shown in Figure 13: see the paragraph “Controls shown in Fig. If the model purchased has the controls shown in Figure 11/12: the grease filter must be cleaned periodically: exactly how often depends on use (at least once every other month). If the model purchased has the controls shown in Figure 14: the grease filters must be cleaned approximately once every 30 hours of operation (when the light button lamp comes on) - Fig. Once the cleaned filters are reinstalled, to reset the counter hold the light button pressed down for about 1” (Fig. Charcoal filter/s: if using the hood in the filtering hood, the charcoal filter must be replaced periodically. To remove the charcoal filters, proceed as follows, depending on the model purchased: - if the hood features round charcoal filters (Fig. 10), remove the charcoal filter by first of all removing the two filter retainers M. If the model purchased has the controls shown in Figure 13, see the paragraph “Controls shown in Fig. If the model purchased has the controls shown in Figure 11/12, the charcoal filters must be replaced according to use: on the average once every 6 months. If the model purchased has the controls shown in Figure14, the charcoal filters must be replaced each time the light button (Fig. Lighting: - To gain access to the bulbs, remove the grease filters as described above and remove the bulbs. Replace only with CANDLE HALOGEN LAMP - Ø 35mm, E14–220-240 Vac, 28W or INCANDESCENT LAMP-E14–220-240 Vac, 40W - If the halogen lamps shown in Fig. [. . . ] Check the data label inside the appliance; if the symbol ( ) is NOT printed, read the following: ATTENTION: This appliance must be earthed. When making the electrical connections, check that the current socket has a ground connection. When making the electrical connections, check that the voltage values correspond to those indicated on the data plate inside the appliance itself. In case your appliance is not furnished with a non separating other device ensuring omnipolar disconnection from the electricity main, with a contact opening distance of at least 3 mm, such separating device ensuring disconnection from the main must be included in the and plug, position this so the plug is accessible. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROSIERES RDR 61 RUV




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROSIERES RDR 61 RUV will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.