User manual HAWKE EZE 62 ASSEMBLY AI 280 ISSUE J 12-08

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAWKE EZE 62. We hope that this HAWKE EZE 62 user guide will be useful to you.


HAWKE EZE 62 ASSEMBLY AI 280 ISSUE J 12-08: Download the complete user guide (82 Ko)

Manual abstract: user guide HAWKE EZE 62ASSEMBLY AI 280 ISSUE J 12-08

Detailed instructions for use are in the User's Guide.

[. . . ] T*** Cable Length Per Terminal -40°C (M) 80°C +65°C T** 17. 7 27. 0 31. 5 11. 0 16. 9 19. 9 6. 6 10. 1 11. 9 24. 3 37. 0 43. 7 17. 7 27. 0 31. 8 13. 3 20. 2 23. 8 0. 425 0. 555 0. 719 Connection Solutions Hawke International is a division of Hubbell Ltd. Registered Office: Mitre House, 160 Aldersgate Street, London EC1A 4DD. A member of the Hubbell Group of Companies Hawke International UK Office Oxford Street West, Ashton-Under-Lyne, Lancashire OL7 0NA. [. . . ] The breather/drain devices must be installed in their correct orientation in either the bottom face or bottom face gland plate of the enclosure. The oerating temperature raange of the enclosure is limited to that of the breather/drain device fitted. Where the customer drills cable entries they must be installed in accordance with the component certificate Baseefa 08ATEX0363U & IECEx BAS 08. 0124U and enclosure limitations, these specify a maximum clearance on the entry thread of 0. 7mm for plain holes and where adjacent cable entries are installed sufficient clearance must be maintained to allow for the fitting of sealing/retaining washers and the rotation of the cable gland hexagons, and leave a minimum of material between adjacent holes inline with the above certificate number. e) Unused entry holes shall be fitted with stopping plugs as specified in the empty enclosure certificate Baseefa08ATEX0363U. The operating temperature range of the enclosure is limited to that of the stopping plug fitted. f) The apparatus must not be modified in anyway without reference to Hawke, as this will invalidate the certification, except for EI d) and e) and TW j) and k). g) When used under dust layers, the maximum depth should be no greater than 50mm. TERMINAL WIRING (TW) a) All wiring must be carried out in accordance with the relevant code of practice and/or instructions e. g. b) The voltage and current and maximum dissipated power shown on the label must not be exceeded. c) When used as a general purpose junction box or marshalling box the circuits carrying currents 1A shall be individually protected against over current such that the protective device operates effectively at no more than 1. 45 times the current carrying capacity of the smallest conductor used in that circuit. d) Where a major portion of the terminals are carrying maximum rate current the temperature at the branching point of the conductors may exceed 70°C. Under these circumstances the installer must ensure that the limiting temperature for the cable insulation used is acceptable e. g. e) No more than one single or multi-stranded lead shall be connected to either side of any terminal unless multiple conductors have been joined in a suitable manner e. g. two conductors into a single insulated bootlace ferrule, or any method indicated on the terminal certification. The installer must ensure that the conditions of use for the terminals outlined are complied with. h) When connecting a terminal with a conductor that is below the maximum cross section area shown for the terminal, then the maximum amps / pole must be reduced in line with the maximum amps indicated for a terminal equivalent to the conductor size being fitted e. g. for a terminal that can take a maximum conductor size of 10mm² at 40 Amps, but is fitted with a 4mm² conductor then the current shall be reduced to a maximum a 22 Amps, or the rating on the junction box lid label (whichever is the lowest). Caution: Ensure that wiring does not interfere with the enclosure lid during opening and closing. [. . . ] Physical) Terminal Tightening Torque (Nm) Terminal Quantity 76 76 64 48 38 32 24 Amps 8 8 12 16 24 32 53 Terminal Quantity 20 20 19 16 13 12 9 Amps 17 17 22 29 40 53 87 Terminal Quantity 114 114 96 72 ------- Amps 7 7 10 13 ------- 0. 4 - 0. 6 0. 4 - 0. 6 0. 5 - 1. 0 0. 8 - 1. 6 1. 2 - 2. 4 2. 0 - 4. 0 4. 0 - 5. 0 Information in the table above is based on the maximum conductor size permitted for the terminal. If earth terminals are required the quantity should be taken from the Max. Physical Terminal Quantity. EZE 62 - TERMINAL CAPACITY DATA Conductor Size (mm²) Terminal Type WDU 2. 5N WDU 2. 5 WDU 4 WDU 6 WDU 10 WDU 16 WDU 35 Min. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE EZE 62




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE EZE 62 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.