User manual NEWPOL XR1760

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual NEWPOL XR1760. We hope that this NEWPOL XR1760 user guide will be useful to you.


NEWPOL XR1760 : Download the complete user guide (1194 Ko)

Manual abstract: user guide NEWPOL XR1760

Detailed instructions for use are in the User's Guide.

[. . . ] READ AND SAVE THESE INSTRUCTIONS This appliance is designed to vent cooking smoke and odors only. Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. If there is any doubt, have the electrical system of the house checked by a qualified electrician. [. . . ] The button is also used: ­ to reset the active charcoal filter timer after changing the filters (see "Cleaning and Care"). ­ to show how long the active charcoal filters have been in use (see "Operation / Filter timers"). ­ to change the number of hours counted by the active charcoal filter timer (see "Operation / Reprogramming the filter timers"). k On/Off button l Fan power selection m Delayed shut down This button activates the Delayed Shut Down feature. The fan can be set to turn off automatically after either 5 or 15 minutes. 9 Operation Turning on the fan Delayed Shut Down If odors or smoke remain in the kitchen after cooking has been completed, the Delayed Shut Down feature can be selected to allow the hood to continue running for either 5 or 15 minutes. ^ Press the Delayed Shut Down button while the fan is still running: ^ Press the On/Off button. The indicator lights. Selecting the power level Press once = 5 minute delay (left indicator lights) ^ Use the _ buttons to select the desired power level. & = increases the fan speed $ = decreases the fan speed Level "1" to "3" (green indicators) are usually sufficient for normal cooking. Intensive setting Level "4" (yellow indicator) should be used for a short period when frying or cooking food with a strong aroma. Factors such as narrow duct diameter and bends will affect this value. Level 1 operates at 40% capacity Level 2 operates at 60% capacity Level 3 operates at 80% capacity Level 4 operates at 100% capacity Press twice = 15 minute delay (left indicator lights) To cancel the Delayed Shut Down feature press the button again. Turning off the fan ^ Press the On/Off button to turn off the fan. Automatic Safety Shut Off The fan will turn off automatically 10 hours after the last button was activated. Depending on the detergent, cleaning the grease filters in a dishwasher may cause permanent discoloration of the filter surface. ^ While the filters are removed, clean any dirt or grease from the filter casing to prevent the risk of fire. When putting the grease filters back make sure that the locking clips are visible facing the cooking surface. ^ To remove the grease filters press the locking clips in towards the middle of the filter while supporting the filter so it does not fall on to the cooktop. If the filters are incorrectly installed, insert a small screwdriver into the slit along its edge to disengage it from the casing. ^ After returning the grease filters, press the grease filter button for 3 seconds to reset the timer. ^ If the grease filters are cleaned before the grease filter timer has reached its maximum, the grease filter button should be pressed for 6 seconds to reset the counter to zero. 16 Cleaning and Care Active charcoal filters The recirculation mode requires two active charcoal filters in addition to the grease filters. The active charcoal filters will be placed in the canopy above the grease filters. Replacement active charcoal filters (part # 03 284 680) can be ordered from the Miele Technical Service Department. USA 1-800-999-1360 CDN 1-800-565-6435 ^ The grease filters must be removed to access the active charcoal filters (see "Cleaning and Care / Grease filters"). ^ Insert the active charcoal filter. Before using: Program the active charcoal filter timer, see "Operation/Reprogramming the active charcoal filter timer". Replace the active charcoal filters when the active charcoal filter indicator lights. [. . . ] Do not attach the plate directly to the ceiling by using anchors, mollies or toggle bolts. 24 Electrical data All electrical work should be performed by a qualified electrician in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed. Verify that the voltage, load and circuit rating information found on the data plate (located behind the grease filters), match the household electrical supply before installing the hood. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NEWPOL XR1760




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual NEWPOL XR1760 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.