User manual ROBLIN VIZIO/3

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN VIZIO/3. We hope that this ROBLIN VIZIO/3 user guide will be useful to you.


ROBLIN VIZIO/3 : Download the complete user guide (1656 Ko)

Manual abstract: user guide ROBLIN VIZIO/3

Detailed instructions for use are in the User's Guide.

[. . . ] € To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles on the underside of the cooker hood and the cooker hood should be positioned away from doors and windows, which will create turbulence. € Ducting • If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type. € If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being fitted, if not larger. [. . . ] 650 mm when fitting above an electric hotplate and 700 mm when fitting above a gas hotplate. 5 & 6 and fix the metal diffuser to the frame of the chimney brackets using the height 5 x 10T hexagonal headed screws. A drawing on the drill gauge defines the positioning for the controls. € DUCTING The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible utilise rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Fit the non-return backflow flaps C over the round outlet item 6 on top of the canopy while pressing down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. 6c - item 7a) when installing the ducting version and secure the chimney stacks to the brackets using the M4 screws provided. Fit the recirculation spigot R onto the chimney bracket using the same fixing screws Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape (Fig. Make the electrical connection as described in the section titled ELECTRICAL. 6c - item 7a) when installing the recirculation version and secure the chimney stacks to the brackets using the M4 screws provided. Insert the charcoal filter into the base of the motor housing and secure the filter with two securing straps A as illustrated Fig. 8 GB 4 OPERATION A B C D Control panel E F G H Button A B C D Function Display Turns the suction motor on and off at the last Displays the speed set speed used. Activates intensive speed from any other speed even with the motor off. This speed is timed to run for 10 minutes, after which the system returns to the previous speed. Activates the motor at a speed that allows extraction of 100 m3/h for 10 minutes every hour, after which the motor stops. When the filter alarm is on, press the button for approximately 3 seconds to reset the alarm. E Displays 24 and the bottom right hand spot flashes, while the motor is turned on On completing the procedure the previous indicator is turned off: FF indicates that the metal grease filters need washing. [. . . ] If lamp failure has occurred then it should be replaced with identical replacement. Do not replace with any other type of lamp and do not fit a lamp with a higher rating. 7 GUARANTEE AND AFTER SALES SERVICE • In the event of any malfunction or anomaly, notify your fitter who will have to check the appli- 10 GB ance and its connection. The wires in this mains lead are coloured in accordance with the following code: Green & Yellow Earth ELECTRICAL CONNECTION Before connecting to the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate inside the cooker hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN VIZIO/3




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN VIZIO/3 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.