User manual ROBLIN ODALIA VERRE NOIR DIMENSIONS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN ODALIA VERRE NOIR. We hope that this ROBLIN ODALIA VERRE NOIR user guide will be useful to you.


ROBLIN ODALIA VERRE NOIR DIMENSIONS: Download the complete user guide (59 Ko)

Manual abstract: user guide ROBLIN ODALIA VERRE NOIRDIMENSIONS

Detailed instructions for use are in the User's Guide.

[. . . ] 04 mbar to prevent the fumes from combustion being drawn back into the room. The appliance is for domestic use only and should not be operated by children or people who are infirm without supervision. This appliance must be positioned so that the wall socket is accessible. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. [. . . ] 7) Ducting: The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible use rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Place the anti-backflow flats item 8 over the round outlet item 6 and connect the ducting 150mm (6 INS) over the round outlet on top of the canopy and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws (Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. It is available to stop the boost speed before the count down of the preset stop of the hood by pressing the led button 5. Pre-set stop for the hood : This function allows you to program the cooker hood to automatically stop cooking after a pre-set period. The lights and the fan motor should be switched `OFF' to set the timer. Indication of saturation of the metal grease filters : After 200 hours use, one quick flash of the LED 1 will indicate that you must clean the metal grease filters. To reset the 200 hours timer back to zero requires the motor and lights must be switched `OFF'; then and proceed as follows: Press the LED button `+' for 3 to 4 seconds and the LED lights 1, 2, 3, 4 and 5 will flash to confirm the programme has been reset to zero. Indication of saturation of the active charcoal filter : After 400 hours use, two quick flash of the LED 1 will indicate that you must replace the active charcoal filter and clean the metal grease filters. Two flashes of the LED lights 1, 2, 3, 4 and 5 = function is switched `ON'. To use the cooker hood with a remote control re-programme the hood as follows: Press the LED button (Lighting) `1' while the motor and lights are switched `OFF', until the LED lights 1 will flash to confirm the programme has been activated : One flash of the LED lights 1 = function is switched `OFF'. Setup Process Modification: How to adjust the internal microprocessor data to suit the type of motor fitted to this appliance and the supply frequency of 50 or 60 Hz. 3 - Reconnect the mains supply while pushing the button 0/1 MOTOR for at least 2 seconds. 4 - Release the button 0/1 MOTOR (the Leds flash for about 3 seconds : capacity's confirmation SETUP PROCESS). [. . . ] Comply with local rules and regulations with regard to the extraction of ventilated air. lighting : If the lamp fails to function check to ensure it is fitted correctly into the holder. If lamp failure has occurred then it should be replaced with identical replacement. Do not replace with any other type of lamp and do not fit a lamp with a higher rating. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN ODALIA VERRE NOIR




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN ODALIA VERRE NOIR will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.