User manual LA CROSSE TECHNOLOGY WS-7049-MAH INSTRUCTION MANUAL

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS-7049-MAH. We hope that this LA CROSSE TECHNOLOGY WS-7049-MAH user guide will be useful to you.


LA CROSSE TECHNOLOGY WS-7049-MAH INSTRUCTION MANUAL: Download the complete user guide (579 Ko)

Manual abstract: user guide LA CROSSE TECHNOLOGY WS-7049-MAHINSTRUCTION MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] NOTE: Fog and mist will not harm your remote temperature sensor but direct rain must be avoided. To complete the set up of your indoor weather station after the 10 minutes have passed please follow the steps on pages 8 and 9. Note: The remote temperature sensor transmits a signal every 3 minutes; after the batteries have been installed, the indoor weather station will search for the signal for a duration of 5 minutes. If there is no temperature reading in the OUTDOOR LCD after 5 minutes, make sure the units are within range of each other or repeat the battery installation procedure. 4 DETAILED SET-UP GUIDE Battery Installation A. [. . . ] An arrow pointing down indicates that the air pressure is decreasing and the weather is expected to become worse or remain poor. Indoor Temperature and Humidity The current indoor relative humidity (viewed below the time) and temperature (viewed below the relative humidity) are displayed in the INDOOR LCD. Outdoor Temperature The outdoor temperature is viewed in the OUTDOOR LCD. When there is more than one remote temperature sensor unit in operation, a arrow will appear above the CH 1 2 3 area at the bottom of the LCD. This indicates which remote temperature sensor unit (1, 2 or 3) is currently displaying its data in the OUTDOOR LCD. (This feature is explained in further detail in section V--Adding Remote Temperature Sensors). Minimum and Maximum Temperature Records The WS-7049U keeps a record of the MINIMUM and MAXIMUM temperature for both the indoor and outdoor modes. The maximum recorded indoor and outdoor temperatures will be displayed in their respective areas. The maximum recorded indoor and outdoor temperatures will be displayed in their respective areas. The current indoor and outdoor temperatures will be displayed in their respective areas. B. Resetting the Minimum and Maximum Temperature Records 9 Press and hold the "MIN/MAX/RESET" button for 5 seconds to reset the minimum and maximum recorded temperatures. Adding Remote Sensors (optional) The WS-7049U is able to receive signals from 3 different remote temperature sensors. The remote temperature sensor model(s) that you choose will come with their own set of instructions. Following are some brief instructions for the basic set-up of remote temperature sensor units with the WS-7049U. These extra remote temperature sensors can be purchased through the same dealer as this unit, or by contacting La Crosse Technology directly. A TX6U will monitor temperature only, a TX3U will monitor temperature and display the temperature on its LCD, and the TX3UP will monitor the temperature via a probe for measuring soil or water temperatures. . Note: When setting up multiple units it is important to remove the batteries from all existing units in operation. Then insert batteries into all the remote temperature sensor units in numeric sequence. Transmission problems will arise if this is not done correctly and if the total time for set-up exceeds 6 minutes. It is necessary to remove the batteries from all units currently in operation. Place all remote temperature sensor units in a numeric sequential order. Follow the Detailed Set-Up Guide for programming and operating instructions. 10 B. [. . . ] Contact La Crosse Technology for repairs. 15 SPECIFICATIONS Temperature measuring range: Indoor 32°F to 139. 8°F with 0. 2°F resolution (0°C to 59. 9°C with 0. 1°C resolution) "OFL" displayed if outside this range Outdoor -21. 8°F to 157. 2°F with 0. 2°F resolution (-29. 9°C to 69. 9°C resolution) "OFL" displayed if outside this range Indoor relative humidity measuring range Indoor temperature checking interval Indoor humidity checking interval Outdoor temperature checking interval (Remote Temperature Sensor) Outdoor temperature reception (Indoor Weather Station) Transmission Range: Power Supply: Indoor Weather Station: Remote Temperature Sensor: Battery life cycle: Recommended battery type: Dimensions (L x W x H) Indoor Weather Station (without stand): Remote Temperature Sensor: 19% to 95% with 1% resolution ("- -" displayed if outside this range Every 10 seconds Every 1 minute Every 1 minute Every 5 minutes 80 feet (in open space) 2 x AA, IEC LR6, 1. 5V 2 x AA, IEC LR6, 1. 5V Approximately 12 months Alkaline 2. 95" x 0. 82" x 10. 03" (81 x 30 x 145mm) 1. 57" x 0. 9" x 5. 04" (40 x 23 x 128 mm) 16 WARRANTY INFORMATION La Crosse Technology provides a 1-year warranty on this indoor weather station. Contact La Crosse Technology immediately upon discovery of any defects covered by this warranty. Before sending the indoor weather station in for repairs, contact La Crosse Technology. The indoor weather station will be repaired or replaced with the same or similar model. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS-7049-MAH




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS-7049-MAH will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.