[. . . ] Installation Manual of Room Air Conditioner
Read this manual before installation Explain sufficiently the operating means to the user according to this manual.
Necessary Tools for Installation
1. Driver 2. Hacksaw 3. Hole core drill 4. Spanner(17, 19 and 26mm) 5. Torque wrench(17mm, 22mm, 26mm) 6. Pipe cutter 7. Flaring tool 8. Knife 9. Nipper 10. Gas leakage detector or soap-and-water solution 11. Measuring tape 12. Reamer
Drawing for the installation of indoor and outdoor units
Accessory parts
more than 5cm
mo re tha n1 0cm
No. 1 2
Accessory parts
Remote controller
Number of articles
1 2 1
Optional parts for piping Mark
Parts name Non-adhesive tape Adhesive tape Saddle(L. S) with screws Connecting electric cable for indoor and outdoor Drain hose Heating insulating material Piping hole cover
R-03 dry battery
A B
3
Mounting plate
C D
4
Drain hose
1
4X50 Steel nail, cement 4X25 Screw
E F
mo re
tha
n1
0cm
5 6 7 8 9 10 11
6 4 1
G
Attention must be paid to the rising up of drain hose
A
Plastic cap
Drain-elbow Cover
Arrangement of piping directions
1
Left
Rear left Rear right Right Below
mo re tha n1 0c m
C
Cushion
4 1 1
re t mo
han
m 10c
Pipe supporting plate Connecting cable
Note:Cooling only units don't have Drain-elbow
E
D
more
than
60cm
mor e
than
15c m
The marks from A to G in the figure are the parts numbers. [. . . ] Insert from outside the room cable into left side of the wall hole, in which the pipe has already existed. Pull out the cable on the front side, and connect the cable making a loop.
When connecting the cable before installing the indoor unit
Insert the cable from the back side of the unit, then pull it out on the front side. Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws. Pull the cable slightly to make sure the cables have been properly inserted and tightened. After the cable connection, never fail to fasten the connected cable with the wiring cover. Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully. If wiring is not correct, proper operation can not be carried out and will cause defect. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. If the fuse on PC board is broken please change it with the type of T. If the fuse of outdoor unit on PC board is broken, please change it with the type of T. [. . . ] Charge according to the following list.
for 5k 7k 9k 10k 12k 13k 18k
Piping length Additional amount 5m No need 7m 40g 10m 100g Piping length 5m Additional amount No need
for 22k 24k
7m 120g 10m 300g 20m 900g
Indoor unit
Outdoor unit
A
Outdoor unit
A B B
Indoor unit
Outdoor unit
A
C
Oil trap Indoor unit
B
Max. Elevation: for 5K 7K 9K 10K 12K 13K: B=5m for 18K 22K 24K: B=10m Max. Length: for 5K 7K 9K 10K: A=7m for 12K 13K: A=10m for 18K 22K 24K: A=20m
CAUTION In case more than 5 metres oil trap C should be installed every 5~7m.
4 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE HAIER HSU-12LEK03-Y3
Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual HAIER HSU-12LEK03-Y3 will begin.