User manual GOLDSTAR LG 152-CE
DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GOLDSTAR LG 152-CE. We hope that this GOLDSTAR LG 152-CE user guide will be useful to you.
Manual abstract: user guide GOLDSTAR LG 152-CE
Detailed instructions for use are in the User's Guide.
[. . . ] 3 1. 3 SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 4 INSULATION RESISTANCE TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1. 5 LOCATIONS OF CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DISASSEMBLY INSTRUCTIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Remove 2 screws that secure the control board to base pan and air guide. Pull the control board toward yourself.
Figure 4
NOTE : Controls, wires, and capacitor are now accessible for servicing. Disconnect one housing terminal and 3 wires for the fan motor and compressor. (Refer to circuit diagram on page 26 in this manual or inside control board. )
Figure 5
--6--
2. 2 AIR HANDLING PARTS
2. 2. 1 AIR GUIDE UPPER
1. Re-install by referring to the procedures above.
Figure 11
Figure 12
Figure 13
2. 3 ELECTRICAL PARTS
2. 3. 1 OVERLOAD PROTECTOR
1. Re-install the components by referring to the removal procedure above. After discharging the unit completely, unbrace the suction and discharge pipes at the compressor connections. Discharge the capacitor by placing a 20 K resistor across the capacitor terminals. Re-install the components by referring to the removal procedure above. Re-install the components by referring to the removal procedure above. Re-install the components by referring to the removal procedure above. INSTALLATION
This air conditioner is designed with a button-down chassis so it can be easily installed in a window.
3. 1 SELECT THE BEST LOCATION
1. To prevent vibration and noise, make sure the unit is installed securely and firmly. The outside of the cabinet must extend outward for at least 10" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner. CAUTION All side louvers of the cabinet must remain exposed on the outdside of the structure. Install the unit slanted slightly so the back is slightly lower than the front (about 1/4"). Install the unit with the bottom about 30"~60" above the floor level. Figure 21
INSIDE
OUTSIDE AWNING
FENCE
COOLED AIR
HEAT RADIATION
30"-60"
ABOUT 1/4 " Over 20"
3. 2 HOW TO INSTALL
3. 2. 1 WINDOW REQUIREMENTS
INNER SILL
NOTE: All supporting parts should be secured to firm wood, masonry, or metal. This unit is designed for installation in standard double hung windows with actual opening widths of 22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 13" from the botOUTER tom of the sash to the window stool. SILL 2. If storm window presents interference, fasten a 2" wide wood strip to the inner window sill across the full INDOORS OUTDOORS width of the sill. [. . . ] NO · Connect connector to CN-DISP1 exactly.
NO
· Exchange Q01G, Q02G, Q03G, Q04G
--22--
ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING 115V ± 10% MINIMUM 103. 5V MAXIMUM 126. 5V
COMPLAINT Fan motor will not run.
CAUSE No power Power supply cord
REMEDY Check voltage at outlet. Units using slinger ring condenser fans must have 0. 22~0. 25 inch clearance to the base. If necessary, shim up the bottom of the fan motor with mounting screw(s). Check fan motor bearings; if motor shaft will not rotate, replace the motor.
Rotary switch
Wire disconnected or connection loose
Capacitor (Discharge capacitor before testing. )
Will not rotate
Fan motor runs.
Revolves on overload
Check voltage. [. . . ]