User manual GATEWAY PJ-G210 INSTALLATION GUIDE

DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Diplodocs provides you a fast and easy access to the user manual GATEWAY PJ-G210. We hope that this GATEWAY PJ-G210 user guide will be useful to you.


GATEWAY PJ-G210 INSTALLATION GUIDE: Download the complete user guide (288 Ko)

Manual abstract: user guide GATEWAY PJ-G210INSTALLATION GUIDE

Detailed instructions for use are in the User's Guide.

[. . . ] step 3, page 5 Threaded Rod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . step 4, page 5 Extension Column . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6 Installation Conditions: To Wood Joist Finished Ceilings, Exposed Wood Joists, or Wood Beam Ceilings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Overtightening can cause stress damage to wood screws, greatly reducing their holding power!Tighten to 80 in · lb (9 N. M. ) maximum torque. concrete anchor CONCRETE CEILING G 1 concrete ceiling F concrete anchor Drill hole and insert anchor Illustration A 2 G F concrete anchor Place ceiling plate over anchor and secure with screw 3 FOR DIRECT ATTACHMENT TO LOAD BEARING CONCRETE ONLY!Concrete expansion anchors are not intended for attachment to concrete ceilings covered with a layer of plaster, drywall, or other finishing material. If mounting to concrete ceiling covered with plaster / drywall is unavoidable, plaster / drywall must be counterbored as shown below. INCORRECT CUTAWAY VIEW metal bracket concrete metal bracket F concrete anchor CORRECT concrete After repeating step one tighten all fasteners plaster/ dry wall plaster/ dry wall 4 of 8 Visit the Peerless Web Site at www. peerlessindustries. com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. . lush Mount Application Screw ball and socket assembly (A) into ceiling plate (G). Align the notch with one of the four holes of the ceiling plate (G) and secure ball and socket assembly (A) with a M5 x 10 mm socket pin screw (C) using security allen wrench (B) as shown in detail 1. Skip to step 6. WOOD JOIST NOTCH G C A CEILING G DETAIL 1 THREADED ROD B A 1/2 -13 THREADED ROD ACC 810 Installation to Threaded Rod Accessory ACC 810, threaded rod adapter, is required. Align slot in ACC 810 with one of the top holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector (I) into slot on ACC 810 using 4 mm security allen wrench (B). Align slot in ball and socket mount (A) to one of the bottom holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector (I) into slot in ball and socket mount (A). Skip to step 6. SLOT SLOT ACC 810 I SLOT J DETAIL 2 I THREADED ROD ACC 810 SLOT I A DETAIL 3 A J 5 of 8 Visit the Peerless Web Site at www. peerlessindustries. com ISSUED: 04-21-03 SHEET #: 055-9158-1 For customer service call 1-800-729-0307 or 708-865-8870. Installation to Extension Column Screw extension column to ceiling plate (G). Align the notch with one of the four holes in the ceiling plate (G) and secure extension column with a M5 x 10 mm socket pin screw (C) using security allen wrench (B). Align slot in extension column with one of the top holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector (I) into slot on extension column using security allen wrench (B). Align slot in ball and socket mount (A) to one of the bottom holes in extension column connector (I). Insert and tighten one 10-32 x 3/8 socket pin screw (J) through extension column connector into slot in ball and socket mount (A) using security allen wrench (B). [. . . ] Peerless, at its sole discretion, will repair or replace such defective equipment free of charge provided the products are returned prepaid to Peerless. Unauthorized service or repairs by anyone other than authorized Peerless personnel renders this Warranty void and releases Peerless from any further responsibility or obligation. Any damage caused by failure to observe proper packing or to observe instructions for installation, by accident or in transit or elsewhere will not be covered by the Warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE GATEWAY PJ-G210




Click on "Download the user Manual" at the end of this Contract if you accept its terms, the downloading of the manual GATEWAY PJ-G210 will begin.

 

Copyright © 2015 - manualRetreiver - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.