User manual ROBLIN CYLINDRE/2 - 5029007

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN CYLINDRE/2 - 5029007. We hope that this ROBLIN CYLINDRE/2 - 5029007 user guide will be useful to you.


ROBLIN CYLINDRE/2 - 5029007 : Download the complete user guide (2295 Ko)

Manual abstract: user guide ROBLIN CYLINDRE/2 - 5029007

Detailed instructions for use are in the User's Guide.

[. . . ] The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. When the cooker hood is used in conjunction with appliances supplied with energy other than electric, the negative pressure in the room must not exceed 0, 04 mbar to prevent fumes being drawn back into the room by the cooker hood. € In the event of damage to the power cable, it must be replaced by the manufacturer or by the technical service department, in order to prevent any risks. € If the instructions for installation for the gas hob specify a greater distance specified above, this has to be taken into account. [. . . ] EN 1 16 PREPARATION OF THE FRAME FOR THE HOOD IN RECYCLING VERSION In case the hood is used in recycling version it is necessary to prepare the frame with all the necessary connection pieces. In order to make the installation easier it is necessary to lengthen the frame: • Unscrew the two screws 2. € Unscrew the four safety screws placed at the top in the frame separation area. € Unscrew the eight metric screws connecting the two columns, placed on both sides of the frame (B). Installation of components in recycling version: • Fix the recycling air outlet piece 15 to the upper part of the frame using four 12c screws supplied with the hood. € Fix the flange (ø120) 10 to the lower part of the recycling air outlet 15. In order to calculate the height of the pipe it is necessary to estimate the height of the hood (mm) and subtract 615 mm. Make sure that the height of the frame is correct considering the height of the cooker hood (H frame = H hood – 184). Adjust the height of the frame and tighten again the earlier removed screws. Tighten again the safety screws in order to give more stability to the structure. A B 12c 15 10 EN 1 17 FIXING THE FRAME • Lift the frame up, making sure that the index over the frame plate is turned forwards. € Fit the frame slots onto the two screws inserted in the ceiling as above, and turn until reaching the centre of the adjustment slot. € Tighten the two screws and fasten the other two screws provided; before locking the screws completely, it is possible to adjust the frame by turning it, making sure that the screws do not come out of their housing in the adjustment slot. € The Frame must be securely fastened so as to support both the weight of the Hood and the stress caused by occasional axial pressure against the fitted Appliance. After fixing, make sure that the base is stable even when the Frame is subjected to lateral stress. € If the Ceiling is not strong enough in the area where the hood is to be fixed, the Installer must strengthen the area using suitable plates and counterplates anchored to resistant structures. 1 2 2 1 Connections DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120mm, the choice of which is left to the installer. € Fix the pipe in position using sufficient pipe clamps (not supplied). To install a ø 120 • To install a ø 120 mm air exhaust connection, insert the reducer flange 9 on the dumper 10a. € Fix the pipe in position using sufficient pipe clamps (not supplied). 10a ø 150 10a 9 ø 120 EN 1 18 Installing of the chimney and fixing of the hood When the hood is installed in recycling version the chimney has to be positioned with the slots upwards. When the hood is installed in ducting version it has to be positioned in the opposite way. [. . . ] Maintenance) When this is activated, it signals the Activated Charcoal Filter saturation alarm, indicating that the filter must be changed; the Metal Grease Filters must also be washed. The Activated Charcoal Filter saturation alarm comes into operation after the Hood has been working for 200 hours. Maintenance) T3 Fixed T4 Fixed S1 Fixed Flashing EN 2 20 MAINTENANCE REMOTE CONTROL (OPTIONAL) The appliance can be controlled using a remote control powered by a 1. 5 V carbon-zinc alkaline batteries of the standard LR03AAA type (not included). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN CYLINDRE/2 - 5029007




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN CYLINDRE/2 - 5029007 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.