User manual ROBLIN LINEAR 900 CENTRALE DIMENSIONS

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN LINEAR 900 CENTRALE. We hope that this ROBLIN LINEAR 900 CENTRALE user guide will be useful to you.


ROBLIN LINEAR 900 CENTRALE DIMENSIONS: Download the complete user guide (51 Ko)

Manual abstract: user guide ROBLIN LINEAR 900 CENTRALEDIMENSIONS

Detailed instructions for use are in the User's Guide.

[. . . ] â· When the cooker hood is used in conjunction with other appliances supplied with energy other than electricity, the negative pressure in the room must not exceed 0. 04 mbar to prevent the fumes from combustion being drawn back into the room. â· The appliance is for domestic use only and should not be operated by children or people who are infirm without supervision. â· This appliance must be positioned so that the wall socket is accessible. [. . . ] When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible use rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Place the anti-backflow flats item 8 over the round outlet item 6 and connect the ducting 150mm (6 INS) over the round outlet on top of the canopy and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. 1 - item 7a & b) first byexpanding the chimneys slightly to allow them to clamp around the bracket item 2 and secure the Chimney stacks to the brackets using the two M4 screws item 12c provided. Fit the lower chimney sections by expanding the chimneys slightly to allow them from the top of the canopy to clamp around the upper chimney sections. Fit the recirculation spigot R onto the upper chimney wall bracket using the same fixing screws (Fig. Connect the ducting 150mm (6 INS) not provided between motors item 6 and the recirculation spigot and secure the connections with appropriate clamping rings or adhesive tape. While the 5 minutes timer is running, the indication of saturation of the filters is switched `OFF'. If a pre-set stop for the hood is switched `ON' and the 5 minutes timer is still running, the boost speed will be switched `OFF' together with the pre-set stop for the hood after the count down of 5, 10 or 15 minutes. It is available to stop the boost speed before the count down of the preset stop of the hood by pressing the led button 5. â· Pre-set stop for the hood : This function allows you to program the cooker hood to automatically stop cooking after a pre-set period. The lights and the fan motor should be switched `OFF' to set the timer. â· Indication of saturation of the metal grease filters : After 200 hours use, one quick flash of the LED 1 will indicate that you must clean the metal grease filters. To reset the 200 hours timer back to zero requires the motor and lights must be switched `OFF'; then and proceed as follows: Press the LED button `+' for 3 to 4 seconds and the LED lights 1, 2, 3, 4 and 5 will flash to confirm the programme has been reset to zero. After 400 hours use, two quick flash of the LED 1 will indicate that you must replace the active charcoal filter and clean the metal grease filters. Two flashes of the LED lights 1, 2, 3, 4 and 5 = function is switched `ON'. To use the cooker hood with a remote control re-programme the hood as follows: Press the LED button (Lighting) `1' while the motor and lights are switched `OFF', until the LED lights 1 will flash to confirm the programme has been activated : One flash of the LED lights 1 = function is switched `OFF'. Caution, the remote control handset must be fitted with standard LR03-AAA size 1. [. . . ] The grease filters should be cleaned once a month or more frequently if the hood is used for more than 3 hours per day. The filter should be replaced at least every three months or more frequently if the hood is used for more than three hours per day. Your product is designed and manufactured with high quality materials and components, which can be recycled and reused. please inform yourself about the local separate collection system for electrical and electronic product. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN LINEAR 900 CENTRALE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN LINEAR 900 CENTRALE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.