User manual PANASONIC S-106MK1E5A

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual PANASONIC S-106MK1E5A. We hope that this PANASONIC S-106MK1E5A user guide will be useful to you.


PANASONIC S-106MK1E5A : Download the complete user guide (4043 Ko)

Manual abstract: user guide PANASONIC S-106MK1E5A

Detailed instructions for use are in the User's Guide.

[. . . ] For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning or servicing. Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency. 98 Product Information If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet. [. . . ] Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation. For business users in the European Union If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information. [Information on Disposal in other Countries outside the European Union] These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal. Note for the battery symbol (bottom two symbol examples): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. CZ-RTC3 For all indoor units Read the operating instructions included with the Remote Controller. Operation Mechanism Heating performance Since this air conditioner utilizes outside air for heating, its heating performance deteriorates as outside temperature decreases. (Due to heat pump system) →In that case, use another heating appliance. This appliance may start defrosting operation to melt frost formed in the outdoor unit. 1Defrosting starts: The indoor unit fan stops (or the speed becomes extremely slow). €‘DRY’’ operation Defrosting Once the room temperature reaches the level that was set, the outdoor unit repeats the cycle of turning on and off automatically. When the outdoor unit is turned off, the indoor unit fan will stop, too. (To prevent the humidity in the room from rising again) When the room temperature is more likely to reach the level that was set, the fan speed is set to ‘‘breeze’’ (light wind) automatically. €‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less. 2Heating operation resumes after several minutes: The indoor unit fan remains stopped (or it will run at a very slow speed) until the indoor heat exchanger coil warms up sufficiently. Should the power failure occurs while the unit is running When the unit automatically resumes operation after temporary power failure, it uses the same settings before the power was cut off. Indb 5 2013/11/29 14:35:31 Adjusting Airflow Direction This section is described in the instruction manual supplied with the timer remote contoller (CZ-RTC2). Regarding the high-spec wired remote controller (CZ-RTC3), refer to the Operating Instructions supplied with the model CZ-RTC3. Adjusting the upward and downward motion of airflow direction Using the timer remote controller Press Airflow direction display / to select your desired airflow direction. Flap swing motion Pressing the button during swing operation can stop the flap at the desired position. Display when swing operation is stopped Fan and heating “FLAP” button Cooling and drying (5 levels) (3 levels) Using the wireless remote controller Flap fixed (5 levels) Airflow direction display “FLAP” button Recommended vertical airflow direction Set the flap to the downward position for heating operation. [. . . ] Begitu unit luar ruang dimatikan, kipas unit dalam ruang juga akan berhenti. 2Operasi pemanasan dilanjutkan setelah beberapa menit: Kipas unit dalam ruang tetap Jika daya gagal selama unit beroperasi berhenti (atau berjalan sangat lambat) sampai kumparan penukar panas dalam ruang cukup hangat. Indb 94 2013/11/29 14:36:37 Menyesuaikan arah aliran udara untuk beberapa unit dalam ruang (khusus pengendali jarak jauh pewaktu) Selama pengoperasian beberapa unit dalam ruang lewat 1 pengendali jarak jauh, arah aliran udara dapat disesuaikan untuk masing-masing unit satu per satu atau semua sekaligus. Mis) 1 unit luar ruang mis) 2 unit luar ruang dan 8 unit dalam dan 4 unit dalam ruang ruang Tidak muncul Tidak muncul pesan pesan 1-1 1-2 1-3 1-1 1-2 1-3 1-4 2-1 Tekan 1-4 Tombol "KELOPAK" Tombol "UNIT" Maksimal ada 8 unit dalam ruangan yang dapat dihubungkan. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE PANASONIC S-106MK1E5A




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual PANASONIC S-106MK1E5A will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.