User manual GOLDSTAR HB-152CE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GOLDSTAR HB-152CE. We hope that this GOLDSTAR HB-152CE user guide will be useful to you.


GOLDSTAR HB-152CE : Download the complete user guide (7995 Ko)

Manual abstract: user guide GOLDSTAR HB-152CE

Detailed instructions for use are in the User's Guide.

[. . . ] This symbol indicates the possibility of injury or damage to property only. Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING Always install the expansion panel(s). · Improper assembly or installation may cause incorrect operation, including injury, fire, and electric shock hazards. · It may cause fire and electric shock. Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc. [. . . ] If the room temperature is not satisfactory after a reasonable time, adjust the control to a cooler or warmer setting, as appropriate. Service Manual 13 Operation Remote Control Operations CAUTION: The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Controller and the air conditioner. The controls look like this: Controls Power 1 3 7 Temp 2 Fan Speed 3 Timer Mode 4 Energy Saver Auto Swing 6 5 4 5 6 2 1 1. · When you first turn it on, the Set is on the High cool mode and the temp. Temperature Setting · This button controls the room temperature setting in a range between 60°F and 86°F in 1° increments. 10 Hours ¡ 11 Hours ¡ 12 Hours ¡ CANCLE. The set temperature will be raised by 2°F after 30 minutes and again after another 30 minutes. - Starting Operation Each press of the button cycles through the options in this order: 1 Hour ¡ 2 Hours ¡ 3 Hours ¡ 4 Hours ¡ 5 Hours ¡ 6 Hours ¡ 7 Hours ¡ 8 Hours ¡ 9 Hours ¡ 10 Hours ¡ 11 Hours ¡ 12 Hours ¡ CANCLE. 5. · Approximately every 3 minutes the fan will turn on and check the room air to determine if cooling is needed. 3. Fan Speed · Pressing the Fan Speed button toggles between Low and High speeds. 4. On/Off Timer - Stopping Operation Each press of the button cycles through the options in this order: 1 Hour ¡ 2 Hours ¡ 3 Hours ¡ 4 Hours ¡ 5 Hours ¡ 6 Hours ¡ 7 Hours ¡ 8 Hours ¡ 9 Hours ¡ 6. Cool/Fan/Dry · Everytime you push this button, it will toggle between COOL, FAN, and DRY. How to Insert Batteries 1. Re-install the components by referring to the above removal procedure. Re-install the component by referring to the above removal procedure, above. If the supply cord of this appliance is damaged, it must be replaced by the special cord. (The special cord means the cord which has the same specification marked on the supply cord attached at the unit. ) Figure 29 Figure 30 Refrigerating Cycle CAUTION: Discharge the refrigerant system using a FreonTM Recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections. After discharging the refrigerant completely, unbraze the interconnecting tube at the evaporator connections. After discharging the refrigerant completely, unbraze the interconnecting tube at the capillary tube. Re-install the component by referring to notes. NOTICE Figure 32 -- Replacement of the refrigeration cycle. When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a FreonTM recovery System. If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. [. . . ] YES · Check the RY-COMP. NO · Connect LEAD Wire to RY-COMP again. Possible Trouble 4 · Fan does not operate. Is the voltage NO. 1 or 4 of IC01M DC 5V?YES NO · Exchange IC01M. Is the voltage NO. 13 or 16 of IC01M 0V?· Check the wiring diagram. NO · Exchange IC01M. 30 Room Air Conditioner Troubleshooting Guide Possible Trouble 5 · Romote controller does not operate. Is the voltage of Battery about over 2. 3V?YES NO · Exchange the battery. NO · Check the P. W. B pattern. Is the connection of CN-DISP1 all right? [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GOLDSTAR HB-152CE




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GOLDSTAR HB-152CE will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.