User manual ROSIERES RBSI 94

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROSIERES RBSI 94. We hope that this ROSIERES RBSI 94 user guide will be useful to you.


ROSIERES RBSI 94 : Download the complete user guide (601 Ko)

Manual abstract: user guide ROSIERES RBSI 94

Detailed instructions for use are in the User's Guide.

[. . . ] - If the cable is damaged, replace it as soon as possible with another one which has the same characteristics and which is suitable for use at the power level of the appliance. A) Do not check the status of the filters while the cooker hood is operating B) Do not touch bulbs or adjacent areas, during or straight after prolonged use of the lighting installation. [. . . ] Drive in the fourth screw X and tighten the remaining 3 to allow definitive blocking of the upper part of structure B - Take the lower part of the telescopic structure C and insert it into the upper structure B (fig. - Suction version: fix the flexible pipe to the prepared air evacuation hole (fig 7). - Filtering version: fix the flexible pipe to the deflector M and fix screw I as indicated in (Fig. - Take the upper chimney piece and fix it to the structure using the 2 screws A (Fig. Join the lower chimney piece with the upper one and fix it carefully using adhesive tape L (Fig. Insert the suction unit inside the structure paying attention that the previously unscrewed screws O, hook into the slots in the lower part as indicated in (Fig. 11) - Remove adhesive tape L and rest the lower chimney piece above the cooker hood (Fig. -If the cooker hood is supplied with a lower chimney piece that must be fixed to the hood body with screws, remove the anti-grease filters from the hood by acting on the relevant handles (Fig. Then screw the lower chimney piece pipe to the inside of the hood, using screws P (Fig. Particles suspended in the air, therefore is subject to saturation (the time it takes for the filter to become saturated depends on the way in which the appliance is used). - To prevent potential fire hazards, the anti-grease filters should be washed a minimum of every 2 months (it is possible to use the dishwasher for this task). If the replacement and washing instructions are not followed, the anti-grease filters may present a fire hazard. The active carbon filters are used to purify the air which is released back into the room. The filters are not washable or re-usable and must be replaced at least once every four months. [. . . ] The anti-grease filter is used to trap any grease Alternates with the letter A (e. After the clean filter has been positioned correctly, the electronic memory must be reset by pressing button A for approximately 5 seconds, until the indication F or A shown on the display C stops flashing. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROSIERES RBSI 94




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROSIERES RBSI 94 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.