User manual KAZ BP 1000

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual KAZ BP 1000. We hope that this KAZ BP 1000 user guide will be useful to you.


KAZ BP 1000 : Download the complete user guide (1528 Ko)

You may also download the following manuals related to this product:

   KAZ BP 1000 (2841 ko)
   KAZ BP 1000 (4289 ko)
   KAZ BP 1000 (2228 ko)
   KAZ BP 1000 (2841 ko)
   KAZ BP 1000 (2841 ko)
   KAZ BP 1000 (4289 ko)
   KAZ BP 1000 (4289 ko)
   KAZ BP 1000 (4289 ko)
   KAZ BP 1000 (2228 ko)

Manual abstract: user guide KAZ BP 1000

Detailed instructions for use are in the User's Guide.

[. . . ] Blood pressure readings from a healthy 31-year old male, measured at 5-minute intervals Blood pressure measured in a doctor's office only provides a momentary value. Repeated measurements at home better reflect one's actual blood pressure values under everyday conditions. Moreover, many people have a different blood pressure when they measure at home, because they tend to be more relaxed than when in the doctor's office. Regular blood pressure measurements taken at home can provide your doctor with valuable information on your normal blood pressure values under actual «everyday» conditions. [. . . ] The World Health Organisation (WHO) has set up the following standard blood pressure values when measured at resting pulse. Blood pressure (mmHg) SYS = systole = upper value DIA = diastole = lower value To ensure accurate measuring results, carefully read these use instructions. People suffering from cardiac arrhythmia, vascular constriction, arteriosclerosis in extremities, diabetes or users of cardiac pacemakers should consult their doctor before measuring their blood pressure themselves, since deviations in blood pressure values may occur in such cases. If you are under medical treatment or taking any medication, please consult your doctor first. The use of this blood pressure monitor is not intended as a substitute for consultation with your doctor. Use alkaline batteries, type LR 03 (AAA) as supplied with this product. Remove the battery compartment cover (F) and insert two batteries with correct polarity (see symbol in the battery compartment (E)). They should not be disposed of in the household waste, but at appropriate collection sites or at your retailer. Key rules for accurate blood pressure measurement Always take readings at the same time of day, ideally in the morning, under the same conditions. Otherwise the device automatically turns off after 2 minutes and activates the settings made so far. If used according to the use instructions, periodic re-calibration is not required. If at any time you question the measuring accuracy, please call at 1-888-848-2572. ­­­ While measuring (during deflation of the cuff), you can hear a clicking sound with every detected heartbeat. Inflation above 320 mmHg The device works with a special deflation procedure (stepwise deflation). Model: Operation principle: Display: Measuring range: Blood pressure measurement: Laboratory accuracy: BP 1000 / BP1600 Oscillometric method Liquid Crystal Display 0­320 mmHg (cuff pressure) 40­199 / min (pulse rate) 20 mmHg (minimum diastolic value) 300 mmHg (maximum systolic value) ± 3 mmHg (cuff pressure) ± 5 % of reading (pulse rate) 11 According to AAMI-SP10 with auscultatory reference: < 5 mmHg systematic offset < 8 mmHg standard deviation Automatic Step valve 2 batteries, type LR 03 (AAA) + 10 °C to + 40 °C ­ 20 °C to + 60 °C Up to 85% RH Suitable for wrist circumference of 13 to 21 cm According to AAMI-SP10 with auscultatory reference. (Please note that a validation against intra-arterial measurements can lead to different results for devices which are calibrated against auscultatory reference. If device is not used within specified temperature and humidity ranges the technical accuracy can not be ensured. Type BF equipment Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or automated sphygmomanometers. [. . . ] If device is not used within specified temperature and humidity ranges the technical accuracy can not be ensured. Type BF equipment Blood pressure measurements determined with this device are equivalent to those obtained by a trained observer using cuff/stethoscope auscultation method, within the limits prescribed by the American National Standard, Electronic or automated sphygmomanometers. This device conforms to the following standards: DIN EN 60601-1: 3/96 «Medical electrical equipment» ­ Part 1: General requirements for safety DIN EN 1060-1: 12/95, AMD 1 09/02 «Non-invasive sphygmomanometers» ­ Part 1: General requirements DIN EN 1060-3: 9/97 «Non-invasive sphygmomanometers» ­ Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systems 12 Braun warrants this product against any defects that are due to faulty material or workmanships for a time of two years from the original date of consumer purchase. This warranty applies when used for normal household use in accordance with the use instructions and excludes the battery and damage to the product resulting from accident or misuse. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KAZ BP 1000




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual KAZ BP 1000 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.