User manual ROBLIN VIZIO MURALE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN VIZIO MURALE. We hope that this ROBLIN VIZIO MURALE user guide will be useful to you.


ROBLIN VIZIO MURALE : Download the complete user guide (910 Ko)

Manual abstract: user guide ROBLIN VIZIO MURALE

Detailed instructions for use are in the User's Guide.

[. . . ] ⷠIf other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being fitted, if not larger. ⷠThe ducting system for this cooker hood must not be connected to any existing ventilation system, which is being used for any other purposes or to a mechanically controlled ventilation ducting. ⷠThe ducting used must be made from fire retardant materials and the correct diameter must be used, as incorrect sized ducting will affect the performance of this cooker hood. [. . . ] Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. 1 - item 7a & b) first by expanding the chimneys slightly to allow them to clamp around the bracket item 2 and secure the chimney stacks to the brackets using the two M4 screws item 12c provided. Fit the lower chimney sections by expanding the chimneys slightly to allow them from the top of the canopy to clamp around the upper chimney sections. Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws (Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. Insert the charcoal filter into the base of the motor housing and secure the filter with two metal securing straps item A as illustrated in Fig. 1 - item 7a & b) first by expand-ing the chimneys slightly to allow them to clamp around the bracket item 2 and secure the chimney stacks to the brackets using the two M4 screws item 12c provided. Fit the lower chimney sections by expanding the chimneys slightly to allow them from the top of the canopy to clamp around the upper chimney sections. To use the cooker hood in the recycling mode re-programme the hood as follows: Starting in the recycling mode (the contaminated air passes into the hood through the grease filters and the purifying activated charcoal filter and back out into the kitchen through grilles). Press the `+' button (while the motor and lights are switched `OFF') until the five LED lights will flash twice to indicate confirmation that the cooker hood is in the recycling mode. Press the `+' button (while the motor and lights are switched `OFF') until the five LED lights will flash once to indicate confirmation that the cooker hood is in the extraction mode. B - BASIC INSTRUCTIONS Lighting Press LED button 1 to switch `ON' the lights and the LED will illuminate to confirm the lights are switched `ON'. Motor Press LED button 2 to switch `ON' the fan motor (and adjust the speed of the fan motor by pressing the LED button `+' and `-`) and the LED lights 2, 3 and 4 will illuminate. The fan speed will be increased if constant pressure is kept on the (+) button. LED 2 : Minimum speed - cooking with one pan or simmering LED 2 & 3 : Medium speed - normal cooking with up to 4 pans LED 2, 3 & 4 : Maximum speed - frying and cooking foods with strong odours Press LED button 5 to obtain the boost position for maximum effect and the LED will illuminate to confirm fan is switched `ON'. c - COMPLEMENTARY INSTRUCTIONS · Boost speed : To obtain the best performance it is advisable to switch `ON' the cooker hood a few minutes (in the boost setting) before you start cooking. to program the complementary function , proceed as follows: - Press LED button 2 to switch `ON' the fan motor and adjust the speed of the fan by pressing the LED button `+' and `-`. You should keep applying pressure to the `+' and `-` button until the required speed is selected. It is advisable too that you should leave it running in the boost setting for approximately 5 minutes after finishing. [. . . ] Therefore, please have your receipt available when requesting service as this constitutes the date from which your guarantee commenced. This Guarantee does not cover : - Damage or calls resulting from transportation, improper use or neglect, the replacement of any light bulbs or filters or removable parts of glass or plastic. These items are considered to be consumable under the terms of this guarantee. This appliance complies with European regulations on low voltages Directive 2006/95/CE on electrical safety, and with the following European regulations: Directive 2004/108/CE on electromagnetic compatibility and Directive 93/68 on EC marking. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN VIZIO MURALE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN VIZIO MURALE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.