If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual ROBLIN CUBIX CENTRALE 600. We hope that this ROBLIN CUBIX CENTRALE 600 user guide will be useful to you.


ROBLIN CUBIX CENTRALE 600 : Download the complete user guide (1359 Ko)

Manual abstract: user guide ROBLIN CUBIX CENTRALE 600

Detailed instructions for use are in the User's Guide.

[. . . ] If the extractor is used in conjunction with non-electrical appliances (e. Gas burning appliances), a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas. The kitchen must have an opening communicating directly with the open air in order to guarantee the entry of clean air. [. . . ] After fixing, make sure that the base is stable even when the Frame is subjected to lateral stress. If the Ceiling is not strong enough in the area where the hood is to be fixed, the Installer must strengthen the area using suitable plates and counterplates anchored to resistant structures. DUCTED VERSION AIR EXHAUST SYSTEM When installing the ducted version, connect the hood to the chimney using either a flexible or rigid pipe ø 150 or 120mm, the choice of which is left to the installer. Attach the adhesive Novastik gasket 13 to the air outlet connection 15 and fix this to the upper frame using the 2 knobs 24. Fix the air outlet connection extension piece 14 to the air outlet connection 15. Place the upper chimney section and fix the upper part to the the Fixing Part of the Upper Chimney using the 4 screws 12c (2, 9 x 9, 5) provided. recirculation version · It is necessary to make sure that the air outlet connection 15 is placed correctly so that the air outlet grid in it corresponds to that of the chimney. If the grids of the two parts are not corresponding to each other, it will be necessary to remove the chimney and to adjust the position of the air outlet connection 15, and at last to assembly the parts again by following the earlier indications. Before fixing the hood body to the frame: · From below, use the 4 screws 12f (M6 x 10) provided to fix the hood body to the frame. Connect the Hood to the mains power supply, inserting a twopole cut-out switch with contact aperture of at least 3 mm along the line. Pull the Comfort Panel to open it, ensure that the supply cable connector is properly inserted into the Suction device socket · The hood can be switched on pushing directly onto the requested speed without firstly having to select 0/1 button. It allows a suction level of 100 m3/h with a noise level of just 28dB(A). Can be enabled at any speed and is disabled by pressing the button briefly. The function becomes active when the button is pushed for about 2 seconds. [. . . ] Replace the Support, fixing it in place with the two screws removed as above. The symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ROBLIN CUBIX CENTRALE 600




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual ROBLIN CUBIX CENTRALE 600 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.