User manual PHILIPS BT136

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PHILIPS BT136. We hope that this PHILIPS BT136 user guide will be useful to you.


PHILIPS BT136 : Download the complete user guide (52 Ko)

Manual abstract: user guide PHILIPS BT136

Detailed instructions for use are in the User's Guide.

[. . . ] Philips Semiconductors Product specification Triacs BT136 series GENERAL DESCRIPTION Glass passivated triacs in a plastic envelope, intended for use in applications requiring high bidirectional transient and blocking voltage capability and high thermal cycling performance. Typical applications include motor control, industrial and domestic lighting, heating and static switching. QUICK REFERENCE DATA SYMBOL PARAMETER BT136BT136BT136Repetitive peak off-state voltages RMS on-state current Non-repetitive peak on-state current MAX. UNIT 500 500F 500G 500 4 25 600 600F 600G 600 4 25 800 800F 800G 800 4 25 VDRM IT(RMS) ITSM V A A PINNING - TO220AB PIN 1 2 3 tab DESCRIPTION main terminal 1 PIN CONFIGURATION tab SYMBOL T2 main terminal 2 gate main terminal 2 1 23 T1 G LIMITING VALUES Limiting values in accordance with the Absolute Maximum System (IEC 134). [. . . ] Maximum permissible rms current IT(RMS) , versus mounting base temperature Tmb. BT136 1000 ITSM / A BT136 IT T ITSM 12 10 time IT(RMS) / A Tj initial = 25 C max 100 dIT /dt limit 8 6 4 T2- G+ quadrant 2 10 10us 100us 1ms T/s 10ms 100ms 0 0. 01 0. 1 1 surge duration / s 10 Fig. 2. Maximum permissible non-repetitive peak on-state current ITSM, versus pulse width tp, for sinusoidal currents, tp 20ms. Fig. 5. Maximum permissible repetitive rms on-state current IT(RMS), versus surge duration, for sinusoidal currents, f = 50 Hz; Tmb 107°C. VGT(Tj) VGT(25 C) 30 25 20 15 10 5 0 ITSM / A BT136 1. 6 IT T I TSM time BT136 1. 4 1. 2 1 0. 8 0. 6 0. 4 -50 Tj initial = 25 C max 1 10 100 Number of cycles at 50Hz 1000 0 50 Tj / C 100 150 Fig. 3. Maximum permissible non-repetitive peak on-state current ITSM, versus number of cycles, for sinusoidal currents, f = 50 Hz. Fig. 6. Normalised gate trigger voltage VGT(Tj)/ VGT(25°C), versus junction temperature Tj. August 1997 3 Rev 1. 200 Philips Semiconductors Product specification Triacs BT136 series 3 2. 5 2 1. 5 1 0. 5 IGT(Tj) IGT(25 C) BT136 T2+ G+ T2+ GT2- GT2- G+ 12 10 IT / A Tj = 125 C Tj = 25 C Vo = 1. 27 V Rs = 0. 091 ohms BT136 typ max 8 6 4 2 0 0 -50 0 50 Tj / C 100 150 0 0. 5 1 1. 5 VT / V 2 2. 5 3 Fig. 7. Normalised gate trigger current IGT(Tj)/ IGT(25°C), versus junction temperature Tj. IL(Tj) IL(25 C) Fig. 10. Typical and maximum on-state characteristic. 3 2. 5 TRIAC 10 Zth j-mb (K/W) BT136 unidirectional bidirectional 1 2 1. 5 1 0. 5 0 -50 0. 01 10us 0. 1ms 1ms 10ms tp / s 0. 1s 1s 0. 1 P D tp t 0 50 Tj / C 100 150 10s Fig. 8. Normalised latching current IL(Tj)/ IL(25°C), versus junction temperature Tj. IH(Tj) IH(25C) Fig. 11. Transient thermal impedance Zth j-mb, versus pulse width tp. dVcom/dt (V/us) off-state dV/dt limit BT136. . . G SERIES BT136 SERIES 3 2. 5 2 1. 5 1 0. 5 TRIAC 1000 100 BT136. . . F SERIES 10 dIcom/dt = 5. 1 A/ms 3. 9 50 3 2. 3 1. 8 100 1. 4 150 0 -50 0 50 Tj / C 100 150 1 0 Tj / C Fig. 9. Normalised holding current IH(Tj)/ IH(25°C), versus junction temperature Tj. Fig. 12. Typical commutation dV/dt versus junction temperature, parameter commutation dIT/dt. The triac should commutate when the dV/dt is below the value on the appropriate curve for pre-commutation dIT/dt. August 1997 4 Rev 1. 200 Philips Semiconductors Product specification Triacs BT136 series MECHANICAL DATA Dimensions in mm Net Mass: 2 g 4, 5 max 10, 3 max 1, 3 3, 7 2, 8 5, 9 min 15, 8 max 3, 0 max not tinned 3, 0 13, 5 min 1, 3 max 1 2 3 (2x) 2, 54 2, 54 0, 9 max (3x) 0, 6 2, 4 Fig. 13. Epoxy meets UL94 V0 at 1/8". August 1997 5 Rev 1. 200 Philips Semiconductors Product specification Triacs BT136 series DEFINITIONS Data sheet status Objective specification Product specification Limiting values Limiting values are given in accordance with the Absolute Maximum Rating System (IEC 134). Stress above one or more of the limiting values may cause permanent damage to the device. [. . . ] This data sheet contains target or goal specifications for product development. Preliminary specification This data sheet contains preliminary data; supplementary data may be published later. LIFE SUPPORT APPLICATIONS These products are not designed for use in life support appliances, devices or systems where malfunction of these products can be reasonably expected to result in personal injury. Philips customers using or selling these products for use in such applications do so at their own risk and agree to fully indemnify Philips for any damages resulting from such improper use or sale. August 1997 6 Rev 1. 200 This datasheet has been download from: www. datasheetcatalog. com Datasheets for electronics components. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PHILIPS BT136




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PHILIPS BT136 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.