User manual ROBLIN VISTA 900 6056000 IX

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN VISTA 900 6056000 IX. We hope that this ROBLIN VISTA 900 6056000 IX user guide will be useful to you.


ROBLIN VISTA 900 6056000 IX : Download the complete user guide (1156 Ko)

Manual abstract: user guide ROBLIN VISTA 900 6056000 IX

Detailed instructions for use are in the User's Guide.

[. . . ] € To ensure the best results, the cooking fumes should be able to rise naturally towards the inlet grilles on the underside of the cooker hood and the cooker hood should be positioned away from doors and windows, which will create turbulence. € Ducting • If the room where the hood is to be used contains a fuel-burning appliance such as a central heating boiler then its flue must be of the room sealed or balanced flue type. € If other types of flue or appliances are fitted ensure that there is an adequate supply of fresh air to the room. Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being fitted, if not larger. [. . . ] 3 and attach using four Ø10mm nuts and bolts; ensuring the bolts as sleeved between the plasterboard and the joist supports to prevent the ceiling being damaged when the bolts are tightened up. If the ceiling is concrete, use eight Ø 10 mm steel rawl bolts. 650 mm when fitting above an electric hotplate and 700 mm when fitting above a gas hotplate. 5 & 6 and fix the metal diffuser to the frame of the chimney brackets using the height 5 x 10T hexagonal headed screws. A drawing on the drill gauge defines the positioning for the controls. € DUCTING The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible utilise rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Fit the non-return backflow flaps C over the round outlet item 6 on top of the canopy while pressing down until they snap into position, and then connect the ducting 150mm (6 INS) and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. 6c - item 7a) when installing the ducting version and secure the chimney stacks to the brackets using the M4 screws provided. Fit the recirculation spigot R onto the chimney bracket using the same fixing screws Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape (Fig. Make the electrical connection as described in the section titled ELECTRICAL. 6c - item 7a) when installing the recirculation version and secure the chimney stacks to the brackets using the M4 screws provided. Insert the charcoal filter into the base of the motor housing and secure the filter with two securing straps A as illustrated Fig. Decreases the suction speed: V3 → V2 → V1 Increases the suction speed: V1 → V2 → V3 Activates the intensive speed from any previously selected speed. By pressing the same touch control once again or by switching off the motor this function can be deactivated. Intensive speed has been timed at 10 minutes: H appears on the display and a spot down on the right side flashes once a second. After 10 minutes the system activates automatically the latest selected speed. [. . . ] Do not replace with any other type of lamp and do not fit a lamp with a higher rating. 7 GUARANTEE AND AFTER SALES SERVICE • In the event of any malfunction or anomaly, notify your fitter who will have to check the appli- 10 GB ance and its connection. € In the event of damage to the mains supply cable, this can only be replaced by at approved repair centre appointed by the manufacturer who have the necessary tools and equipment to carry out any repairs properly. Should these warnings fail to be observed it could affect the safety of your cooker hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN VISTA 900 6056000 IX




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN VISTA 900 6056000 IX will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.