User manual PANASONIC S-140MU1E5A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC S-140MU1E5A. We hope that this PANASONIC S-140MU1E5A user guide will be useful to you.


PANASONIC S-140MU1E5A : Download the complete user guide (36611 Ko)

You may also download the following manuals related to this product:

   PANASONIC S140MU1E5A (4067 ko)

Manual abstract: user guide PANASONIC S-140MU1E5A

Detailed instructions for use are in the User's Guide.

[. . . ] INDOOR UNIT S-22MU1E5A S-28MU1E5A S-36MU1E5A S-45MU1E5A S-56MU1E5A S-60MU1E5A S-36MT2E5A S-45MT2E5A S-56MT2E5A Ceiling (T2 type) 4-Way Cassette (U1 type) 4-Way Cassette (U1 type) ENGLISH S-73MU1E5A S-90MU1E5A S-106MU1E5A S-140MU1E5A S-160MU1E5A Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 34 ~ 41 42 ~ 49 50 ~ 57 58 ~ 65 66 ~ 73 74 ~ 81 TALIANO NEDERLANDS PORTUGUÊS EΛΛΗΝΙΚΆ ● Connectable outdoor unit lineup This booklet is the operating instructions for indoor unit. Regarding the outdoor unit, see the operating instructions supplied with the outdoor unit. Indb 1 2013-12-17 17:57:32 Thank you for purchasing this Panasonic product. [. . . ] ) Each unit must be properly grounded with a ground (or zz earth) wire or through the supply wiring. Zz Operation Preparation Turn the power mains on 5 hours before the start of operation. Zz ON NOTE Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time. Indb 4 2013-12-17 17:57:36 Names of Parts INDOOR UNIT Water drain Air outlet duct * Bolt anchor * Suspension bolt * Ceiling panel (optional) Air outlet (4 locations) Air intake grille (air intake) * Field supplied Indoor unit Ceiling material * Air-outlet grille * U1 type (4-Way Cassette) Air outlet F2 type (Low Silhouette Ducted) E NGLISH Water drain Air intake grille (air intake) T2 type (Ceiling) Optional Wireless Remote Controller Model No. CZ-RTC3 For all indoor units Read the operating instructions included with the Remote Controller. Operation Mechanism „ Heating performance z Since this air conditioner utilizes outside air for heating, its heating performance deteriorates as outside temperature decreases. (Due to heat pump system) →In that case, use another heating appliance. Z This appliance may start defrosting operation to melt frost formed in the outdoor unit. 1Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow). „ ‘‘DRY’’ operation „ Defrosting z Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically. Z When the outdoor unit is turned off, the indoor unit fan will stop, too. (To prevent the humidity in the room from rising again) z When the room temperature is more likely to reach the level that was set, the fan speed is set to ‘‘breeze’’ (light wind) automatically. Z ‘‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less. 2Heating operation resumes after several minutes: The indoor unit fan remains stopped (or it will run at a very slow speed) until the indoor heat exchanger coil warms up sufficiently. „ Should the power failure occurs while the unit is running When the unit automatically resumes operation after temporary power failure, it uses the same settings before the power was cut off. Indb 5 2013-12-17 17:57:39 Adjusting Airflow Direction This section is described in the instruction manual supplied with the timer remote contoller (CZ-RTC2). Regarding the High-spec Wired Remote Controller (CZ-RTC3), refer to the Operating Instructions supplied with the model CZ-RTC3. Adjusting the upward and downward motion of airflow direction (U1 and T2 types only) „„Using the timer remote controller Press Airflow direction display /   to select your desired airflow direction. „„Flap swing motion Pressing the button during zz swing operation can stop the flap at the desired position. Display when swing operation is stopped Fan and heating Cooling and drying “FLAP” button (5 levels) (3 levels) „„Using the wireless remote controller „„Flap fixed (5 levels) Airflow direction display “FLAP” button Recommended vertical airflow direction Set zz the flap to the downward position for heating operation. (Otherwise, electric shock or injury may result because the fan is rotating at high speed. (This may damage the internal components and cause an electric shock hazard. [. . . ] Zorg voor een apart stopcontact voor elke unit en zorg ervoor dat conform de regelgeving voor elektrische bedrading er volledige ontkoppeling, dat wil zeggen een ontkoppeling van het stopcontact in alle polen, wordt geïmplementeerd in de vaste bedrading. ) Elke zz unit moet correct geaard zijn met een aardedraad of via de bedrading van de stroomtoevoer. „ Als er een stroomstoring optreedt terwijl de unit in werking is Wanneer de unit automatisch weer begint te werken na een tijdelijke stroomstoring, zullen dezelfde instellingen worden gebruikt als voor de stroomstoring. Model CZ-RWSU2 (Tipe U1) CZ-RWST3 (Tipe T2) CZ-RWSC3 (Untuk semua unit dalam ruang) Pengendali Jarak Jauh Pewaktu No. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S-140MU1E5A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S-140MU1E5A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.