User manual HAWKE EJB ENCLOSURES DATASHEET

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual HAWKE EJB ENCLOSURES. We hope that this HAWKE EJB ENCLOSURES user guide will be useful to you.


HAWKE EJB ENCLOSURES DATASHEET: Download the complete user guide (170 Ko)

Manual abstract: user guide HAWKE EJB ENCLOSURESDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] EJB Series Enclosures EJB Enclosures Stainless Steel Increased Safety Exe Dual Certified ATEX / IECEx 19 FACE A Z Y Technical Data V T INT / EXT EARTH X FACE C V MAXIMUM QUANTITY OF ENTRIES PER FACE Thread Size Box Type M16 M20 M25 M32 M40 M50 EJB EJB EJB EJB EJB EJB EJB EJB EJB EJB EJB EJB 1 2 1 2 1 2 1 2 1 2 1 2 Face A / C 6 10 6 8 3 3 2 3 2 2 0 1 Face B Face D 4 6 8 10 4 6 6 8 2 3 2 3 1 2 2 3 1 2 2 2 0 0 1 1 Increased Safety II 2 GD Exe II C Gb Extb, III C Db. [. . . ] Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1. Temperature Class and Ambient: T6 40°C, optional T5 with ambients up to 65°C. For full technical specification, see Page 32 Dimension S T V W X Y Z EJB1 Size (mm) 120 2 80. 5 96 126 96 148 EJB2 Size (mm) 150 2 90. 5 126 156 126 178 FACE D W Terminal Type Conductor Size (mm2) Min. EJB 1 EJB 2 12 12 10 7 6 1 1 18 18 15 11 9 7 Amps EJB 1 15 15 20 28 38 21 26 EJB 2 13 13 18 24 34 47 Reduced Terminal Content at Max. Amps EJB 1 EJB 2 EJB 1 EJB 2 9 9 8 6 5 11 11 10 8 6 17 17 22 29 40 17 17 22 29 40 - WDU 2. 5N WDU 2. 5 WDU 4 WDU 6 WDU 10 WDU16 BK 6 MK 6/6 0. 5 0. 5 0. 5 0. 5 1. 5 1. 5 1 1 420 550 690 550 550 550 275 420 HTB 6 0. 5 2 x 10mm2 550 3 x 6mm2 4 x 4mm2 4 x 0. 5mm2(Min) See certificate for more options 1 1 Max. Conductor Amps per Conductor Amps per Size mm2 Size mm2 Pillar Pillar 1 0. 5 1 0. 5 1 0. 75 1 0. 75 8 1 8 1 10 1. 5 10 1. 5 15 2. 5 15 2. 5 21 4 21 4 26 6 26 6 37 10 37 10 N/A 1 Notes: For Junction Box Wattage Factor and Combined Terminal Resistance, see Pages 43 & 44 The box is supplied with an integral internal / external earth stud assembly. [. . . ] The terminals listed are restricted to a minimum operating temperature of -50°C. Connection Solutions HPG01 www. ehawke. com [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE HAWKE EJB ENCLOSURES




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAWKE EJB ENCLOSURES will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.