User manual LA CROSSE TECHNOLOGY WS-9018U

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS-9018U. We hope that this LA CROSSE TECHNOLOGY WS-9018U user guide will be useful to you.


LA CROSSE TECHNOLOGY WS-9018U : Download the complete user guide (2166 Ko)

You may also download the following manuals related to this product:

   LA CROSSE TECHNOLOGY WS-9018U INSTRUCTION MANUAL (2270 ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS-9018U

Detailed instructions for use are in the User's Guide.

[. . . ] WS-9018U Wireless Weather Station Instruction Manual Contents Page 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Product features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Getting started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Quick Set Up. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Setting up Activating the Sensor(s). [. . . ] Low battery indicator will appear when the batteries are near exhaustion and require replacing. When alkaline batteries are used in the weather station and the sensor(s), battery life is approximately 12 months. When changing batteries, batteries to all units should be changed at the same time to maintain optimum operation. The time and date will synchronize to the WWVB radio controlled time signal or it can be manually set to function like a normal clock. The time signal is received once daily from 0200 to 0600 hours (2 a. m. to 6 a. m. ) or if signal reception is unsuccessful in the first attempt it will try to receive the signal each hour during these times. Signal reception is also attempted each time the weather station exits the user setting mode if the time or date has been manually changed (unless the RCC feature is set to `Off'). The received time also functions as the time base of all recorded data for the weather history. During signal reception the RCC tower icon flashes on the LCD to show that reception is taking place and will remain visual once the signal is received. The WWVB radio controlled time and calendar display is based on the signal provided by the Caesium atomic clock operated by the NIST in Boulder, Colorado. In this section, the indoor temperature and indoor relative humidity is displayed. User Setting mode: To enter the user setting mode, press and hold the set key for approximately four seconds. Then each press of the set key will run through the following sequence of setting modes: · LCD contrast · 12 hour or 24 hour time format display · Time zone ±12 hours · Time adjustment: hour · Time adjustment: minute · Calendar setting: year · Calendar setting: month · Calendar setting: date · RCC (radio controlled clock) select: On/Off · Temperature display select: °C/°F · Air pressure unit select: hPa, inHg or mmHg · Relative air pressure setting · Weather history interval recording setting In the user setting mode, if no key is pressed the LCD will automatically return to the normal operation mode after 15 seconds. Alternatively press the channel key to confirm a setting and return to the normal operation mode. LCD contrast The LCD contrast levels run from 1 to 8 with the default setting contrast level at 4. Select the desired LCD contrast level for the point of placing the unit by using the `+' or `­` keys and press the set key once to enter the 12 or 24 hour time format display mode. 12 hour or 24 hour time format display The default format of the time display is set to 24 hours. Using the `+' or `­` keys, select the time format to 12 or 24 hour time display and press the set key once to enter the time zone setting mode 8 Time zone ±12 hours The default setting is 0 hours. In the time zone mode, use the `+' or `­` keys set the desired time zone for your region from the WWVB radio controlled time then press the set key once to enter the manual time adjusting mode. Time adjustment: hour To adjust the hour (hour digit is flashing), use the `+' or `­` keys to select the hour and press set key once to enter the minute mode. Time adjustment: minute To adjust the minute (minute digit is flashing), use the `+' or `­` keys to select the minute and press set key once to enter the calendar adjustment mode. Calendar setting: year To adjust the year (year digit is flashing), use the `+' or `­` keys to select the current calendar year and press set key once to enter the calendar setting month mode. Calendar setting: month To adjust the month (month digit is flashing), use the `+' or `­` keys to select the current calendar month and press set key once to enter the calendar setting date mode. [. . . ] This limited warranty begins on the original date of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product. To receive warranty service, the purchaser must contact La Crosse Technology, Ltd for problem determination and service procedures. Warranty service can only be performed by a La Crosse Technology, Ltd authorized service center. The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd's authorized service center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS-9018U




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS-9018U will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.