User manual ROBLIN EVASION MURALE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN EVASION MURALE. We hope that this ROBLIN EVASION MURALE user guide will be useful to you.


ROBLIN EVASION MURALE : Download the complete user guide (2851 Ko)

Manual abstract: user guide ROBLIN EVASION MURALE

Detailed instructions for use are in the User's Guide.

[. . . ] Ensure the kitchen is fitted with an airbrick, which should have a cross-sectional measurement equivalent to the diameter of the ducting being fitted, if not larger. The ducting system for this cooker hood must not be connected to any existing ventilation system, which is being used for any other purposes or to a mechanically controlled ventilation ducting. The ducting used must be made from fire retardant materials and the correct diameter must be used, as incorrect sized ducting will affect the performance of this cooker hood. When the cooker hood is used in conjunction with other appliances supplied with energy other than electricity, the negative pressure in the room must not exceed 0. [. . . ] Splashback (optional): When a splashback is to be fitted, the distance between the hood and the cooking appliances will be determined by the height of the splashback item B and whether or not there is a raised back on the worktop. If the splashback is to be fixed to the wall using both the top and bottom fixing holes, Care must be taken to ensure that the splashback is fitted at the correct height before fixing the base units or at least the worktop covering them. As this is a complex operation, it should only be undertaken by the technician installing the kitchen units or by a competent person who knows the final dimensions of the units. 4) Fixing the canopy: Before starting to fix the canopy it will be necessary to adjust the support brackets by turning the adjustment screws Vr in a clockwise direction until their reach their limit (Fig. Level the hood by turning the adjustment screws and then locking the screws 1. 5) Ducting: The hood is more effective when used in the extraction mode (ducted to the outside). When the cooker hood is ducted to the outside, charcoal filters are not required. The ducting used must be 150 mm (6 INS), rigid circular pipe and must be manufactured from fire retardant material, produced to BS. Wherever possible use rigid circular pipe which has a smooth interior, rather than the expanding concertina type ducting. Please note ducting components and ducting kits are optional accessories and have to be ordered, they are not automatically supplied with the chimney hood. Place the anti-backflow flats item 8 over the round outlet item 6 and connect the ducting 150mm (6 INS) over the round outlet item 6 on top of the canopy and secure the connections with appropriate clamping rings or adhesive tape (Fig. Before fitting the chimney to the canopy make the electrical connection as described in the section titled ELECTRICAL. When the electrical connection has been made, test the lights and the fan motor. 5 - Item 7a) and hook them behind the brackets item 2 making sure that they are well seated. 5 - Item 7b) and hook them between the upper chimey stack and the wall, making sure that they are well seated. Fit the recirculation spigot bracket item 4 onto the upper chimney wall bracket using the same fixing screws (Fig. Put the spigot item R into the spigot bracket item 4· insert the connection extension pieces laterally item G in the spigot. Make sure that the outlet of the extension pieces item G is horizontally and vertically aligned with the chimney outlets. [. . . ] If lamp failure has occurred then it should be replaced with identical replacement. Do not replace with any other type of lamp and do not fit a lamp with a higher rating. In the event of any malfunction or anomaly, notify your fitter who will have to check the appliance and its connection. In the event of damage to the mains supply cable, this can only be replaced by at approved repair centre appointed by the manufacturer who will have the required tools and equipment to carry out any repairs properly. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN EVASION MURALE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN EVASION MURALE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.